Vent-light combination

Advertisement

Available languages

Available languages

Ve n t - L i g h t
C o m b i n a t i o n
MODEL: 668RP
WARNING: To reduce the risk of fire or electric shock,
do not use this fan with any solid-state speed control
d e v i c e .
WARNING: To reduce the risk of shock, disconnect
power before servicing.
Not for use in Kitchens.
Acceptable for use over a bathtub or shower when
installed in a GFCI protected branch circuit.
I M P O R TANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
m a n u f a c t u r e r .
B. Before servicing or cleaning unit, switch power off at
service panel and lock service panel to prevent power
from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
C A U T I O N :
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
For installation in sloped ceilings up to 12/12 pitch.
Ductwork must point up.
I N S TA LLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
F O L L O W I N G :
A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a
G F C I (Ground Fault Circuit Interrupter) protected by a branch circuit.
F. NEVER place a switch where it can be reached from a tub or shower.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
FIGURE 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 668RP and is the answer not in the manual?

Questions and answers

Summary of Contents for NuTone 668RP

  • Page 1 INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! Ve n t - L i g h t C o m b i n a t i o n MODEL: 668RP • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control d e v i c e .
  • Page 2: Mounting Fan Housing

    MOUNTING FAN HOUSING W I R I N G NEW CONSTRUCTION All wiring must comply with local and national codes and Using Hanger Bars unit must be properly grounded. Refer to Figure 1. 1. Insert hanger bars in slots provided in housing. 1.
  • Page 3 MOUNTING REFLECTOR AND GRILLE 1. Refer to Figure 3. Place reflector in the opening in the center of the grille. The notches in the reflector should fit over the pegs on either side of the opening. Insert plug from lamp socket into white receptacle on wiring c o m p a r t m e n t .
  • Page 4: Instrucciones De Seguridad Importantes

    INSTRUCCIONES DE INSTALACIÓN ¡LEA Y CONSERVE ESTAS INSTRUCCIONES! Combinación Ve n t - L i t e MODELO: 668RP • ADVERTENCIA: Para reducir el riesgo de electrocución, no use este ventilador con dispositivos de control de velocidad de estado sólido. •...
  • Page 5 INSTALACIÓN DE LA CAJA DEL C A B L E A D O VENTILADOR Todo cableado debe cumplir con los códigos nacionales y locales y la unidad debe ser puesta a tierra correctamente. CONSTRUCCIONES NUEVA S Con barras de soporte 1 .
  • Page 6 INSTALACIÓN DEL REFLECTOR Y LA REJILLA 1. Refiérase a la figura 2. Coloque el reflector en la abertura que está en el centro de la rejilla. Las clavijas que están a cada lado de la abertura deben calzar dentro de las ranuras del reflector. Enchufe la lámpara en el receptáculo que está...
  • Page 7: Parts List

    53740-000 89852 Grille and Lens Assembly 89852-000 89765 Reflector 89765-000 35758 Lamp Socket 35758-000 NuTone Attn: Parts Department 4820 Red Bank Rd. NOTE: Always order by Cincinnati, OH 45227-1599 current part number Phone: (513) 527-5426 Fax: (513) 527-5173 668RP I.I.

This manual is also suitable for:

Vent-light 668rp

Table of Contents

Save PDF