Modifying iDRAC Network Settings Using RACADM

RACADM config or getconfig commands support the -m <module> option for the following configuration
groups:
cfgLanNetworking
cfgIPv6LanNetworking
cfgRacTuning
cfgRemoteHosts
cfgSerial
cfgSessionManagement
For more information on the property default values and ranges, see the
iDRAC7 and CMC .

Configuring iDRAC VLAN Tag Settings

VLANs are used to allow multiple virtual LANs to co-exist on the same physical network cable and to segregate the
network traffic for security or load management purposes. When you enable the VLAN functionality, each network
packet is assigned a VLAN tag. VLAN tags are chassis properties. They remain with the chassis even when a
component is removed.

Configuring iDRAC VLAN Tag Settings Using Web Interface

To configure VLAN for server using the CMC Web interface:
1.
Go to any of the following pages:
In the system tree, go to Chassis Overview and click Network → VLAN .
In the system tree, go to Chassis Overview → Server Overview and click Network → VLAN . The VLAN Tag
Settings page is displayed.
2.
In the iDRAC section, enable VLAN for the server(s), set the priority and enter the ID. For more information about
CMC Online Help .
the fields, see the
3.
Click Apply to save the settings.

Configuring iDRAC VLAN Tag Settings Using RACADM

Specify the VLAN ID and priority of a particular server with the following command:
racadm setniccfg -m server-<n> -v <VLAN id> <VLAN priority>
The valid values for <n> are 1 – 16.
The valid values for <VLAN> are 1 – 4000 and 4021 – 4094. Default is 1.
The valid values for <VLAN priority> are 0 – 7. Default is 0.
For example:
racadm setniccfg -m server-1 -v 1 7
For example:
RACADM Command Line Reference Guide for
89

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS-M4110 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Chassis management controller

Table of Contents

Save PDF