Grindmaster PrecisionBrew APB-330V2 Operation And Instruction Manual

Grindmaster PrecisionBrew APB-330V2 Operation And Instruction Manual

Series 2.0 shuttle brewer & airpot/shuttle brewers

Advertisement

Shuttle
Brewer & Airpot/Shuttle
®
Operation and Instruction Manual
For Models APB-330V2, APB-430V2, APBVSA-330V2, APBVSA-430V2, APBIC-330V2,
APBIC-430V2, APB-330V2E230, APB-430V2E230, APBVSA-330V2E230,
APBVSA-430V2E230, APBIC-330V2E230, PBIC-430V2E230

Table of Contents

Warning Labels . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation and Start-up . . . . . . . . . . . . . . . . . . . 4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Error Messages . . . . . . . . . . . . . . . . . . . . . 20
Filling Problems . . . . . . . . . . . . . . . . . . . . . 20
Heating Problems . . . . . . . . . . . . . . . . . . . . 22
Brewing Problems . . . . . . . . . . . . . . . . . . . . 24
Precision Brew® Control Board . . . . . . . . . . . .26
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Parts Photos . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
VS-1.5(S) Cleaning and Sanitizing . . . . . . . . . .32
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . 33
Prior authorization must be obtained from
Grindmaster-Cecilware for all warranty claims.
PRINTED IN U.S.A.
®
Models APB-330V2/
APB-330V2E230
Models APBVSA-430V2/
Grindmaster-Cecilware
4003 Collins Lane
Louisville, KY 40245 USA
(502) 425-4776
(800) 695-4500 (USA & Canada only)
(800) 568-5715 (Technical Service Only)
FAX (502) 425-4664
www.grindmaster.com
Brewers
Models APBIC-430V2/
APBIC-430V2E230
APBVSA-430V2E230
0511 Form # AM-346-02
Part # A090-842

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PrecisionBrew APB-330V2 and is the answer not in the manual?

Questions and answers

Roosevelt Gaither
April 14, 2025

how much coffee to used in p330 1.5 gal

1 comments:
Mr. Anderson
April 15, 2025

The amount of coffee to be used for a 1.5-gallon brew in the Grindmaster PrecisionBrew APB-330V2 should follow corporate recommendations for coffee amount and grind. The exact quantity is not specified in the manual.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Grindmaster PrecisionBrew APB-330V2

  • Page 1: Table Of Contents

    Wiring Diagrams ......33 Prior authorization must be obtained from Models APBVSA-430V2/ Grindmaster-Cecilware for all warranty claims. APBVSA-430V2E230 Grindmaster-Cecilware...
  • Page 3: Warning Labels

    Warning Labels The following warning labels were on your dispenser when it was shipped from the factory. They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately. Part # A546-445 Located on front splash panel and lid of machine.
  • Page 4 Installation WARNING ELECTRIC SHOCK HAZARD! Installation of this appliance should be performed by qualified service personnel only. Improper installation could result in electrocution. Set-Up/Position 1) Remove the brewer from the packing material and attach its legs. 2) Position the brewer on a strong, stable table or counter. Check the level front to back and side to side. Adjust the legs to the correct level.
  • Page 5 Installation (cont.) Electric Hook-up The brewer is designed to operate at the specified voltage on the nameplate with a tolerance of ± 10% for voltage deviation. It is very important that the power line to the brewer be checked to make sure that the voltage is within 10% of the brewer’s rated voltage.
  • Page 6: Installation And Start-Up

    Installation (cont.) Start-up 1) Flip power supply to machine “ON” at the branch supply disconnect and allow the water tank to fill. The machine will make a subtle hissing sound while filling. Attention: A watchdog circuit monitors the fill valve “ON” time. If the “ON” time exceeds 6 minutes continuously, the brewer will display message “ER1”...
  • Page 7: Adjustments

    Adjustments All adjustments to machine are accessible through the front display(s). Refer to specifics below and the Programming Routine section. All values are preset at the factory and may vary brewer to brewer. Temperature Adjustment Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming Routine section for procedure.
  • Page 8: Programming

    Adjustments (cont.) Brew Volume “br” Brew time can be set for each size visually. See Setting Brew Volume Procedure below. Brew time can also be adjusted through the display. See Programming Routine section. Setting Brew Volume Visually 1. Remove brew basket and place container under brew head. 2.
  • Page 9 Programming (cont.) To program the following items, press the Large, Right side portion button. (refer to Table 1) Temperature Scale: Choose °F or °C Set Water Tank Temperature: Choose between 170°F - 205°F EnErGy mOdE: Choose YES or NO Ltn (Low Temp No Brew): Choose YES or NO •...
  • Page 10 Programming (cont.) By-PASS (Set bypass volume): Choose OFF to 25% Set the amount of bypass desired during brew. If none is desired then set to OFF, otherwise, set the % of brew volume to bypass. CoPY-to-LEFt: Choose YES or no If the same program parameters are desired on same portion size on the left side, then choose YES and the parameters will be copied.
  • Page 11 Programming Sequence for Large Left Portion Table 1 PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS: DISPLAY READING ADJUST ADVANCE TEMP SCALE TANK TEMP (170-202F) ENERGY MODE ENERGY MODE LOW-TEMP/NO-BREW LOW-TEMP/ NO-BREW DRIP TIME DRIP TIME PERCENT OF BREW BYPASS RATIO BREW TIME BREW TIME (.01 TO 6.00)
  • Page 12 Programming Sequence for Large Left Portion (cont.) Table 1 (cont.) DISPLAY READING ADJUST ADVANCE PRE INFUSION PRE INFUSION OFF TIME (.05 TO 2.00) PULSE BREW # OF PULSES (OFF, 1 - 10) PULSE ON PULSE ON TIME (0:05-2:00) PULSE OFF PULSE OFF TIME (0:05-2:00) BY-PASS OFF TO .25 PERCENT...
  • Page 13 Programming Sequence for Medium Portions Table 2 PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS: DISPLAY READING ADVANCE ADJUST BREW TIME BREW TIME (.01 TO 6.00) PRE INFUSION PRE INFUSION TIME (OFF TO 2.00) PRE INFUSION PRE INFUSION OFF TIME (.05 TO 2.00) PULSE BREW...
  • Page 14 Programming Sequence for Medium Portions (cont.) Table 2 (cont.) PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS: DISPLAY READING ADVANCE ADJUST COPY TO LEFT Page 14 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 15 Programming Sequence for Small Portions Table 3 PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS: DISPLAY ADJUST READING ADVANCE BREW TIME BREW TIME (.01 TO 6.00) PRE INFUSION PRE INFUSION TIME (OFF TO 2.00) PRE INFUSION PRE INFUSION OFF TIME (.05 TO 2.00) PULSE BREW...
  • Page 16: Cleaning

    Cleaning WARNING Burn Hazard! Hot liquids and surfaces are present in this equipment. To avoid burns use caution when cleaning. Rinse hot parts with cold water before cleaning. Use gloves or a heavy cloth when removing hot parts from brewer. After Each Brew: 1) Dispose of grounds and rinse brew basket.
  • Page 17: Service

    Service The rest of this manual contains information to aid the service person who is working on this equipment. This page has information on performing . Following this is the section which can help diagnose problems which are divided into three basic systems: filling, heating, and brewing. Next is an which will help in the selection of repair parts.
  • Page 18 Factory Specific Features The following sections describe features that are not intended to be used by the end user. These features, instead, are intended to help Grindmaster set up and test the machine. Factory/Field Test Menu This menu is intended to check product functionality both at the end of the factory line and in the field. The con- trol must be completely OFF (both sides) to enter field test.
  • Page 19 Factory/Field Test Menu (cont.) Step Function Operation Description LED Test All LEDs ON Verify that all LEDs turn on. Firmware Version Display firmware version Shows the software version of the control. Date Code Not used Not used EEPROM Version Not used Not used Non Resetable Unit Scroll non-resetable unit counter...
  • Page 20: Troubleshooting

    Troubleshooting The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in the order shown until the exact nature of the problem is determined. The following procedures must be performed by a qualified service technician.
  • Page 21 Troubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy Tank does not refill • No electrical power to • Check for proper • Establish electrical power equipment voltage at terminal to unit. block. Check circuit breaker on supply circuit. •...
  • Page 22: Heating Problems

    Troubleshooting (cont.) Filling Problems Problem Possible Causes Service Check Remedy Tank does not refill • Fill valve or control • Check to ensure proper • If 6 pin connector is securely board is faulty connection between attached to control board and 6 pin connector and con- all connections are secure trol board.
  • Page 23 Troubleshooting (cont.) Heating Problems Problem Possible Causes Service Check Remedy Tank does not heat • Low (long) electrode • Disconnect electrode • Remove electrode assembly coated with lime or wire at quick connect and clean the probes. If faulty. (purple wire). Connect a problem is not corrected, wire from the quick con- replace electrode assembly.
  • Page 24: Brewing Problems

    Troubleshooting (cont.) Heating Problems Problem Possible Causes Service Check Remedy Tank does not heat • Contactor faulty. • Ensure that coil on • If the contactor coil is contactor is energized energized and there is an by ensuring that there open circuit across any of is proper voltage the contactor poles, replace...
  • Page 25 Troubleshooting (cont.) Brewing Problems Problem Possible Causes Service Check Remedy Brew volume too • Sprayhead clogged. • Visually check for • Clean all holes. clogging of holes large or too small in brewhead. • Brew valves clogged • Visually inspect •...
  • Page 26 (Monday-Friday 8:00 am - 6:00 pm EST) or an authorized service center in your area. Please have the model and serial number ready so that accurate information can be given. Prior authorization must be obtained from Grindmaster-Cecilware’s Technical Services Department for all warranty claims.
  • Page 27: Parts List

    Parts List for All Precision Brew Models Models APB-330V2, APB-430V2, APBVSA-330V2, APBVSA-430V2, APBIC-330V2, APBIC-430V2 ITEM DESCRIPTION PART # Reference Front View Picture: Controller PB A530-066 Relay, Heater* A71450 Water Inlet Valve 24 VAC A725-117 Terminal Block A531-035 Spray Head APT400-105 Orifice Bypass A518-053 Retaining Pin for A518-053...
  • Page 28 Front View (refer to key on page 27) Lower Warmer (refer to key on page 27) (APB-430V2 pictured) Page 28 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 29 Top View (refer to key on page 27) Tank Lid (refer to key on page 27) Shuttle Brewers & Airpot/Shuttle Brewers Page 29...
  • Page 30 Shuttle Parts List for APB-330V2 and APB-430V2 ITEM DESCRIPTION PART # Faucet Model ES A537-053 Shank w/ Chrome Bonnet A522078 Gauge Assembly A718-018 Kit, Shuttle Lid A725-092 S.S. Shuttle Cover A713-027 (not shown)* Lid Retaining Clip A548-142 A548-140 Lid Stopper w/ O-Ring A61365 * S.S.
  • Page 31 Model VS-1.5 Vacuum Shuttle Parts List Shuttle Brewers & Airpot/Shuttle Brewers Page 31...
  • Page 32 These cleaning and sanitizing instructions are only a guideline to be used for the cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5. In-house cleaning and sanitizing methods may be more effective. Grindmaster assumes no responsibility for the food born illness and/or sickness caused by using improper sanitizing methods.
  • Page 33: Wiring Diagrams

    Wiring Diagram - Precision Brew 430 Series Models APB-430V2, APBVSA-430V2, and APBIC-430V2 Shuttle Brewers & Airpot/Shuttle Brewers Page 33...
  • Page 34 Wiring Diagram - Precision Brew 330 Series Models APB-330V2, APBVSA-330V2, and APBIC-330V2 Page 34 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 35: Wiring Diagram

    Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBIC-430V2E230 (Single or Three Phase Models) Shuttle Brewers & Airpot/Shuttle Brewers Page 35...
  • Page 36 Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Brewers Page 36 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 37 Wiring Diagram - Precision Brew 430 Series 120/208 or 120/240V Models APB-430V2, APBVSA-430V2, and APBIC-430V2 Shuttle Brewers & Airpot/Shuttle Brewers Page 37...
  • Page 38 Wiring Diagram - Precision Brew 330 Series 120/208V, 120/240V Models APB-330V2, APBVSA-330V2, and APBIC-330V2 Page 38 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 39 Wiring Diagram 230V, 208V, or 240V without Neutral Models APB-430V2, APBVSA-430V2, APBIC-430V2, APB-430V2E230, APBVSA-430V2E230, and APBIC-430V2E230 Shuttle Brewers & Airpot/Shuttle Brewers Page 39...
  • Page 40 Wiring Diagram 230V, 208V, or 240V without Neutral Models APB-330V2, APBVSA-330V2, APBIC-330V2, APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Page 40 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 41 Wiring Diagram - Heater Configuration (3 Heater) Shuttle Brewers & Airpot/Shuttle Brewers Page 41...
  • Page 42 Wiring Diagram - Heater Configuration (1 Heater) Page 42 Shuttle Brewers & Airpot/Shuttle Brewers...
  • Page 43: Control Board

    Control Board all PrecisionBrew™ V2.0 models Refers to software version number. Subject to change. Shuttle Brewers & Airpot/Shuttle Brewers Page 43...
  • Page 44: Grindmaster Corporation

    Tel (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P.O. Box 35020 • Louisville, KY 40232 • USA www.grindmaster.com • email: info@grindmaster.com © Grindmaster Corporation, 2011 0511 Form # AM-346-02 PRINTED IN USA Part # A090-842...