Standard Construction Features Model SQ Direct Drive Model BSQ Belt Drive...
Page 5
Standard Construction Features Cabinet Construction Drive Assembly Drives are sized for a minimum of 150 percent The fan housing is constructed of rigid structural of driven horsepower. Machined cast iron members and formed galvanized steel panels. pulleys are factory set to the required RPM and (Aluminum construction is optional in all SQ adjustable for final system balancing.
Page 6
Vari-Green Options ® Vari-Green Motor - Model SQ Features ® 1. Dial on Motor Control - A potentiometer (dial on Greenheck’s motor control) is mounted on the motor for easy electronically speed adjustment for system balance. Simply turn commutated (EC) the dial there are no belts and pulleys to adjust.
Page 7
Vari-Green Options ® The Vari-Green constant pressure control is pre- Demand Control Ventilation for programed and easy to install for applications that Multistory Buildings include: venting dryers, bathrooms, residential type kitchen space or industrial process exhaust. Applications requiring constant pressure or variable volume can utilize SQ fans with Vari-Green motors Contact fans@greenheck.com for more information.
Options and Accessories Aluminum Construction Coatings Aluminum construction is available for all direct drive Wide variety of coatings sizes 60-160 and belt drive sizes 70-300. Some and colors are available. drive frame components may still be of galvanized Decorative coatings construction to maintain structural integrity.
Filter Options The filter box is designed to provide a compact and convenient clean air solution. Factory-assembled as a single unit, this fan eliminates the costly process of designing, fabricating and installing special remote filter box assemblies. Both the fan and filter section feature removable access panels on both sides to remove and replace filters, making fan maintenance simple and fast.
Discharge Configurations Discharge Configuration The side discharge option helps to reduce system effect. It will increase performance and reduce Fan performance will change with different discharge installation labor. The most notable is reducing system positions. Catalog data is based on an inline effects.
Page 11
Side Discharge SQ Side Discharge BSQ Side Discharge Left Side Discharge Access Door Access Door Left Side Inline Inline Discharge Discharge Discharge Figure 4 Figure 5 Height Height Inlet Inlet Width Right Side Width Right Side Discharge Discharge SQ Side Discharge Duct Openings BSQ Side Discharge Duct Openings Unit Size Width...
Horizontal and Vertical Mounting Options All SQ and BSQ fan models can be mounted horizontally, vertically or at an angle. For ease of installation, knockouts are provided at each location where mounting brackets are shown in figures 6, 7 and 8. Optional brackets are universally adjustable to mount in any of these locations.
Base Mount or Hanging Isolators Complete isolation kits are available Standing Neoprene Isolator with either neoprene or spring isolators and are sized to match the weight of the specified fan size. The base isolator support brackets are designed to permit mounting of the fan with the motor located on top or either side.
Typical Installation Models SQ and BSQ ducted inline fans are designed both. The motor is rigidly mounted and can be oriented for the exhaust, supply or recirculation of air in a in any direction (top, bottom, side). building. Typical installation requires ductwork on the The model BSQ ducted inline fan must be installed inlet and outlet side of the fan.
BSQ 70 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) (381) (533) 1000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 76 (34) *Motor cover is optional.
Page 25
BSQ 80 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) 1000 1200 (381) (533) 1000 1500 2000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 79 (36) *Motor cover is optional.
Page 26
BSQ 90 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (302) (381) 1000 1200 1400 1600 1800 (381) (533) 1000 1500 2000 2500 3000 Damper size = 12 x 12 (305 x 305) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 84 (38) *Motor cover is optional.
Page 27
BSQ 100 - Belt Drive ⁄ (394) (356) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (352) (432) 1000 1500 2000 2500 (432) (533) 1000 2000 3000 4000 Damper size = 14 x 14 (357 x 357) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 91 (41) *Motor cover is optional.
Page 28
BSQ 120 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (403) (483) 1000 1500 2000 2500 3000 (483) (533) 1000 1500 2000 2500 3000 3500 4000 4500 5000 Damper size = 16 x 16 (406 x 406) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
Page 29
BSQ 130 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (454) (533) 1000 1500 2000 2500 3000 3500 (533) (533) 1000 2000 3000 4000 5000 Damper size = 18 x 18 (457 x 457) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 97 (44) *Motor cover is optional.
Page 30
BSQ 130HP - Belt Drive ⁄ (454) (406) 1100 1000 Density 0.075 lb/ft (25) ⁄ (318) ⁄ (454) (533) 1000 1500 2000 2500 (533) (533) 1000 1500 2000 2500 3000 3500 4000 Damper size = 18 x 18 (457 x 457) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
Page 31
BSQ 140 - Belt Drive ⁄ (454) (406) Density 0.075 lb/ft (25) ⁄ (318) ⁄ (505) (584) 1000 1500 2000 2500 3000 3500 4000 4500 (584) (559) 1000 2000 3000 4000 5000 6000 7000 Damper size = 20 x 20 (508 x 508) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
Page 32
BSQ 140HP - Belt Drive ⁄ (454) (406) 1200 Density 0.075 lb/ft 1000 (25) ⁄ (318) ⁄ (505) (584) 1000 1500 2000 2500 3000 3500 (584) (559) 1000 2000 3000 4000 5000 Damper size = 20 x 20 (508 x 508) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms).
Page 33
BSQ 160 - Belt Drive ⁄ (521) (432) Density 0.075 lb/ft (25) ⁄ (340) ⁄ (581) (660) 1000 2000 3000 4000 5000 6000 (660) (660) /hr X 1000 Damper size = 23 x 23 (584 x 584) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 208 (94) *Motor cover is optional.
Page 34
BSQ 160HP - Belt Drive ⁄ (521) (432) 1200 Density 0.075 lb/ft 1000 (25) ⁄ (340) ⁄ (581) (660) 1000 2000 3000 4000 5000 (660) (660) 2000 4000 6000 8000 Damper size = 23 x 23 (584 x 584) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 208 (94) *Motor cover is optional.
Page 35
BSQ 180 - Belt Drive ⁄ (619) (457) Density 0.075 lb/ft ⁄ (38) ⁄ (349) ⁄ (606) (711) 1000 2000 3000 4000 5000 6000 7000 (711) (711) /hr X 1000 Damper size = 24 x 24 (610 x 610) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 245 (111) *Motor cover is optional.
Page 36
BSQ 180HP - Belt Drive ⁄ (619) (457) Density 0.075 lb/ft ⁄ (38) ⁄ (349) ⁄ (606) (711) 1000 2000 3000 4000 5000 6000 (711) (711) /hr X 1000 Damper size = 24 x 24 (610 x 610) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 245 (111) *Motor cover is optional.
Page 37
BSQ 200 - Belt Drive (711) (508) Density 0.075 lb/ft ⁄ (38) (406) ⁄ (708) (813) 1000 2000 3000 4000 5000 6000 7000 8000 (813) (813) /hr X 1000 Damper size = 28 x 28 (711 x 711) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 314 (142) *Motor cover is optional.
Page 38
BSQ 200HP - Belt Drive (711) (508) Density 0.075 lb/ft ⁄ (38) (406) ⁄ (708) (813) 1000 2000 3000 4000 5000 6000 7000 (813) (813) /hr X 1000 Damper size = 28 x 28 (711 x 711) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 314 (142) *Motor cover is optional.
Page 39
BSQ 240 - Belt Drive ⁄ (835) (559) Density 0.075 lb/ft ⁄ (38) (483) ⁄ (886) (991) cfm X 1000 (991) (864) /hr X 1000 Damper size = 35 x 35 (889 x 889) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 415 (188) *Motor cover is optional.
Page 40
BSQ 240HP - Belt Drive ⁄ (835) (559) 1200 Density 0.075 lb/ft 1000 ⁄ (38) (483) ⁄ (886) (991) cfm X 1000 (991) (864) /hr X 1000 Damper size = 35 x 35 (889 x 889) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 415 (188) *Motor cover is optional.
Page 41
BSQ 300 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1064) (1168) cfm X 1000 (1168) (965) /hr X 1000 Damper size = 42 x 42 (1067 x 1067) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 537 (244) *Motor cover is optional.
Page 42
BSQ 300HP - Belt Drive (864) (559) 1100 1000 Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1064) (1168) (1168) cfm X 1000 (965) /hr X 1000 Damper size = 42 x 42 (1067 x 1067) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 537 (244) *Motor cover is optional.
Page 43
BSQ 360 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1216) (1321) (1321) cfm X 1000 (1067) /hr X 1000 Damper size = 48 x 48 (1219 x 1219) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 686 (311) *Motor cover is optional.
Page 44
BSQ 360HP - Belt Drive (864) (559) 1100 1000 Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1216) (1321) (1321) cfm X 1000 (1067) /hr X 1000 Damper size = 48 x 48 (1219 x 1219) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 686 (311) *Motor cover is optional.
Page 45
BSQ 420 - Belt Drive (864) (559) Density 0.075 lb/ft ⁄ (38) (457) ⁄ (1368) (1473) (1473) cfm X 1000 (1270) /hr X 1000 Damper size = 54 x 54 (1372 x 1372) Dimensions shown in inches (millimeters) and weight is shown in pounds (kilograms). Unit weight** = 789 (358) *Motor cover is optional.
Fan shall be centrifugal direct drive type Fan shall be model SQ as manufactured by in upblast, downblast, or inline configuration with Greenheck Fan Corporation of Schofield, controllable EC Vari-Green motor. Wisconsin, USA. Remote Dial...
Page 47
Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Fan shall bear a permanently affixed manufacturer’s nameplate containing the model number and individual serial number for future identification. Fan shall be model BSQ as manufactured by Greenheck Fan Corporation of Schofield, Wisconsin, USA.
Need help?
Do you have a question about the SQ and is the answer not in the manual?