3.2 liters/4.2 liters hot water dispenser with dual-pump system (6 pages)
Summary of Contents for SPT SP-3618
Page 1
FEATURES Instruction Manual Automatic Dispensing Reboil Function Automatic Dispensing Hot Water Pot with One-Touch Dispense Multi-temperature Function 5 Temperature Settings Cleaning Function Multi-temp Image selections 208°F For tea, coffee, instant noodle. 194°F Keep warm around 194°F. Citric acid 176°F Keep warm around 176°F. 140°F For infant formula.
Important Safeguards Warning. To prevent possible electric shock and injury: Do not fill READ ALL INSTRUCTIONS BEFORE USE Open lid with caution, do water above not use force. When using an electrical the FULL appliance, basic precautions indicator. Do not cover the should always be followed, SYMBOLS steam outlet.
Notice Parts Identification Do not use other than Be cautious of hot steam the supplied power when opening the lid. cord. Plug in dedicated Do not add water during socket. the boiling process. Unplug from power Never turn the unit upside source when not in use.
Operating Instructions Adding Water 1. Open lid and add water. 2. Close lid firmly. Opening and closing the lid Removing and attaching the lid To open: press down with thumb To remove: press down on the Release 3. Connect power. and pull latch upwards.
Re-Boil Temperature Setting 5 temperature settings: 208°F, • Cool Setting: unit will boil water To reboil water, press the REBOIL button. Unit will beep and 194 °F, 176 °F, 140 °F, and Cool. then stop heating. Pressing the Re- Boil indicator will lit. boil button will reboil water.
Adding Water Dry Boil • Add water when water level falls within the red section on the Water Level Indicator. • Unit will automatically begin to boil after adding water. If not, press the Reboil button. If there is no water or if water level is low, Dry boil indicator Press Reboil button...
The rubber gasket on the lid will wear over time and will need to be period of time, clean unit and replaced periodically. Contact Sunpentown (www.spt-usa.com / 909- Power Cord allow unit to dry completely. 468-5288) to purchase replacement gaskets or for instruction to send •...
Troubleshooting PROBLEM CAUSE REMEDY No power Loose power Check connection at connection the unit and socket. Your Guarantee Cannot switch to Water level is too Add water. If this product is found to be faulty as a result of faulty materials or boil / reboil low.
Need help?
Do you have a question about the SP-3618 and is the answer not in the manual?
Questions and answers