MNP Command Summary (continued)
Command
\ N 2
\ N 3
\N4
\ N 5
\ N 6
\ N 7
\ O
\ Q 0
\ Q 1
\ Q 2
\ Q 3
\Q4
\ Q 5
\ Q 6
\ S
\T0
\T n
\ U
\V0
\V1
\X0
\X1
\ Y
\ Z
&Q5
Description
Set reliable mode
Set auto-reliable mode
Set V.42(LAP-M) mode
Set V.42 auto-reliable mode
Set V.42/MNP reliable mode
Set V.42/MNP auto-reliable mode
Force a reliable link independent of whether or not the modem
originated or answered the call
Disable flow control
Enable XON/XOFF flow control
Enable RTS/CTS flow control
Enable XON/XOFF software flow control
Enable unidirectional hardware flow control, keeping CTS off
until connection is established
Unidirectional, keep CTS of until connection established
Kept CTS off until connection for bidirectional hardware flow
control established
Display on-line modem status
Inactivity timer: Disables timer
Sets timer to number (n) up to 90 minutes
Accept a reliable link request independent of whether or not
the modem originated or answered the call
Disable extended MNP and V.42 result codes
Enable extended MNP and V.42 result codes
Disable XON/XOFF pass through, but still process
Enable XON/XOFF pass through and process
Establish on MNP reliable link while already connected in direct
m o d e
Switch to direct mode
Select error correction mode
To make on MNP5 connection:
&Q5 plus S36 = 7 (MNP)
S46 = 138 (MNP5)
S48 = 128 (Fallback, no V.42)
To make on MNP4 connection:
&Q5 plus S36 = 7 (MNP)
S46 = 133 (No compression)
S48 = 128 (Fallback, no V.42)