Expand serial command functional specifications
Hide thumbs Also See for PLC-XM100/L - 5000 Lumens:
Table of Contents

Advertisement

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
SANYO Electric Co., Ltd
Projector Division
PLC-XM100
PLC-XM150
PLC-XM100L
PLC-XM150L
Ver.1.0
DS Company

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-XM100/L - 5000 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XM100 PLC-XM150 PLC-XM100L PLC-XM150L Ver.1.0 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications Contents 1. Overview .........................9 2. Serial Interface Specification..................9 2.1 Transfer Specification ....................9 2.2 Connection ........................9 3. Notes for communication....................10 4. Notation Convention....................10 5. Functional Execution Command Table..............11 5.1 Image Command Table....................11 5.2 PC Adjust Control Command Table.................11 5.3 Input Control Command Table .................11 5.4 Screen Control Command Table ................12 5.5 Lamp Command Table ....................12...
  • Page 3 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.9 CF_OFFSET- Command ..................20 8.4.10 CF_NZRED Command ..................20 8.4.11 CF_PROGV Command ..................21 8.4.12 CF_IMAGE Command ..................21 8.4.13 CF_IMAGEADJ Command................22 8.5 PC Adjust Control Command ...................23 8.5.1 CF_FSYNC Command..................23 8.5.2 CF_TDOTS Command..................23 8.5.3 CF_CLPPHASE Command .................23 8.5.4 CF_H-POS Command ..................24 8.5.5 CF_V-POS Command..................24 8.5.6 CF_DDOTS Command ..................24...
  • Page 4 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.15 CF_HPOS Command..................36 8.8 Lamp Command......................37 8.8.1 CF_LAMPMODE Command................37 8.8.2 CF_LAMPLIFECONTRL_ Command ..............37 8.9 Sound Command .......................38 8.9.1 CF_VOLUME Command ..................38 8.9.2 CF_MUTE Command...................38 8.9.3 CF_BLTINSP Command..................38 8.10 Setting Command ....................39 8.10.1 CF_LANG Command..................39 8.10.2 CF_MENUPOSITION Command...............39 8.10.3 CF_INPUTBUTTON Command.................39 8.10.4 CF_DISP Command ..................40...
  • Page 5 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.11.1 CF_KEYEMU Command..................48 8.11.2 CF_MENU Command ..................48 8.11.3 CF_POWER Command ..................49 8.11.4 CF_FREEZE Command..................49 8.11.5 CF_VMUTE Command ..................49 Status Read Command ....................50 9. 9.1 Format .........................50 9.2 Transfer Example .......................50 9.3 Operation Condition ....................50 9.4 Image Status Read Command ..................50 9.4.1 CR_BRIGHT Command ..................50 9.4.2 CR_CONT Command ..................50...
  • Page 6 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7 Input Read Command....................59 9.7.1 CR_INPUT Command..................59 9.7.2 CR_SOURCE Command..................59 9.7.3 CR_SRCINP1 Command..................59 9.7.4 CR_SRCINP2 Command..................59 9.7.5 CR_SRCINP3 Command..................60 9.7.6 CR_SRCINP4 Command..................60 9.7.7 CR_SYSTEM Command ..................61 9.7.8 CR_SYSLIST Command ..................62 9.7.9 CR_MODELIST Command..................62 9.7.10 CR_HMSLOT Command ...................63 9.7.11 CR_NMSLOT1 Command .................63 9.7.12 CR_NMSLOT2 Command .................63 9.7.13 CR_NMSLOT3 Command .................63...
  • Page 7 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.10.2 CR_MUTE Command ..................69 9.10.3 CR_BLTINSP Command ...................69 9.11 Setting Status Read Command ................70 9.11.1 CR_LANG Command ..................70 9.11.2 CR_INPUTBUTTON Command.................70 9.11.3 CR_DISP Command ..................70 9.11.4 CR_BACKGND Command ................70 9.11.5 CR_LOGO Command ..................71 9.11.6 CR_LOGOLOCK Command................71 9.11.7 CR_FILREMAIN Command................71 9.11.8 CR_FILH Command...................71 9.11.9 CR_FILTIMER Command ..................71...
  • Page 8 PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12.4 CR_FREEZE Command ..................77 9.12.5 CR_TEMPFAIL Command ................78 9.12.6 CR_TEMP Command ..................79 9.12.7 CR_SHUTCOND Command................79 9.12.8 CR_SERIALNO Command................79 8/79...
  • Page 9: Overview

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 1. Overview ・ This Functional Specification defines communication with PJ-Net organizer for PLC-XM100 / XM100L / XM150 / XM150L. ・ Supporting Firmware Ver. 1.x of the projector. ・ Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
  • Page 10: Notes For Communication

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 3. Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
  • Page 11: Functional Execution Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_SHARP_%1 [CR] Set value of Sharpness CF_GAMMA_%1 [CR]...
  • Page 12: Screen Control Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 5.4 Screen Control Command Table Execute command Item CF_SCREEN_%1 [CR] Select Screen size CF_DZCENT _%1 [CR] Cancel Digital Zoom mode CF_KEYSTONE _%1 [CR] Set Keystone correction CF_KYSTNMODE _%1 [CR] Set Keystone store mode CF_CORNER-UL_%1[CR] Correct top-left corner CF_CORNER-UR_%1[CR] Correct top-right corner...
  • Page 13: Other Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CF_PJPINCODE_%1[CR] Enter PJ PIN code to cancel PJ lock CF_SHUTRCPROT_%1[CR] Set valid / invalid of RC use on Shutter control function Set valid / invalid use of key on the top panel on Shutter CF_SHUTKEYPROT_%1[CR] control function CF_SHUTH_%1[CR]...
  • Page 14: Status Read Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_SHARP [CR] Get value of Sharpness...
  • Page 15: Screen Status Read Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CR_IDSLOT1[CR] Get ID information of Input1 CR_IDSLOT2[CR] Get ID information of Input2 CR_IDSLOT3[CR] Get ID information of Input3 CR_IDSLOT4[CR] Get ID information of Input4 6.5 Screen Status Read Command Table Status Read command Item CR_SCREEN [CR] Get selected screen size CR_VSCALE[CR]...
  • Page 16: Other Status Read Command Table

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications CR_P-MANETIME [CR] Get setting time for Power Management CR_STANDBYMODE [CR] Get selected mode of Standby function CR_ON-STA [CR] Get ON Start setting status CR_POINTER[CR] Get setting status of Pointer CR_PTIMEMODE[CR] Get setting mode of P-timer CR_PTIMER[CR] Get status of P-timer CR_PTIME[CR]...
  • Page 17: Functional Execution Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
  • Page 18: Image Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 19: Cf_Sharp Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-031”--------------- Directly specify setting value of Sharpness “UP”--------------------- Increment setting value of Sharpness by 1 “DN”--------------------- Decrement setting value of Sharpness by 1 Set user controlled value of Sharpness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 20: Cf_Coltemp Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ------------------------------ Xlow “001”------------------------------- Low “002”------------------------------- Mid “003”------------------------------- High Set Color Temperature The value set by this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
  • Page 21: Cf_Progv Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.11 CF_PROGV Command Command “CF_PROGV_%1” [CR] “ON” ----------------- Set Progressive scan to On. “FILM” --------------- Set Progressive scan to Film. “OFF” ---------------- Set Progressive scan to OFF. “UP” ------------------ Switch setting forward direction (OFF→ON→FILM→OFF) “DN”...
  • Page 22: Cf_Imageadj Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.4.13 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4 “STR5”---- Store current adjusted value to Image 5 “STR6”---- Store current adjusted value to Image 6...
  • Page 23: Pc Adjust Control Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
  • Page 24: Cf_H-Pos Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
  • Page 25: Cf_Dline Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
  • Page 26: Cf_Orgmode Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.9 CF_ORGMODE Command Command “CF_ORGMODE_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Specify VGA1 “VGA2” ------------------------ Specify VGA2 “XGA1” ------------------------ Specify XGA1 “WXGA3” --------------------- Specify WXGA3 “1080I60” --------------------- Specify 1080i60 “1080I50” --------------------- Specify 1080i50 “1035I”...
  • Page 27: Cf_Pcmodefree Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.5.11 CF_PCMODEFREE Command Command “CF_PCMODEFREE_%1” [CR] “1” --------------------------- Set Mode1 to Free status “2” --------------------------- Set Mode2 to Free status “3” --------------------------- Set Mode3 to Free status “4” --------------------------- Set Mode4 to Free status “5”...
  • Page 28: Input Control Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1”------------------------- Select Input 1 (not switching Source) “2”------------------------- Select Input 2 (not switching Source) “3”------------------------- Select Input 3 (not switching Source) “4”------------------------- Select Input 4 (Network viewer) “UP”---------------------- Increment Input No.
  • Page 29: Cf_Input 1 Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT 1 Command Command “CF_INPUT1_%1” [CR] “DIGITAL” -------------------------- Select PC Digital Input “ANALOG” ------------------------- Select PC Analog Input “SCART” --------------------------- Select SCART Input “HDCP” ---------------------------- Select DVI HDCP Input Select Input 1 as well as Source specified in %1 (Available only in the normal Details Power ON status) Acceptable...
  • Page 30: Cf_System Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.6.7 CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” --------------------------- Select VGA1 “VGA2” --------------------------- Select VGA2 “XGA1” --------------------------- Select XGA1 “WXGA3” --------------------- Select WXGA3 “1080I” ------------------------ Select 1080i “1035I” ------------------------ Select 1035i Input is “720P” ------------------------- Select 720p PC Analog “575P”...
  • Page 31: Screen Control Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “WIDE” --------------------------- Select Wide mode “TRUE” -------------------------- Select True mode “FULL” --------------------------- Select Full screen mode “CUSTOM” ---------------------- Select Custom mode Input is Computer “DZOOM_UP”...
  • Page 32: Cf_Keystone Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 33: Cf_Corner-Ur Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
  • Page 34: Cf_Cornertestpat Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.9 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Corner correction. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 35: Cf_Vscale Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.12 CF_VSCALE Command Command “CF_VSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 : “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐31” ---------------------‐31 “‐32” ---------------------‐32 “UP” --------------------- Increment setting value of Vscale by 1 “DN”...
  • Page 36: Cf_Hscale Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.7.14 CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 : “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐31” ---------------------‐31 “‐32” ---------------------‐32 “UP” --------------------- Increment setting value of Hscale by 1 “DN”...
  • Page 37: Lamp Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “NORMAL” ------------------------ Set Lamp status to Normal mode “ECO1” ------------------------------- Set Lamp status to Eco1 mode “ECO2” ------------------------------- Set Lamp status to Eco2 mode “AUTO” ----------------------------- Set Lamp status to Auto mode Select Lamp mode (Available only in the normal Power ON status) Details The value set by this command is stored in EEPROM and the setting remains...
  • Page 38: Sound Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000-063” --------------------------- Directly specify value of Volume. “UP” --------------------------------- Increment setting value of Volume by 1 “DN” --------------------------------- Decrement setting value of Volume by 1 Control level of Volume (Available only in the normal Power ON status) Set Volume Up/Down the same way as RC and also directly specify value of Volume.
  • Page 39: Setting Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select ENGLISH “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 40: Cf_Disp Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.4 CF_DISP Command Command “CF_DISP_%1” [CR] “ON” ----------------------------- Set Display to On “CNTDWNOFF” --------------- Set Display to Count down Off “OFF” --------------------------- Set Display to Off “UP” --------------- Switch forward (On → Count down Off → Off → On → ---) “DN”...
  • Page 41: Cf_Logo Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.6 CF_LOGO Command Command “CF_LOGO_%1_%2” [CR] “0000 – 9999” ------------- Directly set Logo PIN code “OFF” ---------------------------Cancel Logo display “DFLT” ------------------------- Select Logo of Factory Default “USER” ------------------------ Select User “UP” ---------------------------- Select functions to choose forward (OFF →...
  • Page 42: Cf_Filscrl Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.10 CF_FILSCRL Command Command “CF_FILSCRL_%1” [CR] “RST” ---------------------- Reset Filter scroll counter Details Reset Filter scroll counter Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.10.11 CF_FANSPEED Command Command “CF_FANSPEED_%1” [CR] “MAX” ------------------------------ Select maximum fan speed “NOR”...
  • Page 43: Cf_Rsens Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.14 CF_RSENS Command Command “CF_RSENS_%1” [CR] “ALL” ----------------------------------- Select top, front and back receiver of projector “FRONTTOP” ------------------------ Select front and top receivers of projector “BACKTOP” -------------------------- Select only back and top receivers of projector “FRONTBACK”...
  • Page 44: Cf_Standbymode Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.17 CF_STANDBYMODE Command Command “CF_STANDBYMODE_%1” [CR] “ECO” ----------------------- Less standby electricity “NORMAL” -------------- Normal standby electricity Switch Standby Mode setting. Details (Available in normal Power ON status only). Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.10.18 CF_ON-STA Command Command “CF_ON-STA_%1”...
  • Page 45: Cf_Ptimer Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.21 CF_PTIMER Command Command “CF_PTIMER_%1” [CR] “START” -------------------------- Start P-timer “STOP” ---------------------------- Stop P-timer “RESTART” ---------------------- Resume P-timer “RST” ------------------------------ Reset P-timer “EXIT” ----------------------------- Exit P-timer function Select the status of P-timer. Details (Available only in the normal Power ON status) Acceptable “000”...
  • Page 46: Cf_Pjpincode Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.24 CF_PJPINCODE Command Command “CF_PJPINCODE_%1” [CR] “0000 – 9999” ------------- Directly specify PJ PIN code Enter PIN code to cancel PIN code lock (Available only in the normal Power ON status) PIN code can not be changed. (Only PIN code lock is canceled.) *When PIN code Lock is enabled: PIN code is matched ------------------------- Command is valid (Acceptable) PIN code is mismatched -------------------- Command is invalid (Error code “102”)
  • Page 47: Cf_Shuth Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.10.27 CF_SHUTH Command Command “CF_SHUTH_%1” [CR] “005”-“180”----------Specify setting time directly “UP” ------------------ Add 1 minute “DN” ------------------Decrease 1 minute Set time of operating shutter management function. (Valid only when in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 48: Other Commands

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.11 Other Commands 8.11.1 CF_KEYEMU Command Command “CF_KEYEMU_%1” [CR] “RIGHT” ---------------- Move Pointer rightward in On-Screen Display Menu “LEFT” ------------------ Move Pointer leftward in On-Screen Display Menu “UP” ---------------------- Move Pointer to upward On-Screen Display Menu “DN”...
  • Page 49: Cf_Power Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
  • Page 50: Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
  • Page 51: Cr_Tint Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.4 CR_TINT Command Command “CR_TINT” [CR] Details Get user controlled value of Tint Acceptable “000_%1” [CR] “000 – 063” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input). “?”...
  • Page 52: Cr_Wbal-B Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.9 CR_WBAL-B Command Command “CR_WBAL-B” [CR] Details Get user controlled Blue value of White Balance Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.10 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1”...
  • Page 53: Cr_Nzred Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.4.14 CR_NZRED Command Command “CR_NZRED” [CR] Details Get Noise Reduction setting status Acceptable “000_%1” [CR] “OFF” ----------------------------- Cancel Noise Reduction Response “ON” --------------------------------Set Noise Reduction Unacceptable “Error Code” [CR] 9.4.15 CR_PROGV Command Command “CR_PROGV” [CR] Details Get Progressive scan setting status Acceptable...
  • Page 54: Pc Adjust Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input) “?”...
  • Page 55: Cr_V-Pos Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.5 CR_V-POS Command Command “CR_V-POS” [CR] Details Get value of Vertical Position Acceptable “000_%1” [CR] “0000 – nnnn” (nnnn = Total Line – Display area V) Response “Error Code” [CR] ------ When command is not available in the Unacceptable given condition (such as being selected input “?”...
  • Page 56: Cr_Orgmode Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-50 is not selected, get the current signal. Acceptable “000_%1”...
  • Page 57: Cr_Pcstore Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.5.9 CR_PCSTORE Command Command “CR_PCSTORE” [CR] Get Free or Stored status of MODE1 - 5 in PC Adjust. Details Data consists of 10 bytes and each byte represents MODE1-10. (F:Free, S:Stored) Acceptable “000_%1” [CR] “FFFFFFFFFF”...
  • Page 58: Video Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case for PC-Analog/PC-Digital/AV HDCP signals) Acceptable “000_%1”...
  • Page 59: Input Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected INPUT No. Acceptable “000_%1” [CR] Response “1 – 4” Unacceptable “Error Code” [CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected source Acceptable “000_%1”...
  • Page 60: Cr_Srcinp3 Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.5 CR_SRCINP3 Command Command “CR_SRCINP3” [CR] Details Get Source of INPUT3 Acceptable “000_%1” [CR] “VIDEO” ----------------------- in Video mode Response “S-VIDEO” -------------------- in S-video mode “YPBPR” ---------------------- in Y,Pb/Cb,Pr/Cr mode Unacceptable “Error Code” [CR] 9.7.6 CR_SRCINP4 Command Command “CR_SRCINP4”...
  • Page 61: Cr_System Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.7 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] “VGA1” ------------------------- indicates VGA1 is selected “VGA2” ------------------------- indicates VGA2 is selected “XGA1” ------------------------- indicates XGA1 is selected “WXGA3” ---------------------- indicates WXGA3 is selected “1080I”...
  • Page 62: Cr_Syslist Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog; “XGA1”...
  • Page 63: Cr_Hmslot Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command Command “CR_NMSLOT1”...
  • Page 64: Cr_Idslot1 Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “30” --------------- On-board (DVI-D and D-Sub) Response Available source: DIGITAL, ANALOG, SCART, HDCP Unacceptable “Error Code”...
  • Page 65: Screen Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “WIDE” --------------------------- Wide mode “FULL” --------------------------- Full screen mode Response “TRUE”...
  • Page 66: Cr_ Kystnmode Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7 CR_CORNERTESTPAT Command Command “CR_CORNERTESTPAT”...
  • Page 67: Lamp Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
  • Page 68: Cr_Projh Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
  • Page 69: Sound Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME” [CR] Get volume value by user control Details * When input signal is Network, error code “101” is returned. Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code”...
  • Page 70: Setting Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
  • Page 71: Cr_Logo Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.5 CR_LOGO Command Command “CR_LOGO” [CR] Details Get setting status of Logo Acceptable “000_%1” [CR] “DFLT” ----------------------------- Default Logo is enabled Response “USER” --------------------------- User is enabled “OFF” ------------------------------ Logo is disabled Unacceptable “Error Code” [CR] 9.11.6 CR_LOGOLOCK Command Command “CR_LOGOLOCK”...
  • Page 72: Cr_Filcond Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.10 CR_FILCOND Command Command “CR_FILCOND” [CR] Details Get status of filter clog Acceptable “000_%1” [CR] “CLOG” = Filter is clogged Response “WARN” = Filter is nearly clogged “CLEAN” = Filter is not clogged Unacceptable “Error Code”...
  • Page 73: Cr_Rsens Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.15 CR_RSENS Command Command “CR_RSENS” [CR] Details Get selected location of infrared remote receiver of remote control Acceptable “000_%1” [CR] “ALL” -------- Select top, front and back receiver of projector “FRONTTOP” ----- Select front and top receiver of projector “BACKTOP”...
  • Page 74: Cr_On-Sta Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.20 CR_ON-STA Command Command “CR_ON-STA” [CR] Details Get setting status of Power ON Start Acceptable “000_%1” [CR] “ON” -------------------------- Power ON Start is ON Response “OFF” ------------------------ Power ON Start is OFF Unacceptable “Error Code” [CR] 9.11.21 CR_POINTER Command Command “CR_POINTER”...
  • Page 75: Cr_Keydis Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.25 CR_KEYDIS Command Command “CR_KEYDIS” [CR] Details Get status of RC/KEY (valid or invalid) Acceptable “000_%1” [CR] “NONE” -------------------------- RC and KEY, both are valid Response “RC” ------------------------------- RC is invalid “KEY” ----------------------------- KEY is invalid Unacceptable “Error Code”...
  • Page 76: Cr_Shutkeyprot Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.11.30 CR_SHUTKEYPROT Command Command “CR_SHUTKEYPROT” [CR] Details Get status if Shutter can be controlled by key on the top panel Acceptable “000_%1” [CR] “ON” ------------- Shutter is not controllable by key on the top panel Response “OFF”...
  • Page 77: Other Status Read Commands

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 78: Cr_Tempfail Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
  • Page 79: Cr_Temp Command

    PLC-XM100/XM100L/XM150/XM150L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.

Table of Contents