Wiring Connections; Connection Procedure; Recommended Fusing And Wiring Data; Pressure Switch Wiring - Craftsman 390.2522 Owner's Manual

Professional "hydroglass '' convertible deep well jet pump
Hide thumbs Also See for 390.2522:
Table of Contents

Advertisement

ELECTRICAL
Wiring
Connections
[
*_.WARNING
] Fire hazard.
Incorrect
voltage
can cause
a fire or seriously
damage
the motor
and voids the war-
ranty. The supply voltage
must be within
_+10% of the
motor
nameplate
voltage.
NOTICE:
Dual-voltage
motors
are factory
wired
for
230 volts. If necessary,
reconnect
the motor
for 115
volts, as shown.
Do not alter the wiring
in single volt-
age motors.
Install, ground,
wire, and maintain
your pump
in com-
pliance
with the National
Electrical
Code (NEC) or the
Canadian
Electrical
Code
(CEC),
as applicable,
and
with all local codes
and ordinances
that apply. Consult
your local building
inspector
for code information.
Motor wires connect here.
-Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. it does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
31870398
Figure
I0 - Pressure switch wiring
Connection
Procedure
1.
2.
.
.
Connect
the ground
vdre first as shown
in Figure 10.
The ground
wire must be a soEd copper
wire at least
as large as the power
supply wires.
There must be a solid metal connection
between
the
pressure
switch
and the motor for motor
grounding
protection.
If the pressure
switch
is not connected
to the motor, connect
the green ground
screw in the
switch
to the green ground
screw under
the motor
end cover. Use a solid copper
vdre at least as large
as the power
supply wires.
Connect
the ground
wire to a grounded
lead in a ser-
vice panel, to a metal undergrotmd
water
pipe, to a
metal well casing at least ten feet (3/7I) long, or to a
ground
electrode
provided
by the power
company
or the hydro authority.
Connect
the power
supply
wires
to the pressure
switch
as shown
in Figure
10.
Pump
Model
390.2519
390.2522
RECOMMENDED
FUSING
AND WIRING
DATA
Motor
Horse-
power
3/4
Volts
115
23O
115
230
Max.
Load
Amperes
12.4
6,2
14,2
7.6
Branch*
Delayed
Fuse
Rating
Amps
20.0
15.0
20.0
15.0
Distance in Feet From
Motor to Meter
0
51
101
201
to
to
to
to
50
100
200
300
Win _ Size
12
12
10
8
14
14
14
14
12
12
8
6
14
14
14
14
* Time delayed fuses are recommended
instead of fuses in any motor circuit.
10