Download Print this page

Craftsman 919.167462 Owner's Manual

Permanently lubricated single stage side stack air compressor

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
i CRHFTSMRN'i
Permanently
Lubricated
Single Stage
Side Stack
AIR COMPRESSOR
Model No.
919.167462
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D30050
Rev0
8/26/03

Advertisement

loading

Summary of Contents for Craftsman 919.167462

  • Page 1 Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D30050 Rev0 8/26/03...
  • Page 2 HOW TO ORDER REPAIR PARTS ...... Back Cover ltl__1 ;| ;[_I_ hi" FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
  • Page 3: Glossary

    _ ".,1 =[e]I =1 [_,__1 II[o] _ I[e] -"_',__ t,tl Model No. 919.167462 Max. Developed HP Running HP Bore 2.375" Stroke 1.35" Voltage-Single Phase 120V Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons Approximate Cut-in Pressure Approximate...
  • Page 4 I I_ I_o] ;111P'.'q +IInl[,.'9'.,_ _1 _ &'i __JL_[,._)III,_]LI_+']IIT[_o _+]L_,[,._ Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment, ,l;1"l'J "-In WARNING: Risk of explosion or fire What Could Happen...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury, What Could Haopen How To Prevent It Failure to properly drain condensed Drain tank daily or after each use.
  • Page 6 :f:1"4_;ll WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric shock.
  • Page 7 WARNING: Risk of Burns How To Prevent It What Could Happen Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns. hot for several minutes after operation.
  • Page 8 WARNING: Risk of Unsafe Operation What Could Happen How To Prevent It Review and understand all instructions Unsafe operation of your air compressor and warnings in this manual could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Duty Cycle

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10 _'-_._ _h_ I _] _'d Unpacking Remove unit from carton and discard all packaging. HOW TO SET UP YOUR must be installed and grounded in accordance with all local codes and UNIT ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration...
  • Page 11 Extension Cords Voltage and Circuit Protection Refer to the specification chart for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit requirements. cords will cause voltage to drop resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 12 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Compressor Pump Outlet Universal Gauge...
  • Page 13 Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the Pressure cooling system is working when air is Release...
  • Page 14 Run the compressor for 15 Risk of Bursting. Too minutes. Make sure the drain much air pressure causes a hazardous risk of bursting. valve is open and there is Check the manufacturer's maximum minimal air pressure build-up in pressure rating for air tools and tank.
  • Page 15 Customer Responsibilities Before Daily _aoh e_er F_quently Yearly each Check Safety Valve Drain Tank Air Filter • (1) Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions To Check Safety Valve Risk of Unsafe Operation.
  • Page 16 After the water has been drained, Air Compressor Pump Intake close the drain valve (clockwise). and Exhaust Valves The air compressor can now be Once a year have a Trained Service stored. Technician check the air compressor NOTE: If drain valve is plugged, pump intake and exhaust valves.
  • Page 17 ALL MAINTENANCE AND REPAIR Using an adjustable wrench loosen pressure relief tube nut at OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED air tank and pressure switch. SERVICE TECHNICIAN. Carefully move pressure relief tube away from check valve. IIR_'_II Risk of Unsafe Unscrew the check valve (turn Operation.
  • Page 18 Before you store the air compressor, Risk of Bursting. make sure you do the following: Water will condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and pe_orm scheduled of air tank rupture.
  • Page 19 h| -'Toll : J_oXo_ V_II Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 PROBLEM CORRECTION CAUSE If there is an excessive amount It is normal for "some" Pressure reading pressure drop to occur. of pressure drop when the on the regulated accessory is used, adjust the pressure gauge regulator as instructed in the (if equipped) Operation section.
  • Page 21 PROBLEM CORRECTION CAUSE Motor will not Let motor cool off and Motor overload protection overload switch will run. switch has tripped. automatically reset. Motor will start automatically Tank pressure exceeds 3ressure switch "cut-in" when tank pressure drops 3ressure. below "cut-in" pressure of pressure switch.
  • Page 22 Air Compressor Model Number 919.167462 ,o++++ 17+1 Tot ue 17+2 30_¢_ O0 Torque 17+8 25+31in.++bs. TorqtJe 50-60 in.-_s. © Torque $0-20 in.-I_s. D30050 22+ ENG...
  • Page 23: Assembly

    Drain Valve AC-0430 SSP-7811 Assembly, Nut Sleeve 1/4" AC-0631 Check Valve AC-0261 Grip D30074 Label, Performance LA-3061 Label, Craftsman Professional 5" LA-3108 Label, Hot Surface LA-3062 Label, Craftsman Professional 9" D24006 Label, Compressor Rating * Order individual parts, see pump breakdown •...
  • Page 24 Air Compressor Model Number 919.167462 84 Torque 7-10 ff.-Ibs. 79-4 _79-3 _-<_ 79-2 74,_,=k in.-Ibs. D30050 24+ ENG...
  • Page 25 Air Compressor Model Number 919.167462 PART NUMBER DESCRIPTION • Z-D26713 Motor SSF-615 Screw, 1/4-20 x 1.25" AC-0140 Eccentric Bearing Assembly AC-0108 SSF-586 Screw 1/4-20 x .75", SEMS +x 78 Cylinder Sleeve Connecting Rod Assembly +x 79-2 DAC-308 Formed Compression Ring 79-3 ACG-29 Connecting...
  • Page 26 GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opei6n, 1o reparar& o reempiazar& sin eosto alguno.
  • Page 27 Modelo N ° 919.167462 Max. HP desarrollado Potencia de trabajo 1,8 HP Di&metro interior 2,875" (47,6 mm) Oarrera 1,35" (31,8 mm) 120V Voltaje-corriente manofAsica Circuito mfnimo requerido Tipo de fusibleAccibn retardada Capacidad de aire en el tanque 4 Galones (22,7 litros) Presibn de eorte de entrada 120 psig Presibn de corte de salida...
  • Page 28 GUARDE ESTAS INSTRUCCIONES La operaciSn o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y dafios a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. ',]=lm [_ ;{_ ADVERTENCIA: Riesgo de Explosi6n o Incendio qud puede occurrir cbmo...
  • Page 29 d=ln[_,{q F 3%q ADVERTENCIA: Riesgo de Explosibn T_ue de aire: Ins siguientes condiciones podrfan, causar el debilitamiento del tanque, determinar su explosi6n violenta, daSos a la propiedad o serias lesiones. qud puede occurrir c6mo prevenido Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu_s de...
  • Page 30 •,,l ::1 n nl [_1;{q ADVERTENCIA: Riesgo de choque eldctrico qud puede occurrir cbmo prevenirlo Su compresor de aire est& accionado pot Jam_s opere el compresor a la intemperie electr_cidad. Como cualquier otto disposffivo cuando est& Iloviendo o en condiciones el_ctrico imputsado e_'tricamente,...
  • Page 31 ",,1 =ltq [_ t,{, ADVERTENCIA: Riesgo de Quemaduras qu_ puede occurrir crime prevenitlo Jam_is toque partes de metal expuestas en el Tocar el metal expuesto tal come el cabezal compresor durante o inmediatamente despu_s del compresor o los tubes de sa_ida del de la operaci6n, el compresor permanecerd escape, puede ocasionarie...
  • Page 32 ADVERTENCIA: Riesgo de Serias Lesiones o Da_os a la Propiedad Transportar el Compresor (Fuego, inhalaci6n, da_o a la superficie de vehiculos) qud puede occutrit cbmo prevenirlo resultar en serias lesiones o la muerte debido protectora cuando Io transporte, a fin de al riesgo de incendio o inhalaci6n.
  • Page 33 Presibn minima de torte: Cuando el Familiarlcese con los siguientes terminos, motor esta apagado, la presion del tanque antes de operar la unidad: de aire baja a medida que usted continQa CFM: (Cubic feet per minute) Pies cQbicos usando su accesorio. Cuando la presion pot minuto.
  • Page 34 Desempaque Extraiga la unidad de su caja y descarte todas les partes de embalaje. C6MO PREPARAR LA UNIDAD AsegQrese de que el tomacorriente que sera utilizado tenga la misma configaraci6n que el enchufe de Ubicacibn del compresor de aire conexion a tierra. NO UTILtCE UN Ubique al compresor de aire en una zona ADAPTADOR.
  • Page 35 Cables de extensibn eldctrica Proteccibn del voltaje y del circuito No se recomienda la utilizacion de cables Acerca del voltaic y la minima cantidad de extension el6ctrica. El uso de cables circuitos requeridos, refi_rase al cuadro de especifieaeiones. de extension el6ctrica originar& una caida de tensi6n, Io que determinar&...
  • Page 36 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones Conserve este manual para referencias futuras.
  • Page 37 Bomba de compresi6n del aire: Cemprime el aire dentro de{ tanque. El aire de trebajo no se encuentra disponible hasta que el compresor haya elcanzado a Ilenar el tanque hasta un nivel de presion per encima del requerido para la selida del aire.
  • Page 38 Luego de 15 minutos, cierre la v&lvu_ade Cbmo porter en marcha: drenaje (sentido horario). El aire recibido Mueva la pa_ancaOn/Auto/Off a _a ira I_enando hasta el punto de "corte" de posici6n "AUTO" y deje que se presi6n, y el motor se detendr& incremente la presi6n del tanque.
  • Page 39 _w_r:_ _bi _ _1hV_ll _ _I I[a Responsabilidades del cliente Antes [_edamente AnuaJmente :recuentemente cada otuego de cada uso Verifique la valvula de seguridad Drenaje del tanque Filtro de aire Valvulas de entrada y escape de la bomba del compresor de aire 1- M&S frecuente en condiciones polvorientas...
  • Page 40 Un filtro de aire sucio no permitir& a la Riesgo de Explosibn. Dentto bomba compresora, operar a su del tanque se ptoducitd condensacibn capacidad m&xima. Antes de usar la de agua. Si no drena, el agua Io bomba compresora, verifique el filtro de cortoerd y debilitard causando un aire para asegurarse que este limpio yen...
  • Page 41 TODO TIPO DE MANTENIMIENTO Utilizando una Ilave regulable, afloje OPERACIONES DE REPARACION NO el tube aliviador de presi6n del MENCIONADOS, DEBEP_N SER tanque de aire y el interruptor de EFECTUADOS POR PERSONAL TECNICO presion. Retire cuidadosamente ESPECIALIZADO. tuberfa de alivio de presi6n de la valvula de retencion.
  • Page 42 Drene el agua del tanque de aire Antes de guarder su compresor de aire, abriendo la valvula de drenaje asegQrese de haeer Io siguiente: ubicada en el rondo del tanque. Revise la secci6n "Mantenimiento" de las p&ginas precedentes y ejecute Riesgo de Explosibn.
  • Page 43 [_l_.,_ Im] _ I m] p ';l_] Z [T_"-]lli[o,,[o] I m] " _ I _ :To]:] nil = 1 i_Y;%,."] Riesgo de Operacibn Insegura: La unidad arranca automdticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles.
  • Page 44 PROBLEMA CORRECCION CAUSA Si habiese una caida excesiva de ESnormal que ocurra algQn La lectura de la descenso en la presi6n. presi6n durante el uso del presi6n sobre an accesorio, ajaste el regulador man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 45 CAUSA CORRECCION PROBLEMA El motor no El interruptor de protecci6n Deje enfriar el motor y el funciona. obrecarga del motor se ha interruptor de sobrecerga se abierto. reajustar& autom&ticamente. El motor arrancar& autom&ticamente La presi6n del tanque excede la presi6n de "corte maximo" caando la presi6n del tanque caiga del interruptor de presi6n.
  • Page 46 D30050 46- S P...
  • Page 47: Installation

    Agreements Reparaciones Congratulations on making a smart Felicitaciones per hacer una cempra purchase. Your new Craftsman '_ product is inteligente. Su nueva unidad Craftsman ® est& designed and manufactured for years of diseSada y fabricada para aSos de operaci6n dependable operation.
  • Page 48 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances...