Sanyo PLC-XF1000 - 12000 Lumens Manual
Sanyo PLC-XF1000 - 12000 Lumens Manual

Sanyo PLC-XF1000 - 12000 Lumens Manual

Rs232 expand serial command
Hide thumbs Also See for PLC-XF1000 - 12000 Lumens:
Table of Contents

Advertisement

Quick Links

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XF1000
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-XF1000 - 12000 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XF1000 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-XF1000 Expand Serial Command Functional Specifications CONTENTS 1. Overview .........................8 2. Serial Interface Specification..................8 2.1 Transfer Specification ....................8 2.2 Connection ........................8 3. Notes for communication....................9 4. Notation.........................10 5. Functional Execution Command Table..............11 5.1 Image Command Table....................11 5.2 PC Control Command Table ..................11 5.3 Input Control Command Table .................12 5.4 Screen Command Table ....................12 5.5 Lamp Command Table ....................12...
  • Page 3 PLC-XF1000 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command ...................20 8.4.9 CF_WBAL- Command..................21 8.4.10 CF_OFFSET- Command ...................21 8.4.11 CF_SHARP Command ..................21 8.4.12 CF_GAMMA Command..................22 8.4.13 CF_NZRED Command ..................22 8.4.14 CF_PROGV Command..................22 8.4.15 CF_IMAGE Command ..................23 8.4.16 CF_IMAGEADJ Command................23 8.4.17 CF_ADVCOL Command..................24 8.5 PC Control Command ....................25 8.5.1 CF_FSYNC Command..................25 8.5.2 CF_TDOTS Command..................25...
  • Page 4 PLC-XF1000 Expand Serial Command Functional Specifications 8.8.2 CF_LAMPMODE Command................35 8.8.3 CF_AUTOLAMPCONTRL Command ..............35 8.9 Setting Command ......................36 8.9.1 CF_LANG Command...................36 8.9.2 CF_DISP Command ....................36 8.9.3 CF_BACKGND Command ..................36 8.9.4 CF_LOGO Command ..................37 8.9.5 CF_FANSPEED Command .................37 8.9.6 CF_RCODE Command..................37 8.9.7 CF_RSENS Command ..................38 8.9.8 CF_P-MANE Command ..................38 8.9.9 CF_P-MANETIME Command................38 8.9.10 CF_ON-STA Command ..................38...
  • Page 5 PLC-XF1000 Expand Serial Command Functional Specifications 9.4.5 CR_APCTRL Command..................44 9.4.6 CR_COLTEMP Command ...................45 9.4.7 CR_WBAL-R Command..................45 9.4.8 CR_WBAL-G Command ..................45 9.4.9 CR_WBAL-B Command..................45 9.4.10 CR_OFFSET-R Command ................45 9.4.11 CR_OFFSET-G Command ................45 9.4.12 CR_OFFSET-B Command ................46 9.4.13 CR_SHARP Command..................46 9.4.14 CR_GAMMA Command ..................46 9.4.15 CR_NZRED Command ..................46 9.4.16 CR_PROGV Command ..................46 9.4.17 CR_IMAGE Command ..................47...
  • Page 6 PLC-XF1000 Expand Serial Command Functional Specifications 9.7.12 CR_NMSLOT4 Command .................55 9.7.13 CR_IDSLOT1 Command ...................56 9.7.14 CR_IDSLOT2 Command ...................56 9.7.15 CR_IDSLOT3 Command ...................56 9.7.16 CR_IDSLOT4 Command ...................56 9.8 Screen Status Read Commands ................57 9.8.1 CR_SCREEN Command ..................57 9.8.2 CR_KYSTNMODE Command ................57 9.8.3 CR_CEIL Command ....................57 9.8.4 CR_REAR Command ..................57 9.8.5 CR_VSCALE Command..................57...
  • Page 7 PLC-XF1000 Expand Serial Command Functional Specifications 9.10.17 CR_PJLOCKNOW Command.................64 9.10.18 CR_PJLOCMENU Command................64 9.10.19 CR_FILH Command ..................64 9.10.20 CR_FILCOND Command ................65 9.10.21 CR_FILREPL Command .................65 9.10.22 CR_FILTIMER Command................65 9.10.23 CR_FILREMAIN Command................65 9.10.24 CR_TESTPAT Command ................66 9.11 Other Status Read Commands ................67 9.11.1 CR_STATUS Command..................67 9.11.2 CR_SIGNAL Command ..................67 9.11.3 CR_VMUTE Command..................67...
  • Page 8: Overview

    PLC-XF1000 Expand Serial Command Functional Specifications 1. Overview ・ This Functional Specification defines communication with Network board for PLC-XF1000. ・ Commands are designed to communicate with Network board, but most commands are also available to remote-control a projector through RS-232C from a computer. Therefore, commands are defined as Expand Serial Commands.
  • Page 9: Notes For Communication

    PLC-XF1000 Expand Serial Command Functional Specifications 3. Notes for communication ・ Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). ・ When a projector receives carriage return (0x0D), it starts decoding. ・...
  • Page 10: Notation

    PLC-XF1000 Expand Serial Command Functional Specifications 4. Notation ・ Data from a controller to a projector is represented as COMMAND, and data from a projector to a controller in response to the incoming command is represented as RESPONSE. ・ [CR]: Carriage Return Code The command ends with carriage return code.
  • Page 11: Functional Execution Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Item CF_CONT_%1[CR] Set value of Contrast CF_BRIGHT_%1[CR] Set value of Brightness CF_COLOR_%1[CR] Set value of Color CF_TINT_%1[CR] Set value of Tint CF_COLMNSAV_%1[CR] Set area to store current values of Color Management CF_COLMNLD_%1[CR] Set area to load values of Color Management CF_APCTRL_%1[CR]...
  • Page 12: Input Control Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 5.3 Input Control Command Table Execute command Item CF_INPUT_%1[CR] Select Input CF_SOURCE_%1[CR] Select Source of selected Input CF_INPUT1_%1[CR] Select Input1 and also set input source to %1 CF_INPUT2_%1[CR] Select Input2 and also set input source to %1 CF_INPUT3_%1[CR] Select Input3 and also set input source to %1 CF_INPUT4_%1[CR]...
  • Page 13: Setting Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 5.6 Setting Command Table Execute command Item CF_LANG_%1[CR] Select language for OSD CF_DISP_%1[CR] Set ON/OFF of On Screen Display CF_BACKGND_%1[CR] Select screen for no signal CF_LOGO_%1[CR] Set ON/OFF of Logo CF_FANSPEED_%1[CR] Select Fan Speed CF_RCODE_%1[CR] Select Remote Control Code Select location of infrared remote receiver of...
  • Page 14: Status Read Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_CONT [CR] Get value of Contrast CR_BRIGHT [CR] Get value of Brightness CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_APCTRL Get setting status of Auto Picture Control...
  • Page 15: Input Status Read Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 6.4 Input Status Read Command Table Status read command Item CR_INPUT [CR] Get selected Input CR_SOURCE [CR] Get selected Source CR_SYSTEM [CR] Get selected System in Video Input mode CR_SRCINP1 [CR] Get selected source for Input 1 CR_SRCINP2 [CR] Get selected source for Input 2 CR_SRCINP3 [CR]...
  • Page 16: Setting Status Read Command Table

    PLC-XF1000 Expand Serial Command Functional Specifications 6.7 Setting Status Read Command Table Status read command Item CR_LANG [CR] Get selected language CR_DISP [CR] Get setting status of Display CR_BACKGND [CR] Get setting status of Screen for no signal CR_LOGO [CR] Get setting status of Logo CR_LOGOLOCK [CR] Get setting status of Logo Lock...
  • Page 17: Error Code Table

    PLC-XF1000 Expand Serial Command Functional Specifications 7. Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception (This is “Not” error) Specified function is not available in the selected mode Specified value is out of range (Not reflected) Command mismatched to Hardware (the command...
  • Page 18: Functional Execution Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1) PC issues a command in the format below: Pattern1: “CF_Command” [CR] Pattern2: “CF_Command_” %1 [CR] CF_: Header Command: String %1: Parameter (String) _: Space (To separate Command and Parameter) 2) The projector decodes the received command and when it gets ready to receive another command, it returns the response.
  • Page 19: Image Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ CONT Command Command “CF_CONT_%1” [CR] “000-063”--------------- Directly specify setting value of Contrast “UP”--------------------- Increment setting value of Contrast by 1 “DN”--------------------- Decrement setting value of Contrast by 1 Set user controlled value of Contrast. (Available only in the normal Power ON status) Details The value set by this command is not stored in the projector.
  • Page 20: Cf_Colmnsav Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4.5 CF_COLMNSAV Command Command “CF_COLMNSAV_%1” [CR] “000 – 009” ---------------- Specify the area to store Store current setting status of Color Management to the area specified in %1. Details (Available only in the normal Power ON status) Acceptable “000”...
  • Page 21: Cf_Wbal- Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4.9 CF_WBAL- Command Command “CF_WBAL-%1_%2” [CR] “R” ------------- RED “G” ------------ GREEN “B” ------------- BLUE “000-063”------ Directly specify value of Color selected in %1 of White Balance. “UP”------ Increment setting value of Color specified in %1 of White Balance by 1 “DN”----- Decrement setting value of Color specified in %1 of White Balance by 1 Set value of Color specified in %1 of White Balance (Available only in the normal Power ON status)
  • Page 22: Cf_Gamma Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4.12 CF_GAMMA Command Command “CF_GAMMA_%1” [CR] “000-015” ---------------- Directly specify setting value of Gamma “UP”---------------------- Increment setting value of Gamma by 1 “DN”---------------------- Decrement setting value of Gamma by 1 Set user controlled value of Gamma. (Available only in the normal Power ON status) Details The value set by this command is not stored in the projector’s memory.
  • Page 23: Cf_Image Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4.15 CF_IMAGE Command Command “CF_IMAGE__%1” [CR] “STAND” ----------- Standard (Image adjustment value is set to factory default) “REAL” ------------- Real (Fixed value to display graphic image with natural tone) “CINEMA” --------- Cinema (Fixed value to focus on tone reproduction for movie) “CUSTOM1”...
  • Page 24: Cf_Advcol Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.4.17 CF_ADVCOL Command Command “CF_ADVCOL_%1” [CR] “AUTO” -------------- Set Advanced color to Auto “OFF” ----------------- Set Advanced color OFF. “ UP” ------------------ Switch setting forward direction (OFF→Auto→OFF→Auto) “ DN” ------------------ Switch setting backward direction (OFF→Auto→OFF→Auto) *”UP”...
  • Page 25: Pc Control Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.5 PC Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) The value set by this command is not stored in the projector’s memory.
  • Page 26: Cf_V-Pos Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.5.4 CF_V-POS Command Command “CF_V-POS_%1” [CR] “0000-nnnn” ------------ Directly specify setting value of Vertical Position “nnnn” indicates maximum value, which is current (Total Line – Display Area V) value “UP” --------------------- Increment setting value of Vertical Position by 1 “DN”...
  • Page 27: Cf_Dline Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
  • Page 28: Cf_Pcstore Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.5.10 CF_PCSTORE Command Command “CF_PCSTORE_%1” [CR] “MODE1” --------------------------- Store current PC Adjust status to Mode1 “MODE2” --------------------------- Store current PC Adjust status to Mode2 “MODE3” --------------------------- Store current PC Adjust status to Mode3 “MODE4” --------------------------- Store current PC Adjust status to Mode4 “MODE5”...
  • Page 29: Input Control Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1” ---------------------------------- Select Input 1 “2” ---------------------------------- Select Input 2 “3” ---------------------------------- Select Input 3 "4” ---------------------------------- Select Input 4 “UP”-------------------------------- Increment Input No. by 1 “DN”-------------------------------- Decrement Input No.
  • Page 30: Cf_System Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.6.4 CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” --------------------------- Select VGA1 “VGA2” --------------------------- Select VGA2 “XGA1” --------------------------- Select XGA1 “WXGA3” --------------------- Select WXGA3 “1080I” ------------------------ Select 1080i “1035I” ------------------------ Select 1035i Input is “720P” ------------------------- Select 720p PC Analog “575P”...
  • Page 31: Screen Control Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “TRUE” -------------------------- Select True mode “WIDE” --------------------------- Select Wide mode “FULL” --------------------------- Select Full mode “CUSTOM” ---------------------- Select Custom mode “DZOOM□UP”...
  • Page 32: Cf_Keystone Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 33: Cf_Rear Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.7.6 CF_REAR Command Command “CF_REAR_%1” [CR] “ON” --------------------------- Set Rear to ON “OFF” ------------------------- Set Rear to OFF Set/Cancel Rear. (Valid only when in the normal Power ON status.) When Rear is set to ON, image is left/right reversed. Details The status set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status.
  • Page 34: Cf_Hscale Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.7.9 CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 : “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “‐01” ---------------------‐1 “‐02” ---------------------‐2 : “‐31” ---------------------‐31 “‐32” ---------------------‐32 “UP” --------------------- Increment setting value of Hscale by 1 “DN”...
  • Page 35: Lamp Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1” [CR] “RSTn” (n=1-2) --------------------------- Reset lamp 1-2 running time Reset running time of the lamp specified in “n”. Details (Valid only when it is in the normal Power ON status.) Acceptable “000”...
  • Page 36: Setting Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9 Setting Command 8.9.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select ENGLISH “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 37: Cf_Logo Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9.4 CF_LOGO Command Command “CF_LOGO_%1_%2” [CR] “0000 – 9999” ------------- Directly set Logo PIN code “OFF” ---------------------------Cancel Logo display “DFLT” ------------------------- Select Logo of Factory Default “USER” ------------------------ Select User “UP” ---------------------------- Select functions to choose forward (OFF →...
  • Page 38: Cf_Rsens Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9.7 CF_RSENS Command Command “CF_RSENS_%1” [CR] “BOTH” -------------------------------- Select both front and back receiver of projector “FRONT” ---------------------------- Select only front receiver of projector “BACK” ------------------------------------ Select only back receiver of projector “UP” --------- Switch forward (BOTH → FRONT → BACK → BOTH) “DN”...
  • Page 39: Cf_Pjpincode Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9.11 CF_PJPINCODE Command Command “CF_PJPINCODE_%1” [CR] “0000 – 9999” ------------- Directly specify PJ PIN code Enter PIN code to cancel PIN code lock (Available only in the normal Power ON status) PIN code can not be changed. (Only PIN code lock is canceled.) *When PIN code Lock is enabled: PIN code is matched ------------------------- Command is valid (Acceptable) PIN code is mismatched -------------------- Command is invalid (Error code “102”)
  • Page 40: Cf_Filscrl Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9.15 CF_FILSCRL Command Command “CF_FILSCRL_%1” [CR] “RST” ---------------------- Reset Filter scroll counter Details Reset Filter scroll counter Acceptable Acceptable Response Unacceptable Unacceptable 8.9.16 CF_TESTPAT Command Command “CF_TESTPAT_%1” [CR] “COLOR” ---------------------- Display Color bar “GRAD1” ---------------------- Display 16step(white→black) “GRAD2”...
  • Page 41: Cf_Shutrcprot Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.9.19 CF_SHUTRCPROT Command Command “CF_SHUTRCPROT_%1” [CR] “ON” ------------------ Disable RC key from controlling Shutter (Protection On) “OFF” ----------------- Enable RC key to control Shutter (Protection Off) Set valid / invalid of RC use on Shutter control function Details (Valid only when in the normal Power ON status) Acceptable...
  • Page 42: Hd Data Wireless Command

    PLC-XF1000 Expand Serial Command Functional Specifications 8.11 HD data wireless Command 8.11.1 CF_HDWLMODE Command Command “CF_HDWLMODE_%1” [CR] “SINGLE”------------------ 1-1 mode “BLOADCAST” ---------- 1-N mode Set communication mode with a radio transmitter. Details (Valid only when HD-wireless input is selected) Acceptable “000”...
  • Page 43: Status Read Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues a command in the format below: “CR_Command” [CR] Command: String When the projector receives the applicable command, it returns the required information as a data string. “000_”...
  • Page 44: Image Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.4 Image Status Read Commands 9.4.1 CR_CONT Command Command “CR_CONT” [CR] Details Get user controlled value of Contrast Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “?” [CR] 9.4.2 CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get user controlled value of Brightness Acceptable...
  • Page 45: Cr_Coltemp Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.4.6 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1” [CR] “000” ~“003” Response “BLANK” ---- OSD Menu is blank (Neither of Xlow / Low / Mid / High) Unacceptable “?”...
  • Page 46: Cr_Offset-B Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.4.12 CR_OFFSET-B Command Command “CR_OFFSET-B” [CR] Details Get user controlled Blue value of Offset Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “?” [CR] 9.4.13 CR_SHARP Command Command “CR_SHARP” [CR] Details Get user controlled value of Sharpness Acceptable “000_%1”...
  • Page 47: Cr_Image Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.4.17 CR_IMAGE Command Command “CR_IMAGE” [CR] Get image setting status. Details The Required data “CUSTOM1” – “CUSTOM10” corresponds to “Image1” – “Image10” displayed when selecting Image on OSD Menu. Acceptable “000_%1” [CR] “STAND” ---------------------------------- Standard “REAL”...
  • Page 48: Pc Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.5 PC Status Read Commands 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] Response “0000” – “0031” “Error Code” [CR] -------------- When command is invalid in the Unacceptable given condition (such as being selected input) “?”...
  • Page 49: Cr_Clamp Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.5.5 CR_CLAMP Command Command “CR_CLAMP” [CR] Details Get value of Clamp Acceptable “000_%1” [CR] “0000” – “ 4095” Response “Error Code” [CR] -------------- When command is invalid in the Unacceptable given condition (such as being selected input) “?”...
  • Page 50: Cr_Setpcadj Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.5.8 CR_SETPCADJ Command Command “CR_SETPCADJ” [CR] Details Get PC signal for current system Acceptable “000_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Indicates VGA1 is selected “VGA2” ------------------------ Indicates VGA2 is selected “XGA1”...
  • Page 51: Cr_Orgmode Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.5.9 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-60 is not selected, get the current signal. Acceptable “000_%1”...
  • Page 52: Video Status Read Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get currently selected signal. Details Value only when Input is video. (Invalid when Input is computer) Acceptable “000_%1” [CR] “1080I60”--------------- 1080i 60Hz “1080I50” -------------- 1080i 50Hz “1035I”...
  • Page 53: Cr_System Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.7.3 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] “VGA1” ------------------------- indicates VGA1 is selected “VGA2” ------------------------- indicates VGA2 is selected “XGA1” ------------------------- indicates XGA1 is selected “WXGA3” ---------------------- indicates WXGA3 is selected “1080I”...
  • Page 54: Cr_Srcinp1 Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.7.4 CR_SRCINP1 Command Command “CR_SRCINP1” [CR] Details Get Source of Input1 Acceptable “000_%1” [CR] “DIGITAL” ---------------------- in Computer mode “ANALOG”“ -------------------- in Computer mode “VIDEO” ------------------------- in Video mode “S-VIDEO” ---------------------- in Video mode “YPBPR”...
  • Page 55: Cr_Nmslot1 Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.7.9 CR_NMSLOT1 Command Command “CR_NMSLOT1” [CR] Details Get the board name inserted to Slot1 Acceptable “000_%1” [CR] “HDCP-DVI2” -------------------- Input1/ New HDCP&DVI board “5BNC-VIDEO”------------------- Input2/ New Video board “VGA” ----------------------------- VGA D-Sub board “NETWORK” -------------------- NETWORK board “5BNC”...
  • Page 56: Cr_Idslot1 Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.7.13 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information on Slot 1.This command is used to recognize the inserted Details board and specify the valid Input source. Acceptable “000_%1” [CR] “01” --------------- D-sub board Valid Input Source: ANALOG “03”...
  • Page 57: Screen Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.8 Screen Status Read Commands 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get currently selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “WIDE” --------------------------- Wide mode “FULL” --------------------------- Full mode Response “TRUE”...
  • Page 58: Cr_Hscale Command

    PLC-XF1000 Expand Serial Command Functional Specifications Command “CR_VPOS” [CR] Details Get setting status of V Position Acceptable “000_%1” [CR] Response “-15”-”015” Unacceptable “Error Code” [CR] 9.8.7 CR_HSCALE Command Command “CR_HSCALE” [CR] Details Get setting status of H scale Acceptable “000_%1” [CR] Response “-32”-”035”...
  • Page 59: Lamp Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get the information of Lamp Replacement time Acceptable “000_%1” [CR] “2**” 2 ---------------- indicates 2 lamps are used in this model. * ---------------- indicates the status of each lamp in lamp number order.
  • Page 60: Cr_Inflamp Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.9.5 CR_INFLAMP Command Command “CR_INFLAMP” [CR] Details Get Lamp mode switching status Acceptable “000_%1” [CR] “NML” --------- in Normal status (lamp switching operation is not Response active.) “CNG” ---------- during lamp switching operation Unacceptable “?”...
  • Page 61: Setting Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10 Setting Status Read Commands 9.10.1 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK”...
  • Page 62: Cr_Rsens Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10.6 CR_RSENS Command Command “CR_RSENS” [CR] Details Get selected location of infrared remote receiver of remote control Acceptable “000_%1” [CR] “BOTH” --------Select both front and back receiver of projector Response “FRONT” ----- Select only front receiver of projector “BACK”...
  • Page 63: Cr_P-Manetime Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10.10 CR_P-MANETIME Command Command “CR_P-MAETIME” [CR] Details Get setting time for starting Power Management function Acceptable “000_%1” [CR] Response “001 – 030” ----------------------- 1 to 30 minutes Unacceptable “?” [CR] 9.10.11 CR_FANSPEED Command Command “CR_FANSPEED”...
  • Page 64: Cr_Shuth Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10.15 CR_SHUTH Command Command “CR_SHUTH” [CR] Details Get time setting to start the shutter management Acceptable “000_%1” [CR] “005” -------------------- 5 minutes “006” -------------------- 6 minutes Response “179” -------------------- 179 minutes “180” -------------------- 180 minutes Unacceptable “?”...
  • Page 65: Cr_Filcond Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10.20 CR_FILCOND Command Command “CR_FILCOND” [CR] Details Get status of filter clog Acceptable “000_%1” [CR] “CLOG” = Filter is clogged Response “WARN” = Filter is nearly clogged “CLEAN” = Filter is not clogged Unacceptable “Error Code”...
  • Page 66: Cr_Testpat Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.10.24 CR_TESTPAT Command Command “CR_TESTPAT” [CR] Details Get setting status of Test pattern Acceptable “000_%1” [CR] “COLOR” ---------------------- Color bar is displayed “GRAD1” ---------------------- 16step(white→black) is displayed “GRAD2” ---------------------- 16step(white←black) is displayed “GRAD3” ---------------------- 16step(white↓black) is displayed Response “GRAD4”...
  • Page 67: Other Status Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.11 Other Status Read Commands 9.11.1 CR_STATUS Command Command “CR_STATUS” [CR] Get operating status of Projector Details Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 68: Cr_P-Timer Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.11.5 CR_P-TIMER Command Command “CR_P-TIMER” [CR] Details Get Presentation Timer operating status Acceptable “000_%1” [CR] “ON” ---------------------------- Presentation Timer is ongoing. Response ”STOP” ------------------------ Presentation Timer is paused. “OFF” -------------------------- Presentation Timer is not active. Unacceptable “?”...
  • Page 69: Cr_Tempfail Command

    PLC-XF1000 Expand Serial Command Functional Specifications 9.11.7 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside the projector when the abnormal status occurs. Details It is possible to get the temperatures for more than one sensor all at once if it is applicable.
  • Page 70: Hd-Wireless Read Commands

    PLC-XF1000 Expand Serial Command Functional Specifications 9.12 HD-wireless Read Commands 9.12.1 CR_ HDWLMODE Command Command “CR_HDWLMODE”[CR] Get communication mode with a radio transmitter. Details (Valid only when HD-wireless input is selected) Acceptable “000_%1” [CR] “SINGLE”------------- 1-1 mode is set Response “BROADCAST”----- 1-N mode is set Unacceptable “Error Code”...
  • Page 71: Command With Address Specification

    PLC-XF1000 Expand Serial Command Functional Specifications 10. Command with Address Specification 10.1. Overview - Commands with address are used to remote control more than one projector through RS-232C by a computer. - The command with address is defined as a single command per line that starts with “A” and ends with carriage return (0x0D).
  • Page 72: When The Command Pipelining Is Needed

    PLC-XF1000 Expand Serial Command Functional Specifications 10.2.2. When the command pipelining is needed When it needs command pipelining, the operation is the same as the remote control as below: Sending-side system issues commands every 100ms When receiving an applicable command, the function is executed repeatedly for 120ms.

This manual is also suitable for:

Plc-xf1000