  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WTC500L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-WTC500L Expand Serial Command Functional Specifications Contents Overview .........................8 1ÿ Serial Interface Specification ..................8 2ÿ 2.1 Transfer Specification ....................8 2.2 Connection ........................8 Notes for communication ....................9 3ÿ Notation Convention ......................9 4ÿ Functional Execution Command Table..............10 5ÿ 5.1 Image Command Table ..................... 10 5.2 PC Adjust Control Command Table ................
  • Page 3 PLC-WTC500L Expand Serial Command Functional Specifications 8.4.9 CF_NZRED Command ..................19 8.4.10 CF_PROGV Command ..................19 8.4.11 CF_IMAGE Command ..................19 8.4.12 CF_IMAGEADJ Command ................20 8.5 PC Adjust Control Command .................. 21 8.5.1 CF_FSYNC Command..................21 8.5.2 CF_TDOTS Command..................21 8.5.3 CF_CLPPHASE Command ................
  • Page 4 PLC-WTC500L Expand Serial Command Functional Specifications 8.8.5 CF_LAMPCHGSTA Command................33 8.8.6 CF_LAMPINTERVAL Command ................ 33 8.9 Sound Command ...................... 34 8.9.1 CF_VOLUME Command ..................34 8.9.2 CF_MUTE Command..................34 8.10 Setting Command ....................35 8.10.1 CF_LANG Command..................35 8.10.2 CF_LOGO Command ..................35 8.10.3 CF_PIP Command ....................
  • Page 5 PLC-WTC500L Expand Serial Command Functional Specifications 8.11.5 CF_VMUTE Command ..................45 Status Read Command ................... 46 9ÿ 9.1 Format ........................46 9.2 Transfer Example ...................... 46 9.3 Operation Condition ....................46 9.4 Image Status Read Command ................. 46 9.4.1 CR_BRIGHT Command ..................46 9.4.2 CR_CONT Command ..................
  • Page 6 PLC-WTC500L Expand Serial Command Functional Specifications 9.7.7 CR_SYSTEM Command ..................55 9.7.8 CR_SYSLIST Command ..................56 9.7.9 CR_MODELIST Command ................. 56 9.7.10 CR_HMSLOT Command .................. 57 9.7.11 CR_NMSLOT1 Command ................57 9.7.12 CR_NMSLOT2 Command ................57 9.7.13 CR_NMSLOT3 Command ................57 9.7.14 CR_NMSLOT4 Command ................
  • Page 7 PLC-WTC500L Expand Serial Command Functional Specifications 9.11.3 CR_LOGOLOCK Command................65 9.11.4 CR_PIP Command .................... 65 9.11.5 CR_PIPSIZE Command ..................66 9.11.6 CR_PIPPOSITION Command ................66 9.11.7 CR_BACKGND Command ................66 9.11.8 CR_POINTER Command ................. 66 9.11.9 CR_RCODE Command ..................67 9.11.10 CR_RCSENSOR Command ................
  • Page 8: Overview

    PLC-WTC500L Expand Serial Command Functional Specifications 1ÿ Overview 0û This Functional Specification defines communication with PJ-Net organizer for PLC-WTC500L. 0û Supporting Firmware Ver. 1.x of the projector. 0û Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
  • Page 9: Notes For Communication

    PLC-WTC500L Expand Serial Command Functional Specifications 3ÿ Notes for communication 0û Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). 0û There are two types of commands; Functional Execution Commands and Status Read Command. - Example of Functional Execution Command: “CF_BRIGHT_032”...
  • Page 10: Functional Execution Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications 5ÿ Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_SHARP_%1 [CR] Set value of Sharpness CF_GAMMA_%1 [CR]...
  • Page 11: Screen Control Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications 5.4 Screen Control Command Table Execute command Item CF_SCREEN_%1 [CR] Select Screen size CF_DZCENT _%1 [CR] Cancel Digital Zoom mode CF_CEIL_%1 [CR] Set ON/OFF of Ceiling CF_REAR_%1 [CR] Set ON/OFF of Rear CF_KEYSTONE _%1 [CR] Set Keystone correction CF_KYSTNMODE _%1 [CR] Set Keystone store mode...
  • Page 12: Other Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications CF_FILH_%1[CR] Reset Filter used time Set time to display Filter cleaning / replacement warning CF_FILTIMER_%1[CR] on screen CF_FILSCRL_%1[CR] Reset Filter scroll counter CF_FDEFAULT_%1 [CR] Reset to Factory Default settings 5.8 Other Command Table Execute command Item CF_KEYEMU_%1 [CR] The same operation as RC/Control Key...
  • Page 13: Status Read Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications 6ÿ Status Read Command Table 6.1 Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_SHARP [CR] Get value of Sharpness...
  • Page 14: Screen Status Read Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications CR_IDSLOT3[CR] Get ID information of Input3 CR_IDSLOT4[CR] Get ID information of Input4 6.5 Screen Status Read Command Table Status Read command Item CR_SCREEN [CR] Get selected screen size CR_CEIL [CR] Get setting status of Ceiling CR_REAR [CR] Get setting status of Rear CR_KYSTNMODE[CR]...
  • Page 15: Other Status Read Command Table

    PLC-WTC500L Expand Serial Command Functional Specifications CR_SHUTKEYPROT[CR] Get Key controller disability state of the shutter CR_SHUTH[CR] Get time setting to begin the shutter management CR_HDMISETUP [CR] Get setting status of Image of “HDMI setup” CR_HDMISOUND [CR] Get setting status of Sound of “HDMI setup” CR_SECURITY [CR] Get setting status of Security CR_PJLOCKNOW [CR]...
  • Page 16: Functional Execution Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8ÿ Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
  • Page 17: Image Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”-------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 18: Cf_Sharp Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-015”--------------- Directly specify setting value of Sharpness “UP”--------------------- Increment setting value of Sharpness by 1 “DN”--------------------- Decrement setting value of Sharpness by 1 Set user controlled value of Sharpness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 19: Cf_Coltemp Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ------------------------------ Xlow “001”------------------------------- Low “002”------------------------------- Mid “003”------------------------------- High Set Color Temperature (Available only in the normal Power ON status) The value set by this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
  • Page 20: Cf_Imageadj Command

    PLC-WTC500L Expand Serial Command Functional Specifications “CUSTOM4” ------------- Image4 ÿ the value adjusted and stored by userÿ Select Image Mode (Available only in the normal Power ON status) Parameter “CUSTOM1” to “CUSTOM4” corresponds to “Image1” to “Image4” Details displayed in projector OSD menu on selecting Image. The value set by this command is stored in EEPROM so that the setting can remain effective even after the power is turned to ALL OFF status.
  • Page 21: Pc Adjust Control Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
  • Page 22: Cf_V-Pos Command

    PLC-WTC500L Expand Serial Command Functional Specifications Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. Acceptable “000” [CR] Response Unacceptable “101” [CR] --- When input is Video signal / No signal 8.5.5 CF_V-POS Command Command “CF_V-POS_%1”...
  • Page 23: Cf_Setpcadj Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.5.8 CF_SETPCADJ Command Command “CF_SETPCADJ_%1” [CR] None “EXT11-60” 1. Apply value set in PC Adjust Menu to projected image. Specifying setting value directly in the following PC Adjust related commands immediately reflects them on projected image, while issuing this command after these commands also triggers the reflection.
  • Page 24: Cf_Pcstore Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.5.10 CF_PCSTORE Command Command “CF_PCSTORE_%1” [CR] “1” --------------------------- Store current value of PC Adjust to Mode1 “2” --------------------------- Store current value of PC Adjust to Mode2 “3” --------------------------- Store current value of PC Adjust to Mode3 “4”...
  • Page 25: Input Control Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1”------------------------- Select Input 1 (not switching Source) “2”------------------------- Select Input 2 (not switching Source) “3”------------------------- Select Input 3 (not switching Source) “4”------------------------- Select Input 4 (Network viewer) “UP”---------------------- Increment Input No.
  • Page 26: Cf_Input 1 Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT 1 Command Command “CF_INPUT1_%1” [CR] “HDMI” ----------------------------- Select HDMI Input “ANALOG” ------------------------ Select PC Analog Input “SCART” --------------------------- Select SCART Input Select Input 1 as well as Source specified in %1 (Available only in the normal Details Power ON status) Acceptable...
  • Page 27: Cf_System Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.6.7 CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” --------------------------- Select VGA1 “VGA2” --------------------------- Select VGA2 “XGA1” --------------------------- Select XGA1 “WXGA3” --------------------- Select WXGA3 Input is “1080I” ------------------------ Select 1080i PC Analog “1035I” ------------------------ Select 1035i “720p”...
  • Page 28: Screen Control Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “TRUE” -------------------------- Select True mode “FULL” --------------------------- Select Full mode “CUSTOM” ---------------------- Select Custom mode Input is Computer “DZOOM_UP” ----------------- Scale up with Digital zoom “DZOOM_DN”...
  • Page 29: Cf_Rear Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.7.4 CF_REAR Command Command “CF_REAR_%1” [CR] “ON” --------------------------- Set Rear to ON. “OFF” ------------------------- Set Rear to OFF. Set/Cancel Rear mode (Available only in the normal Power ON status) When Rear is ON, projected image is left/right reversed. Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 30: Cf_Vscale Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.7.7 CF_VSCALE Command Command “CF_VSCALE_%1” [CR] “032” ---------------------- +32 “031” ---------------------- +31 ÿ “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 ÿ “ 31” --------------------- 31 “...
  • Page 31: Cf_Hscale Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.7.9 CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “032” ---------------------- +32 “031” ---------------------- +31 ÿ “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 ÿ “ 31” --------------------- 31 “...
  • Page 32: Lamp Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “AUTO1” ------------- Set lamp status to Auto1 mode “AUTO2” ------------- Set lamp status to Auto2 mode “HIGH” --------------- Set lamp status to High mode “NORMAL” ---------- Set Lamp status to Normal mode “ECO1”...
  • Page 33: Cf_Lampchgsta Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.8.5 CF_LAMPCHGSTA Command Command “CF_LAMPCHGSTA_%1” [CR] “00”-“24” ---------------------- Set Start time of Timer Set Start time of Timer for Lamp1/2 of Lamp mode. Details (Valid only when in the normal Power ON status.) *When Lamp mode is not set to Lamp1/2, error code “101” is returned. Acceptable “000”...
  • Page 34: Sound Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1”[CR] “000-063” --------------------------- Directly select Volume setting value “UP” --------------------------------- Current Volume setting value +1 “DN” --------------------------------- Current Volume setting value -1 Control level of volume. (Available only in the normal Power ON status) Set Volume Up/Down the same way as remote control and also directly select Details Volume setting value.
  • Page 35: Setting Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select ENGLISH “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 36: Cf_Pipsize Command

    PLC-WTC500L Expand Serial Command Functional Specifications The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status. Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.10.4 CF_PIPSIZE Command Command “CF_PIPSIZE_%1”...
  • Page 37: Cf_Filctl Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.7 CF_FILCTL Command Command “CF_FILCTL_%1” [CR] “ROLL” ---------------------- Execute operation of scroll of filter Details Execute operation of scroll of filter Acceptable Acceptable Response Unacceptable Unacceptable 8.10.8 CF_POINTER Command Command “CF_POINTER_%1_%2”[CR] “SPOTLIGHT” --------------- Select Spotlight “ARROW”...
  • Page 38: Cf_Rcsensor Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.10 CF_RCSENSOR Command Command “CF_RCSENSOR_%1” [CR] “ALL” -------------------------- Select all receiver of projector “FRONTTOP” ---------------- Select both front and top receiver of projector “BACKTOP” ------------------ Select both back and top receiver of projector “FRONTBACK” -------------- Select both front and back receiver of projector “FRONT”...
  • Page 39: Cf_P-Mane Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.13 CF_P-MANE Command Command “CF_P-MANE_%1” [CR] “OFF” ---------------------------------- Set Power Management to Off “READY” ----------------------------- Set Power Management to Ready “SHUTDOWN” --------------------- Set Power Management to Shut Down mode “UP” ----------------------- Switch forward (Off→Ready→Shut down→Off) “DN”...
  • Page 40: Cf_Slant Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.17 CF_SLANT Command Command “CF_HIGHLAND_%1”[CR] “OFF” ----------------- Install a projector at L3 degree angle in front projection, or at L4 degree angle in ceiling projection “L1” ------------------- Slant a projector at L1 degree angle “L2”...
  • Page 41: Cf_Hdmi Setup Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.21 CF_HDMI SETUP Command Command “CF_HDMISETUP_%1”[CR] “NORMAL”----------------------Select Normal “ENHANCED” -----------------Select Enhanced Set status of HDMI setup - Image. (Valid only when in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 42: Cf_Keydis Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.24 CF_KEYDIS Command Command “CF_KEYDIS_%1” [CR] “NONE” ---------------------- RC & Projector keys are valid (All are valid) “RCALL” --------------------- All RC keys are invalid “RCPART” ------------------- Specific RC keys are invalid “KEYALL” -------------------- All projector keys are invalid “KEYPART”...
  • Page 43: Cf_Filscrl Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.10.28 CF_FILSCRL Command Command “CF_FILSCRL_%1” [CR] “RST” ---------------------- Reset Filter scroll counter Details Reset Filter scroll counter Acceptable Acceptable Response Unacceptable “Error Code” [CR] 8.10.29 CF_ FDEFAULT Command Command “CF_FDEFAULT_%1” [CR] “RST” Reset to Factory Default setting Details (Available only in the normal Power ON status) Acceptable...
  • Page 44: Other Commands

    PLC-WTC500L Expand Serial Command Functional Specifications 8.11 Other Commands 8.11.1 CF_KEYEMU Command Command “CF_KEYEMU_%1” [CR] “RIGHT” ---------------- Move Pointer rightward in On-Screen Display Menu “LEFT” ------------------ Move Pointer leftward in On-Screen Display Menu “UP” ---------------------- Move Pointer to upward On-Screen Display Menu “DN”...
  • Page 45: Cf_Freeze Command

    PLC-WTC500L Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command “CF_FREEZE_%1” [CR] “ON” --------------------------- Set Freeze to ON. “OFF” ------------------------- Set Freeze to OFF. “UP” --------------------------- Switch forward (On→Off→On→---) “DN” --------------------------- Switch backward (On→Off→On→---) * The same operation for “UP” and “DN” as this model has only “ON” / “OFF”. Set / Cancel Freeze function.
  • Page 46: Status Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9ÿ Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
  • Page 47: Cr_Tint Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.4.4 CR_TINT Command Command “CR_TINT” [CR] Details Get user controlled value of Tint Acceptable “000_%1” [CR] “000 – 063” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input). “?”...
  • Page 48: Cr_Coltemp Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.4.10 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1” [CR] “000” --------------------------------- Xlow “001” --------------------------------- Low “002” --------------------------------- Mid Response “003” --------------------------------- High “BLANK” ---- Processing adjusting White Balance (Neither of Xlow / Low / Mid / High) Unacceptable “Error code”...
  • Page 49: Cr_Imggmd Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.4.14 CR_IMGGMD Command Command “CR_IMGGMD” [CR] Details Get setting status of Dynamic/Standard/Real/Cinema in Image Gamma Acceptable “000_%1” [CR] “DYN” ------------ Dynamic “STD” ------------ Standard Response “REL” ------------ Real “CNM” ------------ Cinema Unacceptable “Error code” [CR] 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command...
  • Page 50: Cr_H-Pos Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.5.4 CR_H-POS Command Command “CR_H-POS” [CR] Details Get value of Horizontal Position Acceptable “000_%1” [CR] “0000 – nnnn” (nnnn = Total Dots – Display area H) Response “Error Code” [CR] ------ When command is not available in the Unacceptable given condition (such as being selected input “?”...
  • Page 51: Cr_Orgmode Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-60 is not selected, get the current signal. Acceptable “000_%1”...
  • Page 52: Cr_Setpcadj Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.5.10 CR_SETPCADJ Command Command “CR_SETPCADJ” [CR] Details Get PC signal for current system Acceptable “000_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Indicates VGA1 is selected “VGA2” ------------------------ Indicates VGA2 is selected “XGA1”...
  • Page 53: Input Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected INPUT No. Acceptable “000_%1” [CR] Response “1 – 4” Unacceptable “Error code” [CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected source Acceptable “000_%1”...
  • Page 54: Cr_Srcinp3 Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7.5 CR_SRCINP3 Command Command “CR_SRCINP3” [CR] Details Get Source of INPUT3 Acceptable “000_%1” [CR] “VIDEO” ------------- in Video mode Response “S-VIDEO” ---------- in S-Video mode Unacceptable “Error code” [CR] 9.7.6 CR_SRCINP4 Command Command “CR_SRCINP4” [CR] Details Get Source of INPUT4 Acceptable...
  • Page 55: Cr_System Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7.7 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] “VGA1” ------------------------- indicates VGA1 is selected “VGA2” ------------------------- indicates VGA2 is selected “XGA1” ------------------------- indicates XGA1 is selected “WXGA3” ---------------------- indicates WXGA3 is selected “1080I”...
  • Page 56: Cr_Syslist Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] When Input is PC Analog: “XGA” ------------------- XGA is in the list “1080I” ----------------- 1080i is in the list *Auto, Mode1-10 shall not be returned.
  • Page 57: Cr_Hmslot Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command Command “CR_NMSLOT1”...
  • Page 58: Cr_Idslot1 Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “33” --------------- On-board (D-Sub + HDMI) Response Available source: ANALOG, SCART, HDMI Unacceptable “Error Code”...
  • Page 59: Screen Status Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “ZOOM” -------------------------- Zoom mode “NATURAL” ---------------------- Natural wide mode “WIDE” --------------------------- Wide mode Response “FULL”...
  • Page 60: Cr_Vpos Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.8.6 CR_VPOS Command Command “CR_VPOS” [CR] Details Get setting status of V Position Acceptable “000_%1” [CR] Response “-15”ÿ ”015” Unacceptable “Error Code” [CR] 9.8.7 CR_HSCALE Command Command “CR_HSCALE” [CR] Details Get setting status of H scale Acceptable “000_%1”...
  • Page 61: Lamp Status Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “2Y” ----------------- indicates over lamp replacement time “2N” ----------------- indicates under lamp replacement time “2”...
  • Page 62: Cr_Lampmode Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.9.4 CR_LAMPMODE Command Command “CR_LAMPMODE” [CR] Details Get setting status of Lamp control Acceptable “000_%1” [CR] “AUTO1” ------------------ Lamp control is Auto1 “AUTO2” ------------------ Lamp control is Auto2 “HIGH” -------------------- Lamp control is High Response “NORMAL”...
  • Page 63: Cr_Lampcontrl Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.9.8 CR_LAMPCONTRL Command Command “CR_LAMPCONTRL” [CR] Details Get setting status of Lamp mode Acceptable “000_%1” [CR] “LAMP1” ------------------ Lamp mode is Lamp1 Response “LAMP2” ------------------ Lamp mode is Lamp2 “CHANGE” --------------- Lamp control is Lamp1/2 Unacceptable “Error Code”...
  • Page 64: Sound Status Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME”[CR] Details Get Volume value of user control Acceptable “000_%1”[CR] Response “000”~“063” Unacceptable “Error Code” [CR] 9.10.2 CR_MUTE Command Command “CR_MUTE”[CR] Details Get sound mute setting status Acceptable “000_%1”[CR] “ON”...
  • Page 65: Setting Status Read Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
  • Page 66: Cr_Pipsize Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.5 CR_PIPSIZE Command Command “CR_PIPSIZE” [CR] Details Get screen size of Picture in Picture Acceptable “000_%1” [CR] “SMALL” ---------------------------- Small is selected Response “MIDDLE” --------------------------- Middle is selected “LARGE” ---------------------------- Large is selected Unacceptable “Error Code”...
  • Page 67: Cr_Rcode Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.9 CR_RCODE Command Command “CR_RCODE” [CR] Details Get selected Remote Control Code Acceptable “000_%1” [CR] “001” --------------------------- Code 1 is selected “002” --------------------------- Code 2 is selected “003” --------------------------- Code 3 is selected “004” --------------------------- Code 4 is selected Response “005”...
  • Page 68: Cr_Standbymode Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.13 CR_STANDBYMODE Command Command “CR_STANDBYMODE” [CR] Details Get setting status of Standby mode Acceptable “000_%1” [CR] “ECO” --------------------------- Eco mode is selected Response “NORMAL” --------------------- Normal mode is selected Unacceptable “Error Code” [CR] 9.11.14 CR_P-MANE Command Command “CR_P-MANE”...
  • Page 69: Cr_Slant Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.18 CR_SLANT Command Command “CR_SLANT”[CR] Details Get setting status of Slant setting Acceptable “000_%1”[CR] “OFF” ------------ Slant is Off “L1” -------------- L1 mode is selected Response “L2” -------------- L2 mode is selected “L3” -------------- L3 mode is selected “L4”...
  • Page 70: Cr_Hdmisound Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.23 CR_HDMISOUND Command Command “CR_HDMISOUND” [CR] Details Get setting status of HDMI setup – Sound. Acceptable “000_%1” [CR] “HDMI” ----------------- PCM input(Digital sound) is selected Response “EXTERNAL” --------- External sound input is selected Unacceptable “Error Code”...
  • Page 71: Cr_Testpat Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.28 CR_TESTPAT Command Command “CR_TESTPAT” [CR] Details Get setting status of Test pattern Acceptable “000_%1” [CR] “COLOR” ---------------------- Color bar is displayed “GRAD1” ---------------------- 16step(white→black) is displayed “GRAD2” ---------------------- 16step(white←black) is displayed “GRAD3” ---------------------- 16step(white↓black) is displayed Response “GRAD4”...
  • Page 72: Cr_Filremain Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.11.33 CR_FILREMAIN Command Command “CR_FILREMAIN” [CR] Details Get remaining number of usable Filter scroll Acceptable “000_%1” [CR] “09” = Remaining number of usable Filter scroll : 9 times Response ÿ “00” = Remaining number of usable Filter scroll : 0 time Unacceptable “Error Code”...
  • Page 73: Other Status Read Commands

    PLC-WTC500L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 74: Cr_Tempfail Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
  • Page 75: Cr_Temp Command

    PLC-WTC500L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.