Installation Instructions
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Household Water Filtration Housing.
Using a qualified installer is recommended.
Be sure the water supply conforms with the Specifications
Guidelines. If the water supply conditions are unknown,
contact your municipal water company.
This Household Water Filtration System must be properly installed and located in accordance with the Installation Instructions before it is used.
Check with your local public works department for plumbing
codes. You must follow their guides as you install the Household
Water Filtration System.
Use the Household Water Filtration System on a potable, safe-
to-drink, home COLD water supply only. The filter cartridge will
not purify water or make unsafe water safe to drink.
Protect the Household Water Filtration System and piping from
freezing. Water freezing in the housing will damage it.
Your Household Water Filtration System will withstand up to 125
psi water pressure. If your house water supply pressure is higher
than 80 psi during the day (it may reach higher levels at night),
install a pressure-reducing valve before the housing is installed.

REQUIRED TOOLS AND ACCESSORIES

FOR INSTALLATION
2 wrenches: 1
and 1
1 8
1 4
Pipe cutter
Ruler or tape measure
Cordless drill and a 3/16 drill bit (optional)
File
Emery paper
Screwdriver
The FXUSC (Rev. 2) filter is tested and
certified by NSF International against
NSF/ANSI Standard 42 for materials
requirement only.
COMPONENT

SAFETY PRECAUTIONS

PROPER INSTALLATION

(2)
compression adapters with ferrule
3 4
and nut (compatible to home plumbing)
UL-approved grounding clamps and
6-gauge grounding wire
Teflon tape
If unit is to be installed on plastic,
PVC or galvanized plumbing, separate
hardware must be purchased.
This GXWH04F is tested and certified
by NSF International against NSF/ANSI
Standard 42 for materials and structural
integrity requirements only.
49-50202-3 (
GEAppliances.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
Household Water Filtration System*
WARNING:
microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
It is highly recommended that a water shut-off valve be placed
directly upstream of your household filter.
Do not install on HOT WATER. The temperature of the water
supply to the Household Filtration System must be between the
minimum of 40°F and the maximum of 100°F. See the Specification
Guidelines.
Do not install the Household Water Filtration System using copper
solder fittings. The heat from the soldering process will damage the
unit. If making a soldered copper installation, do all sweat soldering
before connecting pipes to the housing. Torch heat will damage
plastic parts.
WARNING:
material after installation. Small parts remaining after installation
could be a choke hazard.
Do not install filter in an outside location or anywhere it will be
exposed to sunlight.
COMPONENT
10-12 GE)
GXWH04F and GXWH20S
Do not use with water that is
Discard all unused parts and packaging

CONTENTS INCLUDED WITH PRODUCT

Filter housing and head
Product literature
Sediment filter FXUSC (Rev. 2)
(for GXWH20S only)
Housing wrench
Mounting bracket with (2) screws
Timer and batteries
The GXWH20S system using FXUSC (Rev.
2) filter is tested and certified by NSF
International against NSF/ANSI Standard
42 for reduction of particulate Class V.
The GXWH20S has been tested and
Certified by WQA according to CSA
B483.1.

Advertisement

Table of Contents
loading

Summary of Contents for GE GXWH20S

  • Page 1: Safety Precautions

    42 for reduction of particulate Class V. COMPONENT COMPONENT The GXWH20S has been tested and Certified by WQA according to CSA B483.1. 49-50202-3 ( 10-12 GE) GEAppliances.com GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225...
  • Page 2 For filter replacement, see chart above for individual 4 Inspect the filter canister O-ring. Make sure it is lightly filter flush times. lubricated with clean food-grade silicone grease (silicone grease is available through GE Parts and GXWH04F GXWH20S Service: 1.800.626.2002, part number WS60S10005).
  • Page 3 STEP-BY-STEP INSTALLATION INSTRUCTIONS GXWH20S Installation Overview GXWH04F NOTE: Be sure to allow a minimum space of 1 ”– Recommended Recommended 2” under the filter for removing the filter housing shut-off valve shut-off valve to change the cartridge. Recommended shut-off valve Recommended shut-off valve ”–2”...
  • Page 4 STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.) Attach Fittings to Water Line 1 Slip a compression nut onto each pipe. 2 Next, slip the brass ferrule onto each pipe. Brass ferrule Brass ferrule Hex nut Hex nut Installing the Unit 1 Align filter assembly with pipe ends, making certain that the 3 Hang mounting bracket with unit onto previously installed incoming water supply is going into the filter opening marked screws.
  • Page 5: Parts List

    PARTS LIST Ref. No. Part No. Part Description WHTIMER Timer WS03X10038 O-Ring WX5X140 Housing Wrench 49-50202-3 Installation Instructions To obtain replacement parts, call toll-free 800.626.2002 (U.S.), LIMITED ONE-YEAR WARRANTY What does this warranty cover? How do I make a warranty claim? of the “Proof of Purchase.”...
  • Page 6 V. COMPOSANTE COMPOSANTE Ce GXWH20S a été testé et certifié par la WQA selon les normes CSA B483.1. 49-50202-3 ( 12-12 GE) GEAppliances.com GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225...
  • Page 7 (vous trouverez la graisse de silicone au Minuterie GXWH04F GXWH20S service de pièces et d’entretien GE, en téléphonant Bouton rouge de Minuterie au 1.800.626.2002, numéro de pièce WS60S10005). dépressurisation Assurez-vous que le joint torique repose bien dans Tête...
  • Page 8 ÉTAPES DE L’INSTALLATION GXWH20S Illustration de l’installation GXWH04F NOTE: Veiller à ce qu’il y ait un espace libre d’au moins Robinet d’arrêt– 3,8 à 5,1 cm (1 1/2 à 2 po) sous le filtre pour l’extraction recommandé Robinet d’arrêt– du logement de filtre lors du changement de la recommandé...
  • Page 9 Placez les attaches en bronze sur la tuyauterie en cuivre. Serrez les vis. ou en métal galvanisé pour effectuer une liaison à la terre des prises électriques de la maison. Cette mise à la masse vous protège contre les Fixez le fil sur les attaches comme indiqué. Serrez les vis.
  • Page 10 État ou le procureur général de votre État. Contactez nous sur ge.com, ou appelez le numéro sans frais 800.952.5039 aux États-Unis. Au Canada, contactez nous sur www.electromenagersge.ca, ou appelez le numéro sans frais 866.777.7627.
  • Page 11 NSF Internacional contra el Estandard 42 NSF/ los Estándares NSF/ANSI 42 para los estructural solamente. requisitos de materiales solamente. COMPONENTE COMPONENTE Este GXWH20S es sido puesto a prueba CSA B483.1. 49-50202-3 ( 12-12 GE) GEAppliances.com GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225...
  • Page 12 Botón rojo Cronómetro para reducir la disponible a través del departamento de Partes y Servicio presión de GE llamando al 1.800.626.2002, número de parte Manija Botón rojo WS60S10005). Cerciórese de que el aro tórico está en de control para reducir la la ranura.
  • Page 13 INSTRUCCIONES DE INSTALACION PASO A PASO GXWH20S Sumario de la instalación GXWH04F NOTA: Asegúrese de dejar un espacio mínimo de entre recomendada recomendada recomendada recomendada 3.8-5.1 cm (1 1/2”-2”) 3.8-5.1 cm (1 1/2”-2”) Seleccione la ubicación Se recomienda instalar una válvula de cierre en ambos lados del filtro. Se recomienda el uso de un soporte de montaje.
  • Page 14 INSTRUCCIONES DE INSTALACION PASO A PASO (cont.) Conecte las uniones a la línea del agua Deslice una tuerca de compresión en cada cañería. Férula de Férula de Tuerca Tuerca bronce bronce Instalación de la unidad asegurándose que la entrada de la línea del agua vaya hacia la abertura marcada “IN”...
  • Page 15 Attorney General en su localidad. Póngase en contacto con nosotros en ge.com, o llame sin cargo al 800.952.5039, o 866.777.7627 en Canada.
  • Page 16 Notes...

This manual is also suitable for:

Gxwh04f

Table of Contents