Hitachi L200 Series Service Manual page 35

Hide thumbs Also See for L200 Series:
Table of Contents

Advertisement

ERROR Check
error
No display
E08/E11
E22
8888 display
OC trip/E23/
E30/E14
----
(Power Off
display)
E09 with
motor
E12(EXT)
E35(PTC)
E05(Over
Load),OC
trip(L200)is prematured
Cooling
FAN
doesn't
work
INV doesn't work
MOV failure, or you got
returned INV
bar-bar-bar-bar
display(OPE-S,OPE-SRE,
not OPE-Smini)
or
R-ERROR
COMM.<1>(SRW)
No display
description
DC bus charged
IO board connection & cable connection
OPE connection
short bar P1- PD
Cooling FAN failure
Connection between IO board & OPE(L200)
EEPROM recovery(initilalization
IO board connection & cable connection(communication error
between ISPM & IO board)
INV type code is wrong SJ200 & L200
EEPROM
recovery(initilalization
11d4=ff)(because MCU can't read EEPROM)
EEPROM data changed.
Disconnect motor wire and check output voltage
Core(ISPM) failure(not repairable)
maybe thyristor off, please check waveform of DC bus voltage.
check C01-C06 (EXT=12)
check C06(SJ200)-C05(L200)(PTC=19) ,check C85 value
check
b32 value
check b92
check DIP switch on ISPM(Power Module pcb)
check d109 display after C91 set 01
Set dip Switch from 485 to PRG
check the bar of P-line.
C92
display 11d4=ff)
C92
check C194
2-2
display

Hide quick links:

Advertisement

Table of Contents
loading