CALIBRATION AND SETUP, CONT.
CA
LIBRATE
With th
e SETUP MENU #1 displayed, press NEXT (Navigation Keys
procee
d to SETUP MENU #2.
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP S
5. CALIBRATE 1
Enter Selection: 0
5. C
ALIBRATE 1
With the SETUP MENU #2 displayed, press the 5 key and then the ENTER key to proceed
to S
CALE 1 CALIBRATION MENU.
1. Swt= XXXXXXX
2. Sct= XXXXXXX
3. Zct= XXXXXXX
4. FINE SPAN
5. HI RES
Enter Selection: 0
1. Swt=XXXXXXX (SPAN WE
2. Sct=
XXXXXXX (SP
3. Zct=XXXXXXX (ZERO COUNT)
ation parameters (Swt, Sc
The calibr
analog to digital readings at zero and test load. These values are established when the
scale is ca
librated. By recording the parameter values, the indica
present calibration settings without using test weights simply by entering the values.
6. C1=XXX
7. C2=XXX
8. C3=XXX
9. C4=XXX
The calibration "C" numbers (C1, C2, C3 and C4) represent the present calibration
settings. Each number may be up to three digits in length. The "C" numbers are
established when the scale is calibrated. By recording these numbers, the indicator can be
returned to its present calibration settings without using test weights simply by entering the
"C" numbers.
8200-M538-O1 225 Installation
SETUP MENU #2
CALE 1
SCALE 1 CALIBRATION MENU
IGHT)
AN COUNT)
t and Zct) represent the test load (weight) and the
CALIBRATION "C" NUMBERS
^
PREV
`
EXIT
6. C1=XXX
7. C2=XXX
8. C3=XXX
9. C4=XXX
10. CALIBRATE
^
EXIT
CALIBRATION PARAMETERS
Down Arrow) to
tor can be returned to its
Page 62
Need help?
Do you have a question about the 225 and is the answer not in the manual?
Questions and answers
Our weighing scale monitor indicate low analog