Carrier 24APA7 Performance Product Data page 21

Performance 17 2-stage air conditioner with puron refrigerant 2 to 5 tons
Hide thumbs Also See for 24APA7 Performance:
Table of Contents

Advertisement

COMBINATION RATINGS CONTINUED
AHRI
Model Number
Ref. No.
3638195
24APA760A**31
3877978
24APA760A**31
3877979
24APA760A**31
3638249
24APA760A**31
3638248
24APA760A**31
4213277
24APA760A**31
3638176
24APA760A**31
3638239
24APA760A**31
3638241
24APA760A**31
3638232
24APA760A**31
3638238
24APA760A**31
3638240
24APA760A**31
3638230
24APA760A**31
3638231
24APA760A**31
3638203
24APA760A**31
3638204
24APA760A**31
3638250
24APA760A**31
4213280
24APA760A**31
3638179
24APA760A**31
3638224
24APA760A**31
3638201
24APA760A**31
3638202
24APA760A**31
3638221
24APA760A**31
3638222
24APA760A**31
3638223
24APA760A**31
3638205
24APA760A**31
3638206
24APA760A**31
EER
Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR
— Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
TXV
— Thermostatic Expansion Valve
UI
— User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
Coil
Furnace
Model Number
Model Number
CNPV*6124A**
58PH*135---20
CNPV*6124A**
58UVB100---20
CNPV*6124A**
58UVB120---20
CNPV*6124A**
58VLR120---20
CNPV*6124A**
58VMR120---20
CNPV*6124A**
OVLAAB060154
CNPV*6124A**+TDR
CNPV*6124A**+UI
58CV(A,X)110---20
CNPV*6124A**+UI
58CV(A,X)135---22
CNPV*6124A**+UI
58CV(A,X)155---22
CNPV*6124A**+UI
58MV(B,C)100---20
CNPV*6124A**+UI
58MV(B,C)120---20
CSPH*6012A**
58ME(B,C)100---20
CSPH*6012A**
58ME(B,C)120---20
CSPH*6012A**
58PH*110---20
CSPH*6012A**
58PH*135---20
CSPH*6012A**
58VMR120---20
CSPH*6012A**
OVLAAB060154
CSPH*6012A**+TDR
CSPH*6012A**+UI
58CV(A,X)110---20
CSPH*6012A**+UI
58CV(A,X)135---22
CSPH*6012A**+UI
58CV(A,X)155---22
CSPH*6012A**+UI
58MV(B,C)080---20
CSPH*6012A**+UI
58MV(B,C)100---20
CSPH*6012A**+UI
58MV(B,C)120---20
FE4ANB006+UI
FV4CNB006
Cooling
Capacity
High
Low
59,000
47,500
58,500
47,500
59,000
47,500
59,500
47,500
59,000
47,500
59,000
48,000
59,500
47,500
59,000
48,000
59,500
48,000
59,500
48,000
58,500
47,500
59,000
47,500
58,500
47,000
59,000
47,000
59,000
47,000
58,500
47,000
58,500
47,500
58,500
47,500
59,000
47,000
58,500
47,500
59,000
47,500
59,000
47,500
58,000
47,000
58,000
47,500
58,500
47,500
59,500
48,000
59,500
48,000
21
ID CFM
EER
SEER
High
Low
13.1
16.5
1,675
1,290
12.5
15.5
1,660
1,395
12.8
16.0
1,680
1,360
12.9
16.5
1,735
1,350
12.5
16.0
1,740
1,355
11.7
15.5
2,110
1,675
12.8
15.0
1,750
1,400
13.0
16.0
1,695
1,355
13.2
16.5
1,685
1,355
13.3
16.5
1,705
1,365
12.5
15.5
1,660
1,395
12.8
16.0
1,680
1,360
13.1
16.5
1,650
1,270
13.2
16.5
1,660
1,290
13.1
16.5
1,710
1,270
13.0
16.5
1,675
1,275
12.4
16.0
1,740
1,355
11.7
15.2
2,110
1,675
12.7
15.0
1,750
1,400
12.9
16.0
1,695
1,355
13.1
16.5
1,685
1,355
13.2
16.5
1,705
1,365
12.2
15.5
1,730
1,310
12.4
15.5
1,660
1,395
12.7
16.0
1,680
1,360
13.4
17.0
1,750
1,400
13.4
16.5
1,750
1,400