Installation - Zanussi ZFC620WAP User Manual

Chest freezer
Hide thumbs Also See for ZFC620WAP:
Table of Contents

Advertisement

Installation

Positioning
This appliance can be installed in a dry, well ventilated
indoor (garage or cellar), but for optimum performance
install the appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on the
rating plate of the appliance:
Climate
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Ventilation requirements
1. Put the freezer in horizontal position on a firm surface.
The cabinet must be on all four feet.
2. Make sure that the clearance between the appliance
and rear wall is 5 cm.
3. Make sure that the clearance between the appliance
and the sides is 5 cm.
The airflow behind the appliance must be sufficient.
Electrical Connection
Caution! Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
Warning! This appliance must be earthed.
The manufacturer declines any liability should these
safety measures not be observed.
6
Ambient temperature
1
Important! The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow:
1
3
Brown:
5
Blue:
As the colours of the wires in the mains lead of this ap-
pliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
1. Connect the wire coloured green and yellow to the
terminal marked either with the letter "E" or by the
earth symbol
or coloured green and yellow.
2. Connect the wire coloured blue to the terminal either
marked with the letter "N" or coloured black.
3. Connect the wire coloured brown to the terminal ei-
ther marked with the "L" or coloured red.
4. Check that no cut, or stray strands of wire is present
and the cord clamp
sheath.
5. Make sure the electricity supply voltage is the same
as that indicated on the appliance rating plate.
6. Switch on the appliance.
The appliance is supplied with a 13 amp plug fitted
In the event of having to change the fuse in the plug sup-
plied, a 13 amp ASTA approved (BS 1362) fuse must be
used.
2
3
4
5
Earth
Live
Neutral
4
is secure over the outer
2
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zfc639wap

Table of Contents