24 | KTS 200 | Operation
5.5

Software update

The software update is either performed using the
"ESI[tronic] Startcenter" DVD or "online".
The online software update (section 5.5.2) can only
be performed with ESI[tronic] Startcenter version
2007/3 or later.
5.5.1
Software update using the ESI[tronic]
Startcenter DVD
Insert the "ESI[tronic] Startcenter" DVD in the DVD
1.
drive (e.g. "D:\") on the PC/laptop.
Open the "Run" input field (select "Start >> Run..."
2.
in the taskbar).
Enter
D:\setup.exe
3.
clicking <OK>.
The Setup routine is started.
Follow the installation instructions on the screen.
When installation is complete, restart the computer.
4.
Windows is shut down and ESI[tronic]
Startcenter is restarted.
Connect the KTS 200 to the PC using the USB con-
5.
necting lead.
Connect the KTS 200 to the mains using the power
6.
pack supplied.
The KTS 200 starts up.
During the software update, the USB connection
and the power supply to the KTS 200 may not be
broken.
ESI[tronic] Startcenter: Open "KTS 200 >> Device
7.
information".
Select an available update.
8.
Select <Update>.
9.
The system software is installed on the KTS 200.
|
1 689 989 001
2007-05-30
and confirm by
5.5.2

Online software update

Start "ESI[tronic] Startcenter".
1.
Open the "Settings >>Online updates" input
2.
window.
Enter the customer number and password and
3.
select <Next>.
If "Login" is not possible, check your proxy
settings under "Settings >> User settings".
Select an available update and start the software
4.
update.
Follow the installation instructions on the screen.
5.
When installation is complete, restart the computer.
6.
Windows is shut down and ESI[tronic]
Startcenter is restarted.
7.
Connect the KTS 200 to the PC using the USB
connecting lead.
Connect the KTS 200 to the mains using the power
8.
pack supplied.
The KTS 200 starts up.
During the software update, the USB connection
and the power supply to the KTS 200 may not
be broken.
ESI[tronic] Startcenter: "KTS 200 >> Device
9.
information".
Select an available update
10.
11.
Select <Update>.
The system software is installed on the KTS 200.
5.6

Faults

The KTS 200 may not be opened. Opening the
KTS 200 erases its licensing data. It is then no
longer possible to perform control unit diagnosis.
No communication with the control unit
The fault message "No system found" appears during
control unit diagnosis.
Possible causes
What can you do?
Incorrect lead
Check whether the correct
connected.
lead has been used.
Incorrect pin selected
Under "Start >> Diagnostic socket",
in pin selection menu
check which pin has to be used.
If problems of a different nature occur, please
contact the ESI[tronic] service hotline directly.