Bogen Classic C100 Installation And Use Manual

Bogen Classic C100 Installation And Use Manual

Classic series amplifiers
Hide thumbs Also See for Classic C100:

Advertisement

Classic Series Amplifiers
C35, C60, & C100 Models
Installation and Use Manual
© 2009 Bogen Communications, Inc.
All rights reserved.
Specifications subject to change without notice.
54-5979-02E 1203

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Classic C100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bogen Classic C100

  • Page 1 Classic Series Amplifiers C35, C60, & C100 Models Installation and Use Manual © 2009 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5979-02E 1203...
  • Page 2 Notice: Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. However, information is subject to change. WARNING: To reduce the risk of Fire or Electric Shock, Do Not Expose this apparatus to rain or moisture.
  • Page 3: Table Of Contents

    Contents Page PANEL DESCRIPTIONS ....................2-3 Classic Series Front Panel ..................2 Classic Series Rear Panel ..................3 INSTALLATION ........................4 Package Contents....................4 Ventilation ......................4 Rack Mounting ......................4 CONNECTIONS ........................5 Input Connections ....................5 Microphone Connections ................5 Auxiliary ......................5 AUX Muting ....................5 TEL ........................5 Output Connections ....................5 Speakers, General ..................5 Speakers, Low-Impedance................5 Tape/Booster Connection ................5...
  • Page 4: Panel Descriptions

    Panel Descriptions Classic Series Front Panel 1. MIC1 Level Control Individual level control for a dedicated microphone input. 2. MIC2/AUX1 Mode Switch Switch selects either the MIC2 or AUX1 connection as the active input. 3. MIC2/AUX1 Level Control Individual level control for a dedicated microphone input or for an auxiliary input depending on input mode selected.
  • Page 5: Classic Series Rear Panel

    2. Tape/Booster RCA unbalanced signal level/output. 3. WMT1A RCA output connection for Bogen’s 600-ohm balanced line matching transformer Model WMT1A. 4. AUX Terminal Screw terminal connection that allows externally controlled muting of AUX inputs with a contact closure. 5. Microphone Inputs Screw terminal strip containing the MIC1 and MIC2 balanced, low-impedance inputs.
  • Page 6: Installation

    Installation Package Contents • Classic Series Amplifier • Instruction Manual Ventilation When using a shelf or table mount, the amplifier should stand alone with no equipment on top of it or below it. Rack Mounting A rack mount bracket kit (Model RPK50) is available as an accessory. (Not included.)
  • Page 7: Connections

    WMT1A Connection This output jack is directly connected to the 25V speaker tap and permits the connection of Bogen’s general-purpose matching trans- former (WMT1A). The WMT1A steps the signal down by a 5:1 ratio, giving you a 600-ohm balanced signal that can drive long cable runs.
  • Page 8: Operation

    Operation Front Panel Controls Power The front panel ON/OFF switch applies power to the amplifier and is illuminated when power is ON. Input Volume Controls Each input module may be individually controlled by its corresponding volume control knob. MIC2, AUX 1 Mode Switch Activates the corresponding input that it is switched to, MIC2 or AUX1.
  • Page 9: Rear Panel Controls

    Operation Rear Panel Controls TEL Volume Control The TEL VOLUME control on the rear panel adjusts the TEL input’s paging level. It does not affect the microphone level. Rotate the control counterclockwise to decrease the level. Rotate the control clockwise to increase the level.
  • Page 10: Specifications

    Specifications Power Output (RMS) C35: C60: C100: 100W Frequency Response & Distortion Transformer 70 Hz to 16 kHz (± 2 dB) @ 1% max. † 4-Ohm Direct Output: 20 Hz to 20 kHz (± 1 dB) @ 0.5% max. Hum and Noise MIC Input: 55 dB below rated output AUX Input:...
  • Page 11: Troubleshooting

    Troubleshooting PROBLEM CONDITION CAUSE • Amplifier not plugged in. • AC outlet dead. Power Switch Indicator is OFF. • Power switch off. • Circuit breaker tripped. NO SOUND • No signal from source. • Volume turned down. Power Switch Indicator is ON. •...
  • Page 12: Limited Warranty

    In no event shall Bogen be liable for special, incidental or con- sequential damages (including, but not limited to, loss of profits, loss of data or loss of use damages) arising out of the manufacture, sale or supplying of products, even if Bogen has been advised of the possibility of such damages or losses.