Page 3
Thank you tor purchasing a Honda generator. This manual covers operation and maintenace of EG1400X and EG2200X generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd.
1 .CAUTION LABEL LOCATION )XIIIE POISON,NG, CARBON MONOXIOE CAUTION LABEL ROT USE lNo00RS DUE TO OAffiER Of CAGGON NE PAS UTILISER OANS UN ENOROll fERME A CAUSE OU ATTENTION RLSGUE D’EMPOISONNEMENT OU GAZ. NO LO USE EN LUG ATENCION DE CARBON0 ES VE OIL LEVEL LABEL ls===i...
2.GENERATOR SAFETY To ensure safe operation Place the generator at least 1 m (3 ft) away from buildings or other equip- ment during operation. Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. Exhaust gas contains poisonous...
1. Check the engine oil level. CAUTION: Engine oil is a major factor affecting engine performance service life. Nondetergent or vegetable oils are not recommended. Use Honda 4-stroke oil, or an equivalent high detergent, premium quality motor oil certified to meet or exceed U.S.
Page 10
If spark knock pinging persists, consult your authorized Honda dealer. Failure to do so is considered misuse, and damage caused by misuse is not covered Honda’s Limited Warranty. Occasionally you may experience...
Page 11
(gasohol), be sure it’s cotane rating is at least as high as that recommended by Honda. There are two types of “gasohol”: one containing ethanol, and the other containing methanol. Do not use gasohol that contains more than 10% ethanol.
5.STARTING THE ENGINE Disconnect load from terminals and make sure that the AC circuit breaker is in the OFF posi- tion. (2) Turn on the fuel valve, (3) Turn on the engine switch.
Page 13
(4) Move the choke lever totheCLOSED position. (5) Pull starter rope lightly until resistance is felt, then pull briskly. CAUTION: allow starter grip to snap back. Return it slowly hand. (6) Move the choke lever to the OPEN position as the engine warms...
If you always operate the generator at altitudes highter than 6,000 feet above sea level, have your authorized Honda Generator deafer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower...
6.GENERATOR prevent elecrical shock from faulty appliances, generator should be grounded. Connect a length of heavy wire between generator’s ground terminal and an external ground source. Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with...
Page 16
AC applications 1. Start the engine and plug in the appliance; always use three-pronged plugs. 2. Switch on the AC Circuit Breaker. CAUTION: Substantial overloading will switch off the circuit breaker. Mar- ginal overloading may not switch off the circuit breaker, but it will shorten the service life of the generator.
Page 17
DC application The DC terminals may be used for charging 12 volt automotive-type batteries only. battery gives explosive gases; keep sparks, flames cigarettes away. Provide adequate ventilation when charging or using batteries in an enclosed space. The battery contains sulfuric acid (electrolyte).
Page 18
CAUTION: Do not attempt to start an automobile engine while the generator is still connected to the battery. The generator may be damaged. Connect the positive battery terminal to the positive generator terminal. not reverse the charging cables, or serious damage to the generator and/or battery may occur.
7.STOPPlNG THE ENGINE (1) Turn off the AC circuit breaker disconnect any charging leads at the DC terminals. (2) Turn the engine switch to the OFF position. (3) Turn the fuel valve to the OFF posi- tion.
If the engine must be run, make sure the area is well ventilated. The exhaust con- tains poisonous carbon monoxide gas. CAUTION: Use genuine HONDA parts or their equivalent. The use of re- placement parts which equivalent quality may damage generator.
Page 21
NOTE (1) : Service more frequently when used in dusty areas. (2) : These items should be serviced by an authorized Honda dealer, unless the owner has the proper tools and is mechanically proficient. See the Honda Shop Manual.
Page 22
Changing Drain the oil while the engine is still warm to assure rapid and complete draining. 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely. 2. Refill with the recommended oil (see page 7) and check the level. OIL CAPACITY: 0.6 P (0.63 USqt) OIL DRAIN...
Page 23
Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent car- buretor malfunction, service the air cleaner regularly (page 19). Service more frequently when operating the generator in extremely dusty areas. Never use gasoline or low flash point solvents for cleaning...
Page 24
Sediment The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the cup should be cleaned. 1. Turn the fuel valve OFF. Remove the sediment cup.
Page 25
Spark plug service Recommended spark plug: BPGES, BPRGES (NGK) W20EP-U, W20EPR-U (ND) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
Page 26
6. Attach the plug washer and thread the plug in by hand to prevent cross threading. 7. After a new spark plug has been seated by hand, it should be tightened l/2 turn with a wrench to compress its washer. If a used plug is being reinstalled, it should...
Page 27
Spark arrester maintenance. If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. CAUTION: The spark arrester must be serviced every 100 hours to maintain its efficiency. 1. Loosen 0 two 8 mm nuts and @ 8mm bolt to remove the @ muffler assembly.
9.TRANSPORTING/STORAGE When transporting the generator, turn the engine switch and the fuel valve and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. Before storing the unit for an extended period: 1. Be sure the storage area is free of excessive humidity and dust.
lO.TROUBLESHOOTING When the engine will not start: Refill the fuel tank. Turn the engine Turn the fuel Is the fuel valve on? Add the recom- in the engine? (The oil alert lamp goes on when pulling the starter grip) y$hge pE?zE%...~~ 1) Remove the spark plug cap and and clean any dirt from around...
Page 30
Take the generator Check the electrical NO DEFECTS appliance or equip- to an authorized ment for any defects HONDA dealer. - Replace the elect- rical appliance equipment. - Take the electrical DEFECTS appliance or equip- ment to an elect- r ical shop for repair.
Length x Width x Height (18.7 x 15.4 x 15.7 in) (19.9 x 16.1 x 16.3 in) Dry Weight 31.0 kg (68.4 lb) 37.0 kg (81.6 lb) Engine Model HONDA GXllO HONDA GX140 Engine Type 4-Stroke, O.H.V. 1 cylinder (25O tilted) Displacement 107 cm3 (6.6 cu.in)
Your purchase of a Honda product is greatly appreciated by both your dealer and American Honda Motor Co., Inc. We want to assist you in every...
Page 34
When you write or call, please provide the following information: • Model and serial numbers • Name of the dealer who sold the Honda power equipment to you • Name and address of the dealer who services your equipment •...
Need help?
Do you have a question about the EG2200X and is the answer not in the manual?