  • Page 1 Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 EBAC MODEL BD-150 (1024500) INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL BD-150 OWNERS MANUAL Page 1 of 12...
  • Page 2 Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 INTRODUCTION Designed for a wide range of applications, the BD-150 dehumidifier is a super high capacity industrial unit which provides fast and efficient drying. The BD-150 has a number of special features: •...
  • Page 3: Specifications

    Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 SPECIFICATIONS BD-150 ODEL 36” EIGHT 24” IDTH 25” EPTH 165 lb EIGHT 1114 CFM IRFLOW 115V/ 60Hz/ 1 ph OWER UPPLY Powder-coated Epoxy INISH 41°F – 100°F PERATING ANGE R-22 (19 oz) EFRIGERANT BD-150 OWNERS MANUAL Page 3 of 12...
  • Page 4: Operation

    Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 OPERATION The following procedures should be followed to test the BD-150 for correct operation: After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet.
  • Page 5 Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENANCE. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: Replace or clean the inlet air grille as required.
  • Page 6 Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault.
  • Page 7: Troubleshooting

    3. Crimped or blocked tubing 3. Straighten, clear, or replace tubing Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com...
  • Page 8: Spare Parts List

    Drawing No. :- TPC161 Issue :- 2 Date :- 23/06/03 BD-150 SPARE PARTS LIST UMBER ESCRIPTION UMBER UANTITY Compressor (AK5512E) 3020116 Compressor Overheat Protector 3031728 Compressor Capacitor 3036337 Condenser Coil 3020727 Evaporator Coil 3020732 Filter Dryer 3020904 Fan Motor Assembly 3035774 By-pass Valve 3020810...
  • Page 9: Limited Warranty

    Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.