Page 1
User Manual X1222 Premium 16-Input 2/2-Bus Mixer with XENYX Mic Preamps & Compressors, British EQs, 24-Bit Multi-FX Processor and USB/Audio Interface...
4.2 Cable connections ............12 5. Specifications ............13 Thank you Congratulations! In purchasing the BEHRINGER XENYX you have acquired a mixer whose small size belies its incredible versatility and audio performance. The XENYX Series represents a milestone in the development of mixing console technology.
3. Heed all warnings. ARE SUBJECT TO CHANGE WITHOUT NOTICE AND 4. Follow all instructions. ACCURACY IS NOT GUARANTEED. BEHRINGER, 5. Do not use this apparatus near water. KLARK TEKNIK, MIDAS, BUGERA, AND TURBOSOUND ARE PART OF THE MUSIC GROUP (MUSIC-GROUP.COM).
Turn the MAIN MIX faders and the PHONES control in the main section fully down before The interface of BEHRINGER mixing consoles is optimized for these tasks, you switch on the unit. Always be careful to set the appropriate volume.
LINE IN Should your BEHRINGER product malfunction, our goal is to have it repaired as Each mono input also features a balanced line input on a ¼" connector. quickly as possible. To arrange for warranty service, please contact the retailer Unbalanced devices (mono jacks) can also be connected to these inputs.
XENYX X1222USB User Manual LOW CUT 2.1.3 Aux sends (MON and FX) The mono channels of the mixing consoles have a high-slope LOW CUT filter for eliminating unwanted, low-frequency signal components (80 Hz, 18 dB/octave). GAIN Use the GAIN control to adjust the input gain. This control should always be turned fully counter-clockwise whenever you connect or disconnect a signal Fig.
XENYX X1222USB User Manual All stereo channel strips have a GAIN control for level setting. In those channels in which a mic input is present in the channel, the GAIN control has two scales: The PAN control determines the position of the channel signal within the stereo just like in the mono channels, there is a 0 to +40 dB scale that shows the image.
Page 8
XENYX X1222USB User Manual MON SEND ◊ If the connected effects processor receives no input signal, the FX MUTE switch is probably pressed and/or the FX SEND control is too low. The aux send control MON SEND acts as master control for the monitor bus and This also goes for the built-in effects processor.
(e.g. DAT recorder) or also a CD player. They can also be used as stereo with a nominal level of +4 dBu. Depending on how you wish to use your mixer line input. Alternatively, the output signal of a second XENYX or BEHRINGER and which gear you own, you can connect the following equipment: ULTRALINK PRO MX882 can also be connected.
USB port on your computer. There are no required drivers, but we recommend that PC users install the included ASIO driver. The driver can also be downloaded from behringer.com. 2.4 Graphic 7-band equalizer Fig. 2.14: Level meter POWER The blue POWER LED indicates that the device is switched on.
XENYX X1222USB User Manual FBQ FEEDBACK DETECTION PHANTOM The switch turns on the FBQ Feedback Detection System. It uses the LEDs in the The PHANTOM switch activates the phantom power supply for the XLR frequency band faders to indicate the critical frequencies. On a per-need basis, microphone inputs, which is required to operate condenser microphones.
XENYX X1222USB User Manual FOOTSWITCH ¼" TS footswitch connector Connect a standard footswitch to the footswitch connector; use this to switch the strain relief clamp effects processor on and off. A flashing dot at the bottom of the display indicates sleeve if the effects processor is muted via the footswitch.
XENYX X1222USB User Manual 5. Specifications Balanced ¼" TRS connector strain relief clamp Mono Inputs sleeve ring Microphone Inputs (XENYX Mic Preamp) Type XLR, electronically balanced, discrete input circuitry Mic E.I.N. (20 Hz - 20 kHz) sleeve ground/shield @ 0 Ω source resistance -134 dB / 135.7 dB A-weighted ring @ 50 Ω...
Page 14
Max. output level +19 dBu / 150 Ω (+25 dBm) BEHRINGER is constantly striving to manintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to existing products without prior notice. Specifications and...
Page 15
XENYX X1222USB User Manual FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION XENYX X1222USB MUSIC Group Services US Inc. Responsible Party Name: 18912 North Creek Parkway, Address: Suite 200 Bothell, WA 98011, Phone: +1 425 672 0816 Phone/Fax No.: Fax: +1 425 673 7647 XENYX X1222USB complies with the FCC rules as mentioned in the following paragraph: This equipment has been tested and found to comply with the limits for a Class B...