Summary of Contents for Honeywell MK7580-30A38-00-A - MS7580 Genesis - Wired Barcode Scanner
Page 1
® MetroSelect Area Imaging Supplemental Configuration Guide...
Page 2
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Imager Operation † Presentation and Trigger Modes There are four configurable modes for scanning: the presentation mode, the multi-try trigger mode, the continuous trigger mode, and the single-trigger mode. These modes can be configured separately for in-stand and out-of-stand ‡ imager operation ‡...
‡ Out-of-Stand Presentation Mode * Multi-Try Trigger Mode Out-of-Stand Out-of-Stand ³ ³ Continuous Trigger Mode Single Trigger Mode Out-of-Stand Out-of-Stand ³ ³ In-Stand/Out-of-Stand Mode Match Set In-Stand Mode to Match Out-of-Stand Mode ³ Factory default configuration for the MS1690, MS1890, and the MS1633. ...
Page 7
* Presentation Mode † Immediately After Button Release ³ The imager immediately reverts to presentation mode when the button is released. Presentation Mode 1 second After Button Release ³ The imager reverts to presentation mode 1 second after the button is released.
Page 8
* Enable Disable Trigger Press Timeout Trigger Press Timeout In Presentation Mode In Presentation Mode ³ ³ Factory default configuration. ® This feature is only supported in the Focus product series (i.e., IS1650, MS1890, MS1633, and the MS1690).
Omnidirectional and/or Linear Imager Modes The area imager can be configured to operate as an omnidirectional imager, or a † linear imager, or a combination of both. Trigger and presentation operations can be configured separately for omnidirectional and linear scan modes. •...
Page 11
Enable 1D Linear Only Disable 1D Linear Only in Trigger Operations in Trigger Operations ³ ³ Enable Linear Only Disable Linear Only in Presentation Operations in Presentation Operations ³ ³ Enable 1D Linear Only Disable 1D Linear Only in Presentation Operations in Presentation Operations ³...
Aiming and Illumination Trigger and presentation operations can be configured separately to use the imager’s linear illumination as an aiming instrument. * Enable Aiming in Disable Aiming in Trigger Operations Trigger Operations ³ ³ * Enable Aiming in Disable Aiming in Presentation Operations Presentation Operations ³...
Page 13
* Enable Auto Gain Disable Auto Gain ³ ³ * Enable Illumination Disable Illumination Group 1 Group 1 ³ ³ * Enable Illumination Disable Illumination Group 2 Group 2 ³ ³ Factory default configuration. This feature is only supported in the Focus product series (i.e., IS1650, MS1890, MS1633, and the MS1690).
Character Suppression Enable the * Disable the Suppression of 1 Character Suppression of 1 Character ³ ³ To suppress 1 character: Scan the Enter/Exit Configuration Mode bar code, on page 39. Scan the Enable the Suppression of 1 Character bar code. Scan the Character 1 bar code (below left).
Same Symbol Timeouts Retain Same Symbol * Reset Same Symbol Timeout on Trigger Timeout on Trigger ³ ³ The same-symbol timeout The same-symbol timeout is is not restarted when the restarted when the trigger is trigger is pulled. pulled. LED Options * Normal Blue LED Intensity ...
Imager Operation – MS1633 †† Power Save Modes Enable * Disable Trigger Power-Save Trigger Power-Save ³ ³ When enabled, the MS1633 will enter sleep mode after the trigger is held for 10 seconds. Enable Disable IR Power-Save IR Power-Save ³ ³...
® †† RangeGate Mode Enable Disable RangeGate RangeGate ³ ³ When enabled, the MS1633 will store scanned bar codes into non-volatile memory if the wireless connection has been interrupted. Note: RangeGate and Inventory Mode are mutually exclusive. If both are enabled, Inventory Mode takes priority.
†† Firmware Version and Address Transmit the Firmware Version of the ® Imager with Bluetooth Wireless Technology ³ Transmit the Address of the Imager with Bluetooth Wireless Technology ³ †† These features are not for use with the MS1690, MS1890 or the IS1650.
†† Inventory Mode In Inventory mode, there is a quantity field associated with each bar code. When an item’s bar code is scanned, the MS1633 automatically stores the bar code data in its non-volatile memory with a quantity field set to 1. The quantity field can then be modified using the quantity bar codes on page 20.
Page 23
The quantity bar codes on page 20 enable the user to enter a quantity for the last item scanned. The item’s bar code data will be stored and transmitted as many times as the quantity indicates. If the Transmit Quantity Field feature (on page 18) has been enabled then the bar code data will be stored and transmitted once with a numerical quantity added to the end of the data string.
Page 24
†† Quantity Codes Quantity 0 Quantity 5 ³ ³ Quantity 1 Quantity 6 ³ ³ Quantity 2 Quantity 7 ³ ³ Quantity 3 Quantity 8 ³ ³ Quantity 4 Quantity 9 ³ ³ †† This feature is not for use with the MS1690, MS1890, or the IS1650.
Page 25
Transmit * Do Not †† Entry Counter Transmit Entry Counter ³ ³ Optional field transmitted with the bar code data that is a count of the number of transmissions used to transmit the entire buffer. Transmit †† Number of Records ³...
Page 26
†† Enable Inventory Beep * Disable Inventory Beep ³ ³ When enabled MS1633 will beep after transmitting each inventory record. †† Delete Last Record ³ When scanned, this bar code will delete the last bar code stored. †† Clear Inventory Records ³...
Code Types and Decode Rules Data Matrix Enable Normal Color Enable Inverse Color Data Matrix Decoding Data Matrix Decoding ³ ³ Enable Normal and Inverse * Disable Color Data Matrix Decoding Data Matrix Decoder ³ ³ Enable Rectangular * Disable Rectangular Data Matrix Symbol Data Matrix Symbol Decoding...
Page 28
Enable Low-Contrast * Disable Low-Contrast † Data Matrix Decoding Data Matrix Decoding ³ ³ † Improves decoding low-contrast Data Matrix symbols. Enable Data Matrix * Disable Data Matrix † Non-Square Modules Non-Square Modules ³ ³ † Improves decoding Data Matrix symbols when individual modules in the symbol are non- square.
Page 29
* Enable Data Matrix, Normal Size ³ The following bar codes improve decoding of Data Matrix symbols when the length of a symbol size is small. To disable either of these options scan the Enable Data Matrix Normal Size bar code above. Enable Data Matrix, Enable Data Matrix †...
QR Code Enable Normal Enable Inverse Video QR Code Video QR Code ³ ³ Enable Normal and Inverse QR Code * Disable QR Code ³ ³ MaxiCode Enable MaxiCode * Disable MaxiCode ³ ³ Factory default configuration.
Aztec Enable Normal * Disable Normal Video Aztec Decoding Video Aztec Decoding ³ ³ Enable Inverse * Disable Inverse Video Aztec Decoding Video Aztec Decoding ³ ³ Factory default configuration...
Page 32
Enable Aztec Structure * Disable Aztec Structure Append Decoding Append Decoding ³ ³ When this feature is enabled, Aztec bar codes with a structured append header will be stored in the imager’s memory buffer. The imager will transmit the concatenated message once every component of the structured append bar code has been read.
Postal Enable * Disable Australia Post Australia Post ³ ³ Enable Japan Post * Disable Japan Post ³ ³ Enable KIX Code * Disable KIX Code ³ ³ Factory default configuration.
Page 35
Enable * Disable UPU Decoding UPU Decoding ³ ³ Enable * Disable Royal Mail 4 Code Royal Mail 4 Code ³ ³ Enable * Disable Zero-FCC Australia Post Zero-FCC Australia Post ³ ³ Factory default configuration.
RS232 Software Handshaking Enable Disable ]V Handshaking ]V Handshaking ³ ³ An “]V” response from the host indicates reception of imager data. ® † Multifunctional USB/IBM Interface † Dual Interface Defaults ³ † This feature is not for use with the MS1633.
Interfaces † Additional Interfaces Enable Beeper * Disable Beeper ON/OFF Commands ON/OFF Commands ³ ³ Enables beeper on/off commands with internal USB and IBM interfaces. Generation IBM 46xx Defaults ³ First, scan the 3 Generation IBM 46xx Default bar code. Then, scan the IBM Reserved Code #2.
Page 40
IBM 46xx-SIOC RS485 Interface Send 30H for Last Block * Send 00 for Last Block Label Identifier 4680 Label Identifier 4680 ³ ³ Note: Feature is for PDF Note: Feature is for PDF codes only. codes only. IBM-OEM USB Interface Send 30H for Last Block * Send 00 for Last Block Label Identifier USB...
MS7580 Genesis Specific Load RS232 Load USB Configuration Settings Configuration Settings ³ ³ Load Keyboard Wedge Load RS485 Configuration Settings Configuration Settings ³ ³ Recall Configuration for Currently Connected Interface ³ This feature is only supported in the MS7580 Genesis.
Page 42
Apply Settings Apply Settings to to All Interfaces the Current Interface ³ ³ Apply Settings Apply Settings to RS232 Interface to USB Interface ³ ³ Apply Settings Apply Settings to Keyboard Wedge to RS485 Interface ...
Need help?
Do you have a question about the MK7580-30A38-00-A - MS7580 Genesis - Wired Barcode Scanner and is the answer not in the manual?
Questions and answers