Addressing; Programming; Vi. Programming - GE NX-1710E - Single Door Control Module Installation And Start-Up Manual

Single door control networx series
Table of Contents

Advertisement

V.

ADDRESSING

The first thing that must be decided is the address of this particular relay/output module. This is the address that
will be selected when programming the auxiliary devices. To set the addresses use the table below. Refer to
Table V-1 that follows for possible addresses.
The door control unit must be powered down and powered back up in order to read
new or modified dip switch settings.
Table V-1
Bus Address
1
128
129
ON
130
131
ON
132
133
ON
134
135
ON
VI.

PROGRAMMING

USING THE LED KEYPAD
E
P
NTERING THE
ROGRAM
[
Go To Program Code
Factory Default is
E
M
NTERING THE
ODULE
Scan a card.
(example only)
L
F
OADING THE
ACTORY
D
C
EFAULTING THE
NX-1710E Single Door Control
Dip Switch Setting
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
M
ODE
]
A
DDRESS
#
D
(
EFAULTS
USER PROGRAMMING ONLY
#
S
N
ARD
ERIAL
UMBERS
#
Bus Address
1
136
137
ON
138
139
ON
140
141
ON
142
143
ON
Enters the Program Mode.
Stay, Chime, Exit, Bypass & Cancel LEDS
will flash.
If the "Go To Program Code" is valid, the
"Service" LED will flash and the five function
LEDs will illuminate steady. You are now in the
Program Mode and ready to select the module
address.
Enter the module address. Refer to Table V-1
for the address.
The Armed LED will illuminate while it is
waiting for a programming location to be
entered.
)
The keypad will beep 3 times indicating that
the loading is in progress. The loading takes
about 6 seconds.
The keypad will beep 3 times indicating that
the loading is in progress.
Dip Switch Setting
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Networx nx-1710e

Table of Contents