System Messages
Table 3
System Error and Recovery Messages (continued)
LED Type
LED Color
AUX/
Green
PWR
—
—
—
—
AUX/
Amber
PWR
Troubleshooting Cisco 2800 Series Routers
10
Message, Meaning, and Recommended Action
Message:
%ENVMON-5-48V_STATUS: -48V supply OK
Explanation:
The –48 V power supply is operating normally.
Recommended action:
Message is informational only.
Message:
%ENVMON-5-RPS: Redundant power supply attached
Explanation:
Redundant power supply was connected to the router.
Recommended action:
Message is informational only.
The Cisco 2801 does not support RPS. This message is not applicable to the Cisco 2801.
Note
Message:
%ENVMON-5-RPS: Redundant power supply removed
Explanation:
Redundant power supply was disconnected from the router.
Recommended action:
Message is informational only.
The Cisco 2801 does not support RPS. This message is not applicable to the Cisco 2801.
Note
Message:
%ENVMON-5-RPS_STATUS: RPS standby/faulty
Explanation:
Redundant power supply has failed or has gone into standby mode.
Recommended action:
Check the redundant power supply. If faulty, disconnect it from the router and contact your
Cisco technical support representative.
Note
The Cisco 2801 does not support RPS. This message is not applicable to the Cisco 2801.
OL-5789-01