NetServer LXr Pro8 Outside Service Reference Label
NetServer LXr Pro8 Outside Service Reference Label
About This Label
Audience Assumptions
This Service Reference Label is for trained service personnel.
Hewlett-Packard Company assumes you are qualified in the
servicing of computer equipment and trained in recognizing
hazards in products with hazardous energy levels.
Electrostatic Discharge To avoid catastrophic or hidden
damage to components, wear a wrist strap and use a
static-dissipative work surface connected to the chassis
when handling components. Use an antistatic service kit,
such as 3M
8501/8502/8505 or equivalent.
®
This information is subject to change without notice and is provided
without warranty.
Copyright 1998, Hewlett-Packard Company. All rights reserved.
Support
HP NetServer Navigator CD:
CD is shipped with the system in the Navigator Kit.
The Information Assistant on the CD contains complete
documentation and will search, display, and print on a NetServer
system or any Windows PC.
®
A copy of this label can be printed from the Information Assistant
on a current Navigator CD. (To maintain safety compliance, do
not keep any paper inside the system cabinet.)
Subscriptions are available. See the Information Assistant or one
of the Electronic Support Services, below, for ordering.
HP NetServer Diagnostic Assistant:
Run from Navigator CD, or
Use flexible disk shipped with system in pouch in the satellite, or
Download from one of the Electronic Support Services, below.
Proactive E-Mail Notification:
Sign up at http://www.hp.com/go/netserver. Click on "Service
and Support"
Electronic Support Services:
Internet Web Page http://www.hp.com/go/netserver
Internet FTP ftp://ftp.hp.com/pub/servers
CompuServe Library GO HPPC
Support Questions:
HP-Authorized Reseller
CompuServe Discussion Forum GO HPPC
US / Canada Phone Support 1-970-635-1000 (Colorado)
Europe Phone Support (+31-20) 581-3330 (Netherlands)
HP has offices in over 100 countries. Check telephone directory.
Satellite Disassembly /
Reassembly
x 4
Specifications
Power Requirements
Voltage and frequency: 200-240VAC 16A single cord input at 47-63Hz
Power consumption: 970W typical usage max; 1560W design max
Maximum inrush current: 80A for 10ms
Power availability: 200W continuous to PCI cards and internal drives
Circuits: Delayed action circuit breaker recommended. Configurations
use one or two branch circuits per rack.
• North America
208/240V 60Hz - - NEMA AB1 class 14B 20A for each 16A PDU.
20 Amp branch circuits are recommended, using NEMA L6-20R
receptacles.
• Outside North America
220 / 230 / 240V 50/60Hz -- IEC Type D for 16A circuits for each
16A PDU. Minimum 16 Amp branch circuits are recommended.
Space Requirements
System dims: 17.5"H x 19.0"W x 32.1"D (44.5cm x 48.6cm x 81.5cm)
Rack space: 10 EIA units
Rack clearance: 46" (117cm) beyond rear of HP rack -- door mounted
30" (76cm) beyond rear of HP rack -- no door
System weight: 170lb (76kg)
Air Conditioning Requirements
Maximum heat output: 3300 BTU / hour
Operating temperature: 41 to 95 degrees F (5 to 35 degrees C)
Operating humidity: 20% to 80% RH noncondensing
Tested PCI Cards
Limitations apply to the use of PCI cards in this system. Refer
to the Configuration Advisor on HP NetServer Navigator CD.
Data Integrity and System
Reliability
The covers and panels are integral parts of the system and must
be in place to maintain data integrity under normal levels of
electromagnetic noise, static discharge, and vibration.
Even at low room temperatures, all covers and panels must
be in place to provide controlled airflow for system reliability.
Check that each Mass Storage Shelf has either a drive or a
filler panel -- whether or not the front door is in place.
Check that the rear panel, two fan packs, and the top cover are
in place -- whether the system is rack-mounted or being shipped.
Shipping the System
All covers and panels must be in place when the system is moved
or shipped.
The shipping package protects the system -- including properly
installed mass storage devices -- under normal shipping conditions.
Do not ship the system mounted in a rack.
Memory
6
Troubleshooting
Check that DIMMs are the correct HP product number. (See panel
8
of this label.) DIMMs supplied and warranted by HP have an
HP label. Repairs due to the use of non-HP DIMMs are not covered
5
under the warranty.
Size
DIMMs Inter-
leave
256MB
2
4
512MB
4
8
8
16
1GB
1.5GB
12
8
2GB
16
16
24
16
3GB
4
4GB
32
16
Size
DIMMs Inter-
leave
4
3
5GB
40
16
6GB
48
16
7GB
56
16
8GB
64
16
*
Refers to Optional Lower Memory Board
Control Panel
Troubleshooting
Check that the Satellite Retention Bracket is in place on
the center rear of the base chassis.
Run Indicator
Green during power up =
Power On Self-Test
has passed; system is starting to boot
Green during operation = BIOS is running
DC Ouput Indicator
Green = DC voltages from power supplies OK
Off = System in standby -- press power button.
Check CPU Power Switch on rear of
Docking Station
AC Input Indicator
Green = AC power input to system OK
Off = Check AC power to system
Attention Indicator
Off = Normal operation
Yellow =
Component failure -- refer to message
display on Control Panel
Flashing Yellow = Hardware Identification and
Labeling Utility is flashing the light to
identify this server
Notes:
Message display on control panel will display fatal errors
for one minute before system shuts down.
4-pin connector on rear of Control Panel Board is unused.
Power Supply Modules
Troubleshooting
Check the Satellite Power Interlock Switch on the left rear
of the base chassis.
DC Output Indicator
Green = DC output voltages from module OK
Off = Check CPU Power Switch on rear of
Docking Station
AC Input Indicator
Green = AC power input to module OK
Attention Indicator
Off = Normal operation
Yellow =
System is in standby mode or one or more
DC output voltages is out of specification
Notes:
Connector on front of each Power Supply Module is unused.
Reserved
31
Memory
DIMM Locations
Board
28
24
20
16
12
8
Upper
Upper
Upper
Upper
Upper
Upper
Upper
Memory
Board
28
24
20
16
12
8
Upper
Lower *
Upper
Lower *
Upper
Lower *
Upper
Lower *
Product and Part Numbers
For a list of all accessories, use the Information Assistant on a current
Navigator CD or download the HP NetServer Order Assistant from
www.hp.com/go/netserver. For rack configuration and installation
information, download the HP NetServer Rack Assistant.
Internal Accessories
D5030A
Processor Board, Dual 200 / 1MB (incl. CPUs)
D5026A
256MB Memory DIMM Kit (2 ea. 128MB DIMMs)
D5027A
Second Memory Board (32 DIMM sockets)
D5963A
Non-DAC Ultra SCSI Extender Drawer, 6-Channel
D5972A
DAC Cable Extender, 6-Cable
D5973A
Hot-Swap Kit -- Power Supply and Fan Packs
Internal Mass Storage
D4910A
4GB wide SCSI HDD with drive mounting tray
D4911A
9GB wide SCSI HDD with drive mounting tray
C1555A
DAT Tape, HP Model 24i (order D2199A tray)
Mounting Trays
D2199A
5 1/2" DAT / CD Tray (3-pack; no front panel)
D2198B
3 1/2" Non Hot-Swap Drive Tray (3-pack; incl. front panel)
I/O Cards
D4943A
NP NetRaid PCI DAC Card
D4983B
Cable Kit for 3rd connector of D4943A DAC
D5013A
HP DeskDirect 10/100TX PCI Server LAN Adapter
J2585B
HP DeskDirect 10/100VG PCI LAN Adapter
External Mass Storage
D3636C
SCSI Cable; Std. HD-68 to Std. HD-68, 2.5m
D3637C
SCSI Cable; Std. HD-68 to Ultra HD-68, 2.5m
D4902A
Rack Storage/8 Storage Enclosure
D3583C
4.2GB Hot-Swap Ultra SCSI Disk Module
D4903A
4.2GB 10,000rpm Hot-Swap Ultra SCSI Disk Module
D4289A
9.1GB Hot-Swap Ultra SCSI Disk Module
D5039A
18.2GB Hot-Swap Ultra SCSI Disk Module
Uninterruptable Power Supplies (order from APC Corp.)
NS3000RMT3U
208V UPS U.S. In: L6-20P, Out: 2 L6-20R and 1 L6-30R
NS3000RM
I
3U
230V UPS Europe In: C20, Out: 1 C19, 8 C13
Power Distribution Units (no power cord)
E7670A
10A PDU, 19"; In: C14, Out: 10 C13
E7671A
16A PDU, 19"; In: C20, Out: 6 C13 and 2 C19
E7672A
Kit: E7670A and E7671A PDUs plus E7742A Jumper Cord
E7666A
16A Dual-Input PDU, 56"; In: 2 C20, Out: 2 C19 and 12 C13
Power Cords
E7798A
Power Cord, 250 VAC (C20 to C19), 2.5m (std. with system)
E7804A
Power Cord, 250 VAC (C20 to C19), 4.0m
E7801A
Power Cord, 240 VAC (L6-20P to C19), 2.5m
E7803A
Power Cord, 250 VAC (L6-20P to C19), 4.5m
E7799A
Power Cord, 240 VAC (L6-30P to C19), 2.5m
E7805A
Power Cord, 240 VAC (L6-30P to C19), 4.5m
E7800A
Power Cord, 240 VAC (Unterminated to C19), 2.5m
E7806A
Power Cord, 240 VAC (Unterminated to C19), 4.5m
D4991A
Y Adapter Power Cord (C14 to 2 C13) (for 2 RS/8s in one rack)
E7742A
Jumper Power Cord, 2.5m (C14 to C13)
Rack Accessories
(Download HP NetServer Rack Assistant Software for details.
See Panel
on this label.)
0
D4984A
Rack Installation Kit with Extra Hardware and Install Docs
E7797A
Rack Mounting Hardware Kit (25 ea. 10-32 screws and nuts)
E7723A
Cable Guide, 24", pkg. of 2
4
0
D4984-60007
Cable Ties, Hook-and-Loop, 12", pkg. of 5
D4950B
HP NetServer Keyboard, Mini-DIN
C3751B
HP Mouse, Mini-DIN
J1493A
Console Switch 4 port
J1497A
Console Switch 8 port
J1462A
Switch / Server Cables, 7 ft, set of 3 for one server
J1463A
Switch / Server Cables, 12 ft, set of 3 for one server
4
0
002-52459, Label Version 2