Using Web Browser (continued)
Error information page
If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen, click
the part to display the details of the error.
Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
 When [FAILED] has appeared for an item
Parameter
FAN
INTAKE AIR TEMPERATURE
EXHAUST AIR TEMPERATURE
OPTICS MODULE TEMPERATURE
LAMP REMAIN TIME
LAMP STATUS
Network status page
Displays the current configuration information of the network.
Displays the configuration details of wired LAN.
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
Intake air temperature is high. It could be because it is used in an environment of high
temperature such as close to a heating device, etc., the air intake is blocked, or the air
filter is clogged.
Exhaust air temperature is high. Exhaust may be blocked, or [Fan control] mode may be
set wrong. See [Fan control] of the Projector Operations.
Optics module temperature is high.
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
OK:
Normal operation
FAILED:
Occurrence of trouble
WARNING: Abnormal condition
Description