Samsung AW07A0NEB Owner's Instructions Manual

Window-type room air conditioner

Advertisement

Acondicionador de aire doméstico sistema de tipo ventana
O ar Condicionado de Window-Type
Condizionatore d'aria per ambienti da finestra
DB98-04664A(6)
E S F P I
OWNER'S INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL D'UTILISATION
MANUAL DE INSTRUÇÕES
ISTRUZIONI PER L'USO
A W07F0(1)(3)NAA/AB/BA/BB/BC/CA/DA/DB/EA/EB/EC
AW08F0(1)(3)NAA/AB/AC/AD
AW09F0(1)(3)NAA/BA/CA/DA/EA/EB
AW10F0(1)(3)DAA/BA/CA
AW12F0(1)(3)DAA/BA/CA/DA/EA/EB/EC
AW14F0(1)(3)MAA/AB/BA/CA/DA/EA
AW18F0(1)(3)MBA/BB/BC/BD/DA/EA/EB
AW18F0(1)(3)MCA/CB/CC
AWT18F0(1)(3)MBA/BB/DA/EA/EB
AW22F0(1)(3)MBA/CA/DA/EA
AW22F0(1)(3)MBB/CB/DB/EB
AW24F0(1)(3)MBA/CA/CB/CC/CD/DA/EA
AW24F0(1)(3)MBB/BC/BD/EB
AWT24F0(1)(3)MBA/CA/DA/EA
AWT24F0(1)(3)MBB/BC/EB/EC
Window-type Room Air Conditioner
Climatiseur de type Fenêtre
A W07A(G)0(1)(3)NAA/AB/BA/BB/BC/CA/DA/DB/EA/EB/EC
AW08A(G)0(1)(3)NAA/AB/AC/AD
AW09A(G)0(1)(3)NAA/BA/CA/DA/EA/EB
AW10A(G)0(1)(3)DAA/BA/CA
AW12A(G)0(1)(3)DAA/BA/CA/DA/EA/EB/EC
AW14A(G)0(1)(3)MAA/AB/BA/CA/DA/EA
AW18A(G)0(1)(3)MBA/BB/BC/BD/DA/EA/EB
AW18A(G)0(1)(3)MCA/CB/CC
AWT18A(G)0(1)(3)MBA/BB/DA/EA/EB
AW22A(G)0(1)(3)MBA/CA/DA/EA
AW22A(G)0(1)(3)MBB/CB/DB/EB
AW24A(G)0(1)(3)MBA/CA/CB/CC/CD/DA/EA
AW24A(G)0(1)(3)MBB/BC/BD/EB
AWT24A(G)0(1)(3)MBA/CA/DA/EA
AWT24A(G)0(1)(3)MBB/BC/EB/EC
(Cool)
(Refrigeración)
(Refroidissement)
(Refrigeração)
(Raffreddamento)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AW07A0NEB

  • Page 1 OWNER’S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D’UTILISATION MANUAL DE INSTRUÇÕES ISTRUZIONI PER L’USO A W07F0(1)(3)NAA/AB/BA/BB/BC/CA/DA/DB/EA/EB/EC A W07A(G)0(1)(3)NAA/AB/BA/BB/BC/CA/DA/DB/EA/EB/EC AW08F0(1)(3)NAA/AB/AC/AD AW08A(G)0(1)(3)NAA/AB/AC/AD AW09F0(1)(3)NAA/BA/CA/DA/EA/EB AW09A(G)0(1)(3)NAA/BA/CA/DA/EA/EB AW10F0(1)(3)DAA/BA/CA AW10A(G)0(1)(3)DAA/BA/CA AW12F0(1)(3)DAA/BA/CA/DA/EA/EB/EC AW12A(G)0(1)(3)DAA/BA/CA/DA/EA/EB/EC AW14F0(1)(3)MAA/AB/BA/CA/DA/EA AW14A(G)0(1)(3)MAA/AB/BA/CA/DA/EA AW18F0(1)(3)MBA/BB/BC/BD/DA/EA/EB AW18A(G)0(1)(3)MBA/BB/BC/BD/DA/EA/EB AW18F0(1)(3)MCA/CB/CC AW18A(G)0(1)(3)MCA/CB/CC AWT18F0(1)(3)MBA/BB/DA/EA/EB AWT18A(G)0(1)(3)MBA/BB/DA/EA/EB AW22F0(1)(3)MBA/CA/DA/EA AW22A(G)0(1)(3)MBA/CA/DA/EA AW22F0(1)(3)MBB/CB/DB/EB AW22A(G)0(1)(3)MBB/CB/DB/EB AW24F0(1)(3)MBA/CA/CB/CC/CD/DA/EA AW24A(G)0(1)(3)MBA/CA/CB/CC/CD/DA/EA AW24F0(1)(3)MBB/BC/BD/EB AW24A(G)0(1)(3)MBB/BC/BD/EB AWT24F0(1)(3)MBA/CA/DA/EA AWT24A(G)0(1)(3)MBA/CA/DA/EA...
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when installing and using your air conditioner. The air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring, earthing and safety regulations. Depending on national regulations and your specific installation, you may need to install: ◆...
  • Page 3: Table Of Contents

    Contents ◆ REPARING ONDITIONER Safety Precautions ..................■ Air Conditioning Unit - Main Parts and Control Panel ........■ ◆ PERATING ONDITIONER Cooling Your Room ..................■ Airing Your Room ................... ■ Switching the Air Conditioner Off ..............■ Adjusting the Air Flow Direction Horizontally ..........■...
  • Page 4: Air Conditioning Unit - Main Parts And Control Panel

    Air Conditioning Unit - Main Parts and Control Panel ❄ The design and shape are subject to change according to the model. Air outlet Inner air flow blades (right/left orientation) Air inlet (Inside) Outer air flow blades (up/down orientation) Air filter (The air filter is Air inlet (Outside) located in inside.)
  • Page 5: Cooling Your Room

    Cooling Your Room You must select the Cool mode if you wish to lower the temperature in your room. You can also set the fan speed. Select the operating mode and fan speed. To cool your room with a... Set the operating mode selection dial to...
  • Page 6: Airing Your Room

    Airing Your Room If the atmosphere in your room is stale, you can air it using the Fan feature and if necessary, evacuate the stale air outside. If you wish to evacuate stale air outside, push the ventilation lever on the front of the unit to the right and the open position ( Result: The air inside the room circulates and stale air is evacuated outside.
  • Page 7: Adjusting The Air Flow Direction Horizontally

    Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room, you can adjust the orientation of the inner air flow blades on the right-hand side of the unit, thus increasing the efficiency of the air conditioner. ✦...
  • Page 8: Selecting Energy Saving Mode (Only ✴✴✴✴F3/A3/G3✴✴✴ Models)

    (Only ✴✴✴✴F3/A3/G3✴✴✴ models) Selecting Energy Saving Mode If you wish to save energy when using the air conditioner, select the energy saving mode by using the Energy Saver switch. This feature is normally used when the room is unoccupied. To select the energy saving mode, set the Energy Saver switch to the ON position.
  • Page 9: Cleaning Your Air Conditioner

    Cleaning Your Air Conditioner (✴✴✴✴F0/F1/F3✴✴✴ models) Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period of time. When cleaning the air conditioner, turn it off and pull out IMPORTANT the power plug.
  • Page 10 Cleaning Your Air Conditioner (✴✴✴✴A0/A1/A3/G0/G1/G3✴✴✴ models) To get the best possible use out of your air conditioner, you must clean it regularly by two weeks to remove the dust on the air filter. ☛ Before cleaning your air conditioner, ensure that it is switched off and unplugged from the wall socket.
  • Page 11: Solving Common Problems

    Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. PROBLEM EXPLANATION / SOLUTION ◆ Check that the circuit breaker used for the air conditioner The air conditioner does not has not been triggered.
  • Page 12: Technical Specifications

    Technical Specifications Design and specifications are subject to change without notice. Model Power Supply ✴✴✴✴✴✴✴AA/AB/AC/AD 115V~, 60Hz ✴✴✴✴✴✴✴BA/BB/BC/BD 220V~, 60Hz ✴✴✴✴✴✴✴CA/CB/CC/CD 230-208V~, 60Hz ✴✴✴✴✴✴✴DA/DB 200-220V~, 50Hz ✴✴✴✴✴✴✴EA/EB/EC 220-240V~, 50Hz...
  • Page 13: Installation

    Installation (for 60Hz) Electrical Requirements For personal safety: ◆ This appliance must be properly grounded. ◆ Do not, under any circumstances, cut or remove the third grounding prong from the power cord. ◆ We recommend that you do not use an extension cord or an adapter plug with this appliance.
  • Page 14 Installation Before installation, be sure to check the installation area for the air conditioner, and drain hose. Checkpoints prior to installation Check the cabinet and front grille of the unit for any harmful defects such as scratches. Be sure to check the power supply. - Refer to the specifications on the label attached to the unit.
  • Page 15 Installation of the Drain Tube Rear Fix the drain tube as shown in the figure. Rubber cap Gasket Drain Tube Screws(2EA) Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area. ◆...
  • Page 16 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUÉ PAR: ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR: QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA: Printed in Korea...

This manual is also suitable for:

Aw07a1nabAw07a1nebAw07a1neb/xefAw07f0nabAw07f0nebAw07f0nec ... Show all

Table of Contents