Chamberlain Elite SL3000UL Owner's Manual

Chamberlain Elite SL3000UL Owner's Manual

Vehicular slide gate operator
Hide thumbs Also See for Elite SL3000UL:

Advertisement

O W N E R ' S M A N U A L
S L 3 0 0 0 U L ™
V E H I C U L A R S L I D E G A T E O P E R A T O R
THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY
AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
INTENDED FOR PROFESSIONAL INSTALLATION ONLY.
UL325
UL991
compliant
compliant

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elite SL3000UL and is the answer not in the manual?

Questions and answers

Summary of Contents for Chamberlain Elite SL3000UL

  • Page 1 V E H I C U L A R S L I D E G A T E O P E R A T O R THE SL3000UL™ IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
  • Page 3: Table Of Contents

    WARNING WARNING T A b l E O f c O N T E N T s sPEcIfIcATIONs ANd wARNINgs WARNING WARNING Overview and Specifications ......2 Mechanical Model Classification .
  • Page 4: Specifications And Warnings

    3 0 0 0 u l ™ M O d E l s O V E R V I E w s i n g l e M o t o r M o d e l s SL3000UL™ (Single Motor) 1/2 HP Motor, 120Vac, 4 Amp.
  • Page 5: Model Classification

    3 2 5 M O d E l c l A s s I f I c A T I O N s the SL3000UL™ is intended for use in vehicular slide gate applications: Class I – Residential vehicular gate operator A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
  • Page 6: Safety Installation Information

    s A f E T y I N s T A l l A T I O N I N f O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 7: Gate Construction Information

    g A T E c O N s T R u c T I O N I N f O R M A T I O N Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org.
  • Page 8: Safety Precautions

    WARNING s A f E T y P R E c A u T I O N s ThE sl3000ul™ Is fOR usE ON VEhIculAR PAssAgE gATEs ONly ANd NOT INTENdEd fOR usE ON PEdEsTRIAN PAssAgE gATEs. WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 9: Suggested Safety Protection Device Locations

    WARNING s u g g E s T E d s A f E T y P R O T E c T I O N d E V I c E l O c A T I O N s WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 10: Suggested Safety Protection Device Locations

    WARNING s u g g E s T E d s A f E T y P R O T E c T I O N d E V I c E l O c A T I O N s WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 11: Installation

    Installation I N s T A l l A T I O N s E T u P s f r o n t o r R e a r P o s i t i o n w i t h s i n g l e O p e r a t o r UL approved catch roller with safety cover.
  • Page 12: Safety Catch Rollers And Gate Rail Stops

    s A f E T y c A T c h R O l l E R s A N d g A T E R A I l s T O P s safety catch Rollers dO NOT use a gate catch Post.
  • Page 13: Mounting Operator

    M O u N T I N g O P E R A T O R top inside View Conduit area without battery back-up. 8.25" 4 Concrete Anchors 13" 1/2" x 3 1/2" High voltage above conduit. 6" Ground 10" Low voltage conduit.
  • Page 14: Chain Installation Types

    WARNING c h A I N I N s T A l l A T I O N T y P E s Front Operator position Drawings not to scale Weld rear WARNING bracket with gate To reduce the risk of SERIOUS INJURY or DEATH, make sure in closed exposed idler pulleys have safety covers on them.
  • Page 15: Control Board Description

    c O N T R O l b O A R d d E s c R I P T I O N 1 HP Board Plug-In Loop Detectors CENTER SAFETY EXIT Maglock/Solenoid Relay Module Connection UL Alarm Connection Surge Suppressor Master/Second Connection DC-BACKUP SYSTEM ON...
  • Page 16: Surge Suppressor Terminal Connections

    Master/Second Connection s u R g E s u P P R E s s O R T E R M I N A l c O N N E c T I O N s Output power Ground 24Vdc 120Vac Power Removable...
  • Page 17: Earth Ground Rod Installation

    Wiring WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you Install an optional reversing edge BEFORE proceeding operator MUST NOT be performed until disconnecting the with the control station installation.
  • Page 18: 120Vac Power Connection

    1 2 0 V a c P O w E R c O N N E c T I O N On-Off switch for operator. Black 120Vac WARNING White Neutral Green Ground Green Ground Use a 20 amp dedicated circuit for each operator. Input power 120Vac, 60 Hz.
  • Page 19: Linking Master/Second Operators

    l I N k I N g M A s T E R / s E c O N d O P E R A T O R s Use a 20 amp dedicated power circuit for each operator. Never run high voltage and low voltage wires in same conduit. Run low voltage 16-18 gauge wire in UL approved conduit to link operators together.
  • Page 20: Solenoid/Maglock Connection

    #8 Normally Open (Blue) Ground s O l E N O I d / M A g l O c k R E l A y c O N N E c T I O N Connection of a solenoid or magnetic lock can be made using the J7 board connector and “Optional” Relay Adapter Module. See Accessories.
  • Page 21: Factory Installed Dc2000™ Connection

    f A c T O R y I N s T A l l E d d c 2 0 0 0 ™ c O N N E c T I O N d c 2 0 0 0 ™ s t a r t u p Plug in the 12 pin plug into the DC2000™...
  • Page 22 d c 2 0 0 0 ™ d E V I c E w I R I N g M a n u a l l y O p e r a t e d d c 2 0 0 0 ™ d e v i c e s Manual external devices should be dry-contact which do not consume any current like push buttons or a key switch.
  • Page 23: Plug-In Loop Detector Wiring

    P l u g - I N l O O P d E T E c T O R w I R I N g WARNING plug-in Loop Detectors See Accessories CENTER SAFETY EXIT WARNING POWER ON DETECT LOOP FAIL FREQUENCY SENSITIVITY BOOST...
  • Page 24: 120Vac External Loop Detector Wiring

    1 2 0 V a c E X T E R N A l l O O P d E T E c T O R w I R I N g ® – – Class 2 Class 2 Supply Supply center center...
  • Page 25: Entrapment Protection Devices (Contact Sensors)

    WARNING E N T R A P M E N T P R O T E c T I O N d E V I c E s contact sensors (Edge sensor) WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: •...
  • Page 26: Entrapment Protection Devices (Non-Contact Sensors)

    E N T R A P M E N T P R O T E c T I O N d E V I c E s Non-contact sensors (12Vdc Photoelectric sensors) NOTE: Property owners are obligated to test photoelectric sensors monthly. entrapment non-contact Sensor Outside Property Entrapment Danger...
  • Page 27: Omni Option Board Connections (Optional)

    O M N I O P T I O N b O A R d c O N N E c T I O N s Purchased separately from Chamberlain Elite. See Accessories. NOTE: Refer to the Omni Option Board manual for more specific information.
  • Page 28: Adjustments

    WARNING Adjustments WARNING To reduce the risk of SERIOUS INJURY or DEATH: Disconnect electric power BEFORE performing ANY adjustments. s E T g A T E O P E N I N g d I R E c T I O N WARNING CAUTION ENGLISH...
  • Page 29: 315 Mhz 24Vdc Radio Receiver Programming

    WARNING 3 1 5 M h Z 2 4 V d c R A d I O R E c E I V E R P R O g R A M M I N g setting security Mode (high) or (Normal): WARNING WARNING The receiver is factory set at HiGH security mode.
  • Page 30: Mhz 24Vdc Radio Receiver Programming

    3 1 5 M h Z 2 4 V d c R A d I O R E c E I V E R P R O g R A M M I N g nOtice: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver IMPORTANT: Hand-held remote NOT included.
  • Page 31: Setting The Timer (On, Off)

    s E T T I N g T I M E R ( O N , O f f ) DC-BACKUP SYSTEM ON TIMER s i n g l e O p e r a t o r MS LINK POWER SENSORS OVERLOAD...
  • Page 32: Adjusting Reversing Sensor(S)

    A d j u s T I N g R E V E R s I N g s E N s O R ( s ) Adjust the “reverse Sensor” on the control board. alarm Sensor does not need to be adjusted except where noted below. the level of reverse sensitivity depends on the weight of the gate and the condition of installation.
  • Page 33: Maintenance And Operation

    Maintenance and Operation IMPORTANT SAfETY INSTRUCTIONS WARNING to reduce the risk of SeVere inJUrY or DeatH: 1. READ AND FOLLOW ALL INSTRUCTIONS. 5. Use the emergency release ONLY when the gate is not moving. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children.
  • Page 34: Built-In Reset Switch

    b u I l T - I N R E s E T s w I T c h When the gate operator’s audio alarm has been tripped (see below), the reset switch must be pushed for the operator to function again. The reset switch will shut off an activated audio alarm and reset the operator to function again.
  • Page 35: Emergency Manual Release

    E M E R g E N c y M A N u A l R E l E A s E T u r n t h e p o w e r O f f ! NOTE: Use the dedicated breaker switch to disconnect power to the operator.
  • Page 36: Accessories

    Accessories Brackets 4 inch 5 inch 6 inch V-Groove power 12Vdc external Wheels Series Loop Detectors plug-in Loop Dc2000™ Kit 4 inch 5 inch 6 inch Detectors Part # magnetic Lock (Outdoor) Part # Part # AELD ODC2000SL Part # MG1300 remote controls...
  • Page 37: Wiring Diagrams

    w i r i n g d i a g r a m • S L 3 0 0 0 u L ™ electronic power Strip White Wires Black Wires Chassis Ground Omnicontrol™ Board CENTER SAFETY EXIT motor relay adapter module (Optional) 1234567...
  • Page 38 w i r i n g t a b L e • S L 3 0 0 0 u L ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection Safety Loop 5 or 0Vdc External Loop Input Power Neutral Detector Wires, Not Used...
  • Page 39 w i r i n g d i a g r a m • S L 3 0 0 0 u L d m ™ electronic power Strip White Wires Black Wires Chassis Ground Omnicontrol™ Board motor motor CENTER SAFETY EXIT relay adapter...
  • Page 40 w i r i n g t a b L e • S L 3 0 0 0 u L d m ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection Safety Loop 5 or 0Vdc External Loop Input Power Neutral Detector Wires,...
  • Page 41 w i r i n g d i a g r a m • S L 3 0 0 0 u L 1 H P ™ Electronic Power Strip White Wires Black Wires Chassis Ground 1 HP Board OmniControl™ Board Green Motor Black...
  • Page 42 w i r i n g t a b L e • S L 3 0 0 0 u L 1 H P ™ OmniControl™ Board J Pin # Signal Type Direction Level (+/- 10%) Input Connection 5 or 0Vdc Safety Loop External Loop Detector Input Power Neutral...
  • Page 43 w i r i n g d i a g r a m • d c 2 0 0 0 ™ f o r S i n g L e a n d d m NOTE: This diagram only shows the DC2000™...
  • Page 44 w i r i n g t a b L e • d c 2 0 0 0 ™ NOTE: All devices wired to the DC2000™ MUST be dedicated to it alone. Normal operation will be controlled by separate devices wired to the OmniControl™...
  • Page 45: Troubleshooting

    Troubleshooting The gate will Not Operate with Remote: OPEN LEFT OPEN RIGHT RADIO STRIKE GATE OPEN LEFT OPEN RIGHT OPEN RECEIVER LOCKED RADIO CENTER STRIKE GATE LOOP OPEN RECEIVER LOCKED The radio receiver LED on the control board remains “Off” when using the remote control. CENTER LOOP The radio receiver LED on the...
  • Page 46 T R O u b l E s h O O T I N g c O N T I N u E d Condition Probable Causes Solution 1. Short circuit at terminals 11 and 13. 1. Remove the short circuit condition at the Overload LeD On 2.
  • Page 47: Repair Parts

    Repair Parts R E P A I R P A R T I l l u s T R A T I O N s SL DM *Q029 ODC2000SL Q033 Q254 Q024 Q028 K75-50932 312HM DM / 1 HP Q039 K75-50893 Q027 Q030...
  • Page 48: How To Order Repair Parts

    h o W t o o r d e r r e p a i r p a r t s OUR LARGE SERVICE ORGANIZATION SPANS AMERICA. INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-2806 www.chamberlain.com WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:...
  • Page 49: Installation Checklist

    Installation Checklist 1. Owner and Installer must read all warnings and safety precautions. 2. Make sure concrete mounting pad is big enough and deep enough for operator. 3. Operator must be securely fastened to concrete pad. 4. Operator chain must be 4 inch minimum from gate. Chain must not be too tight or too loose. 5.
  • Page 50: Warranty Policy

    7 year residential/ 5 year commercial from the date of purchase [and that the SL3000UL™ is free from defect in materials and/or workmanship for a period of 7 year residential/ 5 year commercial from the date of purchase].
  • Page 52 S L 3 0 0 0 U L ™ UL325 UL991 compliant compliant 845 Larch Avenue Elmhurst, Illinois 60126-1196 01-50388G © 2009, The Chamberlain Group, Inc. – All Rights Reserved...

Table of Contents

Save PDF