OP2 = Aux Relay
OP3 = OP3
OP4 = OP2
IP1 = Aux Input
IP2 = Door Contact
Important !
IP3 = Push Button
Always Place Varistor
Across Lock Terminals
+12V
Power
Supply Unit
0V
Note:
If the Mains Present or Door
Contact inputs are not used,
they should be linked to 0V
This illustration shows wiring
for a normally energised
lock. If a normally de-energised
lock is required, use the
N/O relay contacts.
DS100e Door Station Installation
Door
Contact
OP3 OP4 0V IP1 IP2 IP3
NC
C
NO
NC
C
5A 250VAC
NO
5A 30VDC
TAMPER
MAINS
PRESENT
+
12V DC
-
4 5 6 7 8
On
To set the door number,
set address switches
4-8 as shown
LED Functionality:
Red LED indicates the status of communications with the Controller.
While online to the controller the Red LED will flash rapidly.
If there is a problem it will flash slowly (about once a second).
Green LED will flash if an event occurs on the DS100e.
Door
Release
Network cable is single
shielded twisted pair,
Button
Belden 9501 or similar
To next door
SERIAL NETWORK
DTR RX TX 0V B
1 2 3 4 5 6 7 8
On
N
ADDRESS
Entry/Exit Reader
5
4
5
6
8
4
6
7
10 OFF ON
OFF ON
03 OFF OFF OFF ON
ON
11 OFF ON
OFF ON
04 OFF OFF ON
OFF OFF
12 OFF ON
ON
05 OFF OFF ON
OFF ON
06 OFF OFF ON
ON
OFF
13 OFF ON
ON
07 OFF OFF ON
ON
ON
14 OFF ON
ON
15 OFF ON
ON
08 OFF ON
OFF OFF OFF
16 ON
OFF OFF OFF OFF
09 OFF ON
OFF OFF ON
www.accesscontrol.ie
ACT 2000
NETWORK
A
B
0V
Shield
Total Length max 1.4km
A
Wiring for Clock and Data / Wiegand Reader
Max len 30M
Cable: 8 Core Screened
7
8
Belden 9504 or equiv
OFF
ON
OFF OFF
OFF ON
FACTORY DEFAULT
ON
OFF
This unit should be reset to its
ON
ON
factory default condition before
installation. To do this, power
the unit up with ALL switches in
the OFF position. The two LED's
will illuminate for about 2 sec.
The correct switch settings may
then be set.
A
B
DTR
White
SENSE
Green
CLOCK / DATA 1
Blue
DATA / DATA 0
Red
+5v
Black
0v
Brown
RED
Yellow
GREEN
Orange
(Buzzer Ctrl)
For Clock & Data
Readers, wire exit
reader in parallel
but leave it's
sense line
unconnected.
For Wiegand
Readers, wire the
DATA 0 of the exit
reader to SENSE
on the DS100e
18-00037
Need help?
Do you have a question about the DS100E DOOR STATION and is the answer not in the manual?
Questions and answers