Canon VB-M700F Operation Manual page 129

Network camera vb-m700f/vb-m600d/vb-m600ve operation guide
Hide thumbs Also See for VB-M700F:
Table of Contents

Advertisement

S412 Timer service initialization error [crit]
Description
timer initialization error [%1] [%2] (S412)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of the timer service.
Countermeasure If the problem persists after rebooting, the camera is faulty. Arrange for servicing.
S413 Timer service runtime error [crit]
Description
timer working error [%1] (S413)
%1
Error number
Meaning
An error occurred while the timer service was running.
Countermeasure If the problem persists after rebooting, the camera is faulty. Arrange for servicing.
S501 Fan stop detected [alert]
Description
FAN rotation speed is less than 150rpm. (S501)
Meaning
The camera's internal fan has stopped or RPM has dropped significantly.
Countermeasure Camera needs to be serviced.
S502 Temperature fuse disconnect detected [alert]
Description
Heater unit error. Fuse is cut off. (S502)
Meaning
The temperature fuse on the heater substrate was disconnected.
Countermeasure Camera needs to be serviced.
VB-M600VE
VB-M600VE
List of Log Messages
8
8
-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb-m600dVb-m600ve

Table of Contents