Accessing the MUX Main Control Menu Programming/Controlling MUX Functions 4.2.1 Password Entry 4.2.2 MUX Main Control Menu Command Descriptions MUX Error Messages IntuiKey Menu Reference Camera Control Command Reference Keyboard Camera Commands Bosch Security Systems, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 4
| Table of Contents IntuiKey Keyboard F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security Systems, Inc.
The display reverts to Normal Mode either automatically in two seconds (on its own) or when CLR is pressed. In Terminal Mode, the third-party software application determines the displayed text via the IntuiKey display screen. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
This initial menu contains softkey functions that represent commonly used commands, as well as keys that represent links to other command menus. In Terminal Mode, the third-party software application determines the displayed text via the IntuiKey display screen. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
DVR 2 DVR 9 Unit B Unit H DVR 3 DVR 10 Unit C Unit J DVR 4 DVR 11 Unit D Unit K Figure 1.3 Main Product Selection Menu F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
If an existing softkey screen number is assigned to a new softkey screen, the old one is no longer valid. Assignments remain even if power is lost. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
ALERT added. The present product is displayed for two seconds, while the alarmed product is displayed for 0.5 seconds. NOTICE! This functionality is not supported when the IntuiKey is operating in Terminal Mode. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Monitor Camera 1234 Allegiant Figure 2.1 Status Display in Four-digit Allegiant Mode Monitor Camera 1234 Allegiant Figure 2.2 Status Display in Six-digit Allegiant Mode Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
The Allegiant Main Control menu, displayed on the softkey display, uses the softkey buttons to execute commands or to gain access to other submenus for additional programming/ configuration. Detailed command descriptions follow. Refer to the Allegiant Switcher Instruction Book for additional information. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 13
If the camera is locked, the display shows an RL in the monitor’s on-screen status display, indicating that the remote device is locked. If the camera is unlocked, RL is removed. To exit the Device Lockout menu press EXIT. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 14
MA (Monitor Armed). – Disarm Monitor Pressing the Disarm Monitor softkey disarms the monitor currently controlled by the keyboard, thus prohibiting the monitor from responding to alarms. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 15
– Delete from Here to End Deletes all remaining steps after the step presently displayed on the OSD. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 16
USER LOG ON, and the status display changes back to the default mode (i.e. camera and monitor numbers replaced with dashes). This mode times out in approximately two seconds and reverts to the previous menu. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 17
NOTE: The Command Script menu can be customized with specific scripts and submenus using the optional IntuiKey PC software package. Refer to the documentation included with the software for more specific instructions. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 18
If an attempt to use a User Function results in an error message, please consult your Allegiant system manual to determine if the function is supported in your particular model. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Allegiant User Function # Access Level Menu 20 Display User #/Priority Menu 20 Change User Password Menu 20 Show Keyboard Port # Menu 20 Keyboard Audio Menu 20 Display Battery Status Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 20
Cache Remote Cameras Menu 24 Auto Phase Adjustment Notes: When using LTC 8900 systems, the access levels required are 1 to 63. Password is required to change this setting. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
A request was made to load a RELATIVE type sequence on a monitor number that is too high; the monitors used by the sequence would extend past the highest monitor. Try switching to a lower monitor number before loading the sequence. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 22
Error 96 * (STAR) Undefined The * key has been pressed, but there is no definition for this button. Error 128 No Communications The keyboard cannot communicate with the Allegiant. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Controlling Divar Series Digital Video Recorders | en Controlling Divar Series Digital Video Recorders This section applies to the KBD-Universal and KBD-Digital models. NOTE: Depending on the model of the Divar, some features described below may not be supported. See the table below for supported software features by Divar model.
SEQ – Indicates that the DVR is running a sequence. – MON A/B – Indicates which DVR monitor is currently under control. It toggles between MON A and MON B for each press of the MON key. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
NOTE: For the Divar MR, PTZ control is only available when in full screen mode. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 26
Places the DVR into the on-screen search mode and accesses a DVR softscreen menu allowing selection of various search criteria. Refer to Section 5.2.2 for details on menu functions and controls. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 27
Accesses the DVR Control menu allowing selection of DVR devices and controls for navigation of device on-screen menus. Refer to Section 3.2.3 DVR Control Menu, Page 25, for details on menu functions. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Help screen, or to exit the on- screen menu completely without saving. Restores defaults in the active on-screen menu. Select Selects an on-screen menu or submenu item and saves selections made in menus. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
User Level as listed on the softkey menu. NOTICE! The selected User Level applies to all DVR devices connected to the IntuiKey. – Help Accesses the DVR’s on-screen Help menu. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Invalid Keyboard Entry An invalid number has been entered on the keyboard. Error 3 Invalid DVR Number A DVR number less than 1 or greater than 30 was entered. Error 4 DVR Not Found No DVRs found during search. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
IntuiKey Keyboard Controlling System4 Video Multiplexers | en Controlling System4 Video Multiplexers This section applies to KBD-Universal and KBD-Digital Models. Accessing the MUX Main Control Menu Press PROD to put the keyboard in the Product Selection Mode. The softkey display shows the Product Selection menu.
– 6-channel: 5+1 – 9-channel: 4+3, 3x3 – 16-channel: 4+3, 8+2, 12+1, 3x3, and 4x4 NOTICE! Pressing the multiscreen softkey multiple times cycles through the possible selections. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 33
Freeze a different camera image by selecting another camera with the camera keys and pressing FREEZE again. Changing the display screen mode releases the freeze mode from all cameos. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 34
Refer to Appendix B at the back of this manual for details on the Camera Commands. MUX Control Accesses a menu allowing control of additional multiplexer functions. Exit On-screen Quick Menu Keys Find Select MUXes User Level Audio Figure 4.5 MUX Control Submenu F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 35
MUX main control menu (approximately two (2) seconds or after pressing CLR). Refer to the Multiplexer Instruction Book for additional information on the quick key functions. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
An invalid button has been pressed on the keyboard. Error 3 Invalid Multiplexer Number A multiplexer number less than 1 or greater than 30 was entered. Error 4 Multiplexer Not Found No multiplexers were found during search. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Right > Disable Increase Pause Speed v Down Down v Play Decrease Choose: Save: Forward Speed SELECT SELECT – – – Play Select Reverse Escape Figure A.1 Keyboard Menu Structure Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 38
Cameras Verbosity Printer Address Port Mode Mode Select Cache Remote Crosspnt. Cameras Data Auto Phase Interface Adjustment <Previous Next> <Menu Menu> < > Figure A.2 Keyboard Menu Structure, continued F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 39
Aux 4 Dither Aux 6 Conventional Receiver/Driver Misc. Camera Commands Commands Exit Fast Fast Address Address Display Fast Address Unassigned Aux On Aux Off Figure A.3 Keyboard Menu Structure, continued Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 40
| IntuiKey Keyboard F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
(located next to the joystick) for more than two seconds. – Modify Preset Tour This command is specific to G3 AutoDome® cameras. Pressing this softkey displays a camera on-screen display. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 42
– Advanced Menu Press this softkey to enter the main on-screen programming menu of G3 and Day/Night Series AutoDomes having firmware of 2.0 or higher. F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 43
See the individual device control section for details of the Camera Functions menu. NOTICE! If ENTER is held down, the Aux command auto-repeats until the key is released. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 44
| IntuiKey Keyboard F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Re-initialize Camera Functions on 72 R/D Specific Commands Auto/Random Pan on/off 1 Random/Auto Pan on/off 7 Aux 2 on/off 2 Aux 3 on/off 3 Aux 4 on/off 4 Dither on/off 5 Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 46
55 Note 3 Fast Address Display on 997 Note 3 Fast Address All on 998 Note 3 Fast Address Unassigned on 999 Note 3 Alarm Status on 64 F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.
Page 47
Feature applicable only to G3 cameras having firmware equal to or greater than version 2.00 Feature applicable only to G3 cameras having firmware less than version 2.00. Feature applicable only to G3 cameras having firmware greater than version 2.00. Bosch Security System, Inc. User Manual F.01U.127.291 | 1.93 | 2009.03...
Page 48
| IntuiKey Keyboard F.01U.127.291 | 1.93 | 2009.03 User Manual Bosch Security System, Inc.