55 Watt Electric Airless Spray Gun OPERATING INSTRUCTIONS Thank you for purchasing the Earlex ASG55 Spray Gun, this is a highly versatile spray gun and can be used for a variety of applications. BEFORE USE - PLEASE READ THE SAFETY &...
Store idle tools - When not in use, tools should be Use only genuine Earlex replacement parts. stored in a dry, high or locked place, out of reach of children.
Page 3
The ASG55 is a highly versatile electric airless spray paint container on your ASG55, gun, it can be used with several different spray the paint is filtered through mediums including, varnishes, wood treatments, either a funnel with a filter on it, enamel paint, oil and water based paints.
(Fig.5A). ASG55 from the mains and firmly push the suction 2. Let your arm control the left to right movement tube into the tapered hole of the raised boss. Fill the...
HELPFUL HINTS ENSURE ADEQUATE VENTILATION AND DO NOT 1. Evenly control the speed of movement of the spray SPRAY NEAR NAKED FLAMES. gun. A fast speed will give a thin coat and a slow G Remove the top knob, slightly push the nozzle speed will give a heavy coat.
TROUBLE SHOOTING PROBLEM CAUSE ACTION REQUIRED Spray Gun HUMS Piston sticking. Remove the large knob at the top of the unit part no. but does not part no. SG237 SG266. Pull nozzle and piston assembly down and operate back to release from main gun assembly. Unscrew and remove nozzle.
SG242 1.0 Litre Paint Container OPTIONAL ACCESSORIES All of the parts below can be purchased seperately from Earlex, please phone our Helpline No 01483 454666. Flexible Extension Tube (Decking Nozzle) The flexible extension tube can be bent at an angle to make the painting of ceilings and floors much easier.
PLEASE NOTE We have done all we can to ensure that used correctly and according to these instructions, the Earlex ASG55 Electric Airless Spray Gun will give long trouble free service. We accept no responsibility for damage caused by the use of incorrect or unsuitable substances, paint or fluids which have not been thinned correctly or are unsuitable for the surfaces to which they are applied, health hazards arising from lack of ventilation when working in confined spaces, or failure of the equipment due to inadequate cleaning of components after use.
Need help?
Do you have a question about the ASG55 and is the answer not in the manual?
Questions and answers