Movincool Office Pro 60 Operation Manual

Movincool Office Pro 60 Operation Manual

Denso movincool portable air conditioner operation manual pro 60
Hide thumbs Also See for Office Pro 60:

Advertisement

OPERATION
MANUAL
OFFICE PRO 60
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Office Pro 60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Movincool Office Pro 60

  • Page 1: Operation Manual

    OPERATION MANUAL OFFICE PRO 60 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS. SECCIÓN EN ESPAÑOL SECTION EN FRANÇAIS...
  • Page 2 © 2003 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO SALES CALIFORNIA, INC. reserves the right to make changes without prior notice. MovinCool is a registerd trademark of...
  • Page 3 OPERATION MANUAL OFFICE PRO 60...
  • Page 5: Table Of Contents

    Cleaning the Air Filters ... 17 FIlter Removal Method ... 17 Cleaning Method ... 18 In-Season/Off-Season Inspection & Maintenance ... 18 TROUBLESHOOTING ... 19 Office Pro 60 Self-Diagnostic Codes ... 19 TECHNICAL SPECIFICATIONS ... 20 SECCIÓN EN ESPAÑOL ... 21 SECTION EN FRANÇAIS ... 45...
  • Page 7: Foreword

    Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to assemble, install and operate the MovinCool Office Pro 60 portable air conditioning unit. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also find it useful to keep this operation manual on hand for reference.
  • Page 8: General Warnings & Cautions

    UL approved ground-fault breaker to prevent electrical shock from the unit. • The Office Pro 60 is equipped with a six (6) foot (1.8 meter) power cord. If replacement, fixed location (hard wired) or power cord lengthening (extension cord) cords are required, contact your reseller or a qualified electrician for approved replacement methods.
  • Page 9: Inventory

    After unpacking your MovinCool unit, please check to make sure you have the following items: • Office Pro 60 MovinCool Unit (1) • Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
  • Page 10: Installation

    LOCKED position. • Install the unit in areas that can withstand the weight of the unit. The Office Pro 60 weighs approximately 625 lbs (281 kg). • Allow 24 inches (610 mm) of unobstructed airflow for both air inlets and outlets.
  • Page 11: Moving The Unit

    INSTALLATION (cont.) Moving the Unit Unlock the casters and push the MovinCool unit, using the side handles, to a flat, level surface and set the casters back to the LOCKED position. FRONT AND BACK HANDLES UNLOCKED LOCKED...
  • Page 12: Plugging In The Unit

    Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign matter. • The Office Pro 60 model is equipped with an approved NEMA plug configuration (S42). The appropriate outlet must be used for this plug type.
  • Page 13: Features

    FEATURES OP60 Features • An electronic control panel which allows the user to control the unit’s operation easily. • Dual fan speeds (either High or Low) in both COOL and Fan Only modes. • A digital display that indicates the Temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate.
  • Page 14: Operation

    FULL SET POINT ROOM TEMP SET TEMP CLOCK/TIMER FAN ON/OFF COOL ON/OFF Office Pro 60 Activates/deactivates the COOL mode/ turns the unit off. Activates/deactivates the HIGH or LOW fan mode. Increases/decreases the temperature set point. Flashes when the drain tank is full.
  • Page 15 CLOCK/TIMER START TIME END TIME SET CLOCK PROGRAM Office Pro 60 Illuminates to indicate the current temperatures being displayed are either in °C or °F; also used to display the clock when programming. Illuminates to indicate AM or PM time of day.
  • Page 16: Operating In Cool Mode

    OPERATION (cont.) Operating in COOL Mode ➀ The unit can be operated in COOL mode by pressing the COOL ON/OFF button (LED illuminates). NOTE: In COOL mode the unit can only be turned off by pressing the “COOL ON/OFF” button again, not by pressing the fan buttons. ➁...
  • Page 17: How To Set A Program

    OPERATION (cont.) How to Set a Program ➀ Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. ➁ Setting an END TIME Press the Program SET button until the END TIME LED illuminates.
  • Page 18 OPERATION (cont.) How to Set a Program (Cont.) NOTE: • The unit will return to the previous mode if a program is turned off while it is running. • The Program RUN LED flashes while a program is running. It is illuminated continuously when the program mode is activated.
  • Page 19: Operating Modes

    OPERATION (cont.) Operating Modes Office Pro 60 operates in 2 modes, FAN Only and COOL. When in FAN Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. •...
  • Page 20: Emptying The Drain Tank (If Equipped)

    OPERATION (cont.) Emptying the Drain Tank (If equipped) During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off.
  • Page 21: Drain Pump

    OPERATION (cont.) Drain Pump A drain pump is included to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water.
  • Page 22: Hose Installation

    HOSE INSTALLATION Note: The OP60 is equipped with a 20 foot (6 m) hose. Connect the 20 foot (6 m) hose to the drain outlet spout and feed it through the grommet on the right hand side of the unit. Note: Do not use more than 18 feet (5.5 m) of drain hose vertically.
  • Page 23: Daily Inspection & Maintenance

    Program RUN button. ➁ Remove the 2 air filters. NOTE: To remove the filters from the Office Pro 60, open the front panel and side panel filter doors. On the side panel door, carefully ...
  • Page 24: Cleaning Method

    DAILY INSPECTION & MAINTENANCE (cont.) Cleaning Method ➀ Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash with a neutral detergent. ➁ After the element has been cleaned, rinse with clean running water, allow to dry, then reinstall.
  • Page 25: Troubleshooting

    TROUBLESHOOTING Office Pro 60 Self-Diagnostic Codes Self-Diagnostic Codes will be displayed on the Control Board under the following conditions: TANK FULL SET POINT ROOM TEMP SET TEMP CLOCK/TIMER FAN ON/OFF START TIME END TIME SET CLOCK COOL ON/OFF PROGRAM Office Pro 60 Check the following points before calling a qualified technician.
  • Page 26: Technical Specifications

    W x D x H (mm) weight (lbs/kg) Operating Conditions inlet air (relative humidity) Control Device temperature control programmable timer two speed fan OFFICE PRO 60 95º F (35º C) 83º F (28.2º C) 60Hz single phase 208/230V 7.1 Kw 33 Amps 140A...
  • Page 27: Limited Warranty

    The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of any kind.
  • Page 28 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com Technical Services Department DSCA P/N: LA990009-1219 Third Issue: March 2003 GAC P/N: LA484007-1441 Printed in the U.S.A.

Table of Contents

Save PDF