Replacing The Thermocouple; External Inspection & Cleaning Of The Flame Arrestor; Cleaning The Combustion Chamber And Flame Arrestor - Kenmore 33125 - Power Miser 12 Owner's Manual

Ultra low nox gas water heater, for potable water heating only, not suitable for space heating, not for use in mobile homes
Table of Contents

Advertisement

Replacing
the Thermocouple
1.
Remove
the Burner
DoorAssembly
as directed
previously.
2.
Remove
the retainer
clip from the back of the two piece
wire connector
and remove
the two piece wire connector
from the assembly
(Figure
27).
3.
Pull the thermocouple
from the pilot assembly
(Figure
31 ).
IMPORTANT:
Be careful
not to bend
or alter the position
of the
pilot assembly
components.
4.
Push the new thermocouple
through
the holes in the
pilot bracket.
Insert the thermocouple
tube
into the holes
provided
in the pilot assembly
until it clicks
into place.
Leave
a small
straight
section
entering
and leaving
the
two piece wire connector
section
for easier
removal/
service.
5.
Position
the new thermocouple
through
the opening
of
the two piece wire connector
(Figure
27). NOTE:
The pilot
tube should
be located
at the top followed
by the igniter
wire then the thermocouple.
6.
See "Replacing
the Burner
DoorAssembly"
section.
PILOT
IGNITER
THERMOCOUPLE
TUBE
WIRE
TWO PIECE
WIRE CONNECTOR
DOOR
FIGURE
27.
Cleaning
the Pilot Assembly
1,
Follow the procedure outlined in "Removing the
Burner Door Assembly".
2,
Use a soft bristle brush to remove any debris that
may have collected on the pilot. Note: Clean any
debris found in the air slots at the base of the pilot.
See Figure 28,
3,
Follow the steps in "Replacing the Burner Door
Assembly" section to reassemble.
PILOT
b
IGNITER_
External
Inspection
& Cleaning
of the
Flame Arrestor
Although
not likely to occur,
if debris
collects
on the flame
arrestor,
use a vacuum,
compressed
air, or a soft bristle brush
to remove
it. NOTE:
If unable
to inspect
or clean the flame
arrestor
from underneath,
follow
the "Cleaning
the Combustion
Chamber
and Flame Arrestor"
section
instructions.
Flashligh L
Mirror
\
FIGURE
29
Cleaning
the Combustion
Chamber
and
Flame Arrestor
1.
2.
3.
Follow
procedure
outlined
in "Removing
the Burner
Door
Assembly"
section.
Use a vacuum
cleaner/shop
vac to remove
all loose
debris
in the combustion
chamber
(Figure
30). Use
compressed
air to clear any dust or debris
that may have
accumulated
in the flame arrestor.
Reassemble
following
the procedure
under the "Replacing
the Burner
Door
Assembly"
section.
FIGURE
28.
22

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 33125 - Power Miser 12 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Power miser 12153.331242153.331252

Table of Contents