Download Print this page
urmet domus 1088 Quick Manual
urmet domus 1088 Quick Manual

urmet domus 1088 Quick Manual

Ipassan controllers 2-smart, 2-smart ul certification, wiegand
Hide thumbs Also See for 1088:

Advertisement

Quick Links

DS1088-030
Link to complete controller manuals and IPassan
Manager software for online or local
configuration of the IPassan system
Link to video tutorials for programming and
configuration of the Ipassan system – EN -
Links zu den vollständigen Controller-
Handbüchern.
Enlaces a los manuales completos del
controlador.
Links naar de volledige controllerhandleidingen.
Links til de komplette controllermanualer.
IPASSAN CONTROLLERS
2-Smart 1088/4 - 1088/5
2-Smart UL certification 1088/14
Wiegand 1088/6 - 1088/7
QUICK GUIDE
1088/4
1088/5
1088/4
1088/5
Mod.
1088
LBT21530
1088/6
1088/7
1088/6
1088/7

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1088 and is the answer not in the manual?

Questions and answers

Summary of Contents for urmet domus 1088

  • Page 1 Mod. 1088 DS1088-030 LBT21530 IPASSAN CONTROLLERS 2-Smart 1088/4 - 1088/5 2-Smart UL certification 1088/14 Wiegand 1088/6 - 1088/7 QUICK GUIDE Link to complete controller manuals and IPassan Manager software for online or local configuration of the IPassan system 1088/4 1088/5...
  • Page 2 CONTENTS INTRODUCTION ....................2 Features ........................2 Hardware ........................ 2 INSTALLATION ....................4 Controllers ....................... 5 MEANING OF LEDS ON CONTROLLER ............10 Summary tables ....................10 FIRST START-UP ..................... 11 IPassan Manager ....................11 WARNINGS ....................... 11 INTRODUCTION IPassan is a full solution to manage door and lift access control, door phone system, CCTV and is also open to extra features such as intruder alarm, access counting, etc...
  • Page 3 2-Smart 24/48V - PoE 1088/6. Wiegand 12 V 1088/7. Wiegand 24/48V - PoE 1088/14 (UL) 2-Smart 12 V 1.2.2 Features • UL certification • 2 RS485 bus • RS485 bus MAIN between controllers • RS485 bus AUX between control and expansions •...
  • Page 4 1.2.4 Accessories Various types of optional devices were designed to increase the capacity and features of the system: DESCRIPTION POWER SUPPLY FUNCTIONS 1088/451 12-24Vac/Vdc With line end management 10-input module Clean contact (C-NO-NC 1088/452 12-24Vac/Vdc 10-output module...
  • Page 5 The expansion cards can be connected on the base (controller or expanders), and do not need extra power supply. Two screws are supplied to fasten the expansion card, while the cover is also supplied with four screws to fasten it CONTROLLERS The controllers can communicate via TCP/IP or RS485.
  • Page 6 Installation rules: - The RS485 bus is sensitive to disturbance and requires a specific twisted and shielded cable (FTP). - A and B signals must be connected on the same pair in the cable. - The controllers include a JUMPER (close to the RS485 terminal) which is an end of line resistor. Insert this jumper only on each side of the bus.
  • Page 7 2.1.5 TCP/IP The system allows you to have up to 64 controllers on each TCP/IP network. This means the 64 controllers can communicate with one another (APB zone or counting, for example). If the system requires more than 64 controllers, a second network has to be created in the software.
  • Page 8 WIEGAND READER WIRING Wiegand device Reader RF receiver Keypad etc. Note, the green led of the controller is ON while the relay is activated. The red led flashes once when the controller receives data from the Wiegand reader. The green led of the reader is activated for the door delay when a valid credential is used. The red led of the reader flashes quickly (3 times per second) when the credential is not authorised.
  • Page 9 2.1.7 Lock diagrams (standard and magnetic hold) STANDARD LOCK 12VCA TRANSFORMER Entrance hall button 12Vac lock MAGNETIC HOLD LOCK 12VDC Entrance hall button TRANSFORMER 2.1.8 REX button When a fail-safe lock is used, a second security must be used. Basically, with a 2-contact emergency button, the NO contact is connected to REX+/-, the NO contact is in series with the electric lock.
  • Page 10 2.1.9 Open door signal The IPassan system manages the door status (open/closed). The door contact can be balanced with line end resistors. In this case, the value of resistors R1 and R2 is settable via software. For default setting: Door R1 = 4,7KΩ...
  • Page 11 Controller status: Green led Fixed on The controller is powered Green led The controller is not powered After the initialisation phase, it indicates the Red led Flashing each second controller is working correctly Red led Fixed on or off Restart the controller Communication with the server: Green led Fixed on...
  • Page 12 • In the event of infiltration of liquids or objects inside the device and for possible repair, you are recommended to contact the technical support centre indicated by the manufacturer. • Do not use extension cords for the mains cable. •...

This manual is also suitable for:

1088/61088/71088/41088/51088/14