Download Print this page
Dover Hillphoenix QCD-26-R Installation & Operation Manual
Dover Hillphoenix QCD-26-R Installation & Operation Manual

Dover Hillphoenix QCD-26-R Installation & Operation Manual

Multi-deck merchandiser

Advertisement

Quick Links

MULTI-DECK MERCHANDISER
INSTALLATION & OPERATIONS MANUAL
QCD-26-R/QCD-32-R/QCD-37-R
BEVERAGE/DAIRY/DELI/PRODUCE/
Technical References ...................................... 2-13
General Information .............................................14
Installation ..................................................... 15-16
Case Connections ................................................ 17
Lighting & Power Supplies ............................. 18-19
To ensure proper functionality and optimum performance, it is STRONGLY recommended that Hillphoenix specialty cases be installed/serviced by qualifi ed tech-
nicians who have experience working with commercial refrigerated display merchandisers and storage cabinets. For a list of Hillphoenix-authorized installation/
service contractors, please visit our website at www.hillphoenix.com.
MEAT/SEAFOOD
Table of Contents
Pre-Power Checklist ............................................20
Airfl ow & Defrost ..................................................21
Case Cleaning ................................................ 22-23
Parts Ordering ......................................................24
Appendices
03/22

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hillphoenix QCD-26-R and is the answer not in the manual?

Questions and answers

Summary of Contents for Dover Hillphoenix QCD-26-R

  • Page 1 MULTI-DECK MERCHANDISER INSTALLATION & OPERATIONS MANUAL QCD-26-R/QCD-32-R/QCD-37-R BEVERAGE/DAIRY/DELI/PRODUCE/ MEAT/SEAFOOD Table of Contents Pre-Power Checklist ..........20 Technical References ........2-13 Airfl ow & Defrost ..........21 General Information ..........14 Case Cleaning ..........22-23 Installation ............. 15-16 Case Connections ..........17 Parts Ordering ............24 Lighting &...
  • Page 3 LIABILITY NOTICE For Cases with Shelf Lighting Systems Hillphoenix does NOT design any of its shelf lighting systems or any of its display cases with shelf lighting systems for direct or indirect exposure to water or other liquids. The use of a misting system or water hose on a display case with a shelf lighting system, resulting in the direct or indirect exposure of the lighting system to water, can lead to a number of serious issues (including, without limitation, electrical failures, fi...
  • Page 4 Important ® t Hillphoenix , the safety of our customers and employees, as well as the ongo- ing performance of our products, are top priorities. To that end, we include impor- tant warning messages in all Hillphoenix installation and operations handbooks, accompanied by an alert symbol paired with the word "DANGER", "WARNING", or "CAUTION".
  • Page 5 Revision History • new manual format_03/22...
  • Page 6 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-26-R 4', 5', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GENERAL NOTES: • "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. SHIPPING WEIGHT Case Weight...
  • Page 7 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-26-R 4', 5', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) ELECTRICAL DATA 120 Volts High Efficiency Anti-Condensate Fans Data Vista Frames Unheated Doors Fans Infinity 60 Case Length Case Amps Watts Amps Watts 0.43 0.18 0.43 0.32...
  • Page 8 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-26-R 4', 5', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GUIDELINES AND CONTROL SETTINGS (DX) {NSF TYPE 2 80F/55%RH} {DIRECT EXPANSION HFC/CO2} BTUH/ft Superheat Discharge Air Case Case Case Set Point @ Bulb Evaporator Discharge Air Velocity Application...
  • Page 9 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-26-R 4', 5', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) 25 11/16" [65.3 cm] FRONT SWINGING DOORS W/ VERTICAL LED LIGHTS 12" 12" 12" 12" 13 3/8" [33.9 cm] 25" [63.5 cm] ELECTRICAL BOX 25 11/16"...
  • Page 10 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-32-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GENERAL NOTES: • "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. SHIPPING WEIGHT Case Weight...
  • Page 11 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-32-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) ELECTRICAL DATA 120 Volts High Efficiency Fans Anti-Condensate Data Vista Frames Unheated Doors Fans Infinity 60 Case Length Case Amps Watts Amps Watts 0.43 0.18 0.43 0.35 0.87...
  • Page 12 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QC-32-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GUIDELINES AND CONTROL SETTINGS (DX) {NSF TYPE 2 80F/55%RH} {DIRECT EXPANSION HFC/CO2} BTUH/ft Superheat Discharge Air Case Case Case Set Point @ Bulb Evaporator Discharge Air Velocity Application Depth...
  • Page 13 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-32-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) 31 1/2" [80.1 cm] FRONT SWINGING DOORS W/ VERTICAL LED LIGHTS 16" 16" 16" 16" 19 3/8" [49.2 cm] 31" [78.8 cm] ELECTRICAL BOX 31 11/16" [80.5 cm] 12"...
  • Page 14 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-37-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GENERAL NOTES: • "---" Indicates that the feature is not an option on this case model and/or the data is not yet available at this time. SHIPPING WEIGHT Case Weight...
  • Page 15 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-37-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) ELECTRICAL DATA 120 Volts High Efficiency Anti-Condensate Fans Data Vista Frames Unheated Doors Fans Infinity 60 Case Length Case Amps Watts Amps Watts 0.43 0.18 0.43 0.35 0.82...
  • Page 16 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QC-37-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) GUIDELINES AND CONTROL SETTINGS (DX) {NSF TYPE 2 80F/55%RH} {DIRECT EXPANSION HFC/CO2} BTUH/ft Superheat Discharge Air Case Case Case Set Point @ Bulb Evaporator Discharge Air Velocity Application Depth...
  • Page 17 TECHNICAL REFERENCE Self-Service Multi-Deck In-Line Air Screen Merchandiser QCD-37-R 4', 6', 8' & 12' (Beverage/Dairy/Deli/Produce/Meat/Seafood) 36 11/16" [93.2 cm] FRONT SWINGING DOORS W/ VERTICAL LED LIGHTS 21" 21" 21" 21" 24 3/8" [61.9 cm] 36" [91.4 cm] ELECTRICAL BOX 36 11/16" [93.2 cm] 12"...
  • Page 18 GENERAL INFORMATION hank you for choosing Hillphoenix for your food merchandising needs. This handbook contains important technical infor- mation and will assist you with the installation and operation of your new Hillphoenix specialty cases. By closely following the instructions, you can expect peak performance; attractive fit and finish; and long case life. We are always interested in your suggestions for improvements (e.g.
  • Page 19 CASE INSTALLATION LOCATION ports as this will help ensure that the case is not settling over time. This refrigerated display case has been designed for displaying 7. Locate horizontal support positions along the chalk line and storing perishable food product. It is engineered for air- (Fig.
  • Page 20 CASE INSTALLATION of the case (under cross support), and lower the horizontal support on to the shim packs. Repeat on the other end of the case. ▲ W A R N I N G Be certain that your hands and feet are out of the way before lowering the case.
  • Page 21 CASE CONNECTIONS REFRIGERATION Before operating the case, be certain to remove the styrofoam shipping block that protects the plumbing lines during ship- ping. Refrigeration connections will be made through the refrigera- tion stub up location on the customer left side of the case. Refrigeration lines may be headed together for all cases in a ▲...
  • Page 22 LIGHTING & POWER SUPPLIES GENERAL LIGHTING INFORMATION ply need to be removed and/or replaced, turn off the power to the case before proceeding. Be certain to replace the power supply with genuine Hillphoenix parts or a comparable UL- Hillphoenix cases are equipped with LED luminaires. LED power supplies operate the vertical mullion lighting.
  • Page 23 LIGHTING & POWER SUPPLIES 12. Mount the fi xture using 8 x 5/8 Philips screw. Note: No additional holes are needed in the mullion. Pre-existing holes from the existing Optimax installation can be used on the new fi xtures. 13. Test the lights by turning on the light switch to make sure the connections are secure.
  • Page 24 PRE-POWER CHECKLIST Before powering-up the case, be certain that all of the steps listed below have been completed to ensure proper case functionality, safety and compliance with warranty terms. Have you thoroughly examined the case for shipping damage? (see pg. 14) Have you checked the vertical plumb of the case? The horizontal level? (see pg.
  • Page 25 AIRFLOW & DEFROST AIRFLOW & PRODUCT LOAD DETERMINING SUPERHEAT Hillphoenix cases provide maximum product capacity within the To identify proper superheat settings, complete the following: refrigerated air envelope. Please keep products within the ap- propriate load limit. 1. Obtain suction pressure from access port; obtain suction line temperature from area near TXV bulb at the outlet of It is important that you do not overload the food product display evaporator coil.
  • Page 26 CASE CLEANING CASE CLEANING ed lift handles (Fig. 10). There are hinges shared between the pressure plate and coil covers. Note: It is recommend- ed that more than one person lift the pressure plate. A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency, and The topside of pressure plate will rest against the topside of the coil cover, exposing the underside of the pressure...
  • Page 27 CASE CLEANING 3. Carefully, without bending the sheet metal cover, with the ▲ W A R N I N G use of the handles provided, gently slide the coil cover with the pressure plate assembly forward to expose the Exercise extreme caution when working in a case evaporator coil.
  • Page 28 PARTS ORDERING Contact the Service Parts Department at: 1-844-HPX-PART (1-844-479-7278) dfr-ia-parts@doverfoodretail.com Provide the following information about the part you are ordering: • Model number and serial number* of the case for which the part is intended. • Length of the part (if applicable). •...
  • Page 29 APPENDIX A1 ....................Wiring Information B1-B3 ................Dixell Operating Instructions C1 ..............Sporlan Pressure-Temperature Chart D1-D3 ......................Parts List...
  • Page 30 A1: WIRING DIAGRAM...
  • Page 31 B1: DIXELL OPERATING INSTRUCTIONS dIXEL Operating Manual 1592020130 DIGITAL CONTROLLER 6. FRONT PANEL COMMANDS XR03CX – XR04CX To display target set point, in programming mode it selects a parameter confirm operation 1. CONTENTS To start a manual defrost Contents __________________________________________________________________________ 1 General warnings ___________________________________________________________________ 1 programming mode...
  • Page 32 B2: DIXELL OPERATING INSTRUCTIONS dIXEL Operating Manual 1592020130 Hy Differential: (0,1°C 25°C) Intervention differential for set point. Compressor Cut IN is SET as the external digital input is disabled again. With the door open, the high and low temperature alarms are disabled.
  • Page 33 B3: DIXELL OPERATING INSTRUCTIONS dIXEL Operating Manual 1592020130 Protection: IP20; Frontal protection: IP65 Start defrost delay 0 ÷ 99 min. Connections: Screw terminal block 2,5 mm wiring. Display during defrost rt – in – SP – dF Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%; 230Vac 10%, 50/60Hz, 110Vac 10%, 50/60Hz Drip time 0 ÷...
  • Page 34 C1: SPORLAN PRESSURE-TEMPERATURE CHART...
  • Page 35 D1: PARTS LIST (QCD-26-R) Air Discharge Case Top Hinged Self-Service Doors Die Board Front Toekick Air Return Product Stop Insulated Drain Pan End Panel Trim End Panel End Toekick Outside Back Bottom Deck Price Tag Molding Adjustable Shelf Bracket Shelf Standard Plex Product Stop Inside Back...
  • Page 36 D2: PARTS LIST (QCD-32-R) Air Discharge Case Top Hinged Self-Service Doors Die Board Front Toekick Air Return Product Stop Insulated Drain Pan End Panel Trim End Panel End Toekick Outside Back Bottom Deck Price Tag Molding Adjustable Shelf Bracket Shelf Standard Plex Product Stop Inside Back...
  • Page 37 D3: PARTS LIST (QCD-37-R) Air Discharge Case Top Hinged Self-Service Doors Die Board Front Toekick Air Return Product Stop Insulated Drain Pan End Panel Trim End Panel End Toekick Outside Back Bottom Deck Inside Back Shelf Standard Adjustable Shelf Bracket Plex Product Stop Price Tag Molding...
  • Page 38 Hill PHOENIX, Inc. Hereinafter Referred To As Manufacturer LIMITED WARRANTY GENERAL WARRANTY Manufacturer’s products are warranted to be free from defects in materials and workmanship under normal use and maintenance for fourteen months from date of shipment from manufacturer (the “Base Warranty Period”). In the event of a qualifying warranty claim, a new or rebuilt part to replace any defective part will be provided without charge.
  • Page 39 Warning Maintenance & Case Care When cleaning cases the following must be performed PRIOR to cleaning: To avoid electrical shock, be sure all electric power is turned off before cleaning. In some installations, more than one switch may have to be turned off to completely de-energize the case.

This manual is also suitable for:

Hillphoenix qcd-32-rHillphoenix qcd-37-r