Intended Use

Intended purpose
This cuff is intended to be used for a digital monitor that measures blood pressure and pulse rate of adult patients.

Intended patients
Adult patient population

Intended users
Legally certified medical experts, such as doctor, nurse.

Limitation
Patient's arm circumference must be:

  • HEM-CS19-PD: 17-22 cm
  • HEM-CR19-PD: 22-32 cm
  • HEM-CL19-PD: 32-42 cm

Type of use
This cuff is intended to be multiple patient multiple use.
The clinical features below can be obtained if this cuff is used with specified OMRON blood pressure monitor.

  • Clinical benefit
  • Indication
  • Contraindications
  • Side effects

Clinical benefit
Patient's blood pressure can be measured non-invasively.

Indication
The device is used for healthy individuals and patients with hypertension related diseases in medical professional environments such as clinics, hospitals and physicians' office.

Contraindications

  • DO NOT use this cuff on:
    • An injured upper arm
    • An upper arm under medical treatment
    • An upper arm on which intravenous drip or a blood transfusion is being performed
    • An upper arm on which an SpO2 sensor, IBP catheter, or other instrument is attached
    • An upper arm with a shunt for hemodialysis
  • DO NOT apply the arm cuff on your arm while on an intravenous drip or blood transfusion.
  • DO NOT use the device on infants, toddlers, children or persons who cannot express themselves.
  • Do not attach the cuff to a patient under the use of a pump oxygenator.
  • Do not inflate the cuff without attaching it to an arm.

Side effects

  • Taking measurements more often than necessary may cause bruising due to blood flow interference.
  • Inflating to a higher pressure than necessary may result in bruising of the arm where the cuff is applied.
  • Stop using the device if the patient experiences skin irritation or discomfort.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Do not connect the air tube or cuff to the tubing of other devices connected to the body.
  • Do not use at extremely high temperature, high humidity, or high altitude. Use only within the required ambient conditions.
  • Properly connect the connectors
  • Do not spray, pour, or spill liquids into or onto the cuff.
  • If a cuff is used on some patients with an infection, treat the cuff as medical waste. Otherwise, an infection may result.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient, or cause damage to the equipment or other property.
  • Do not use thinner, benzene, or other solvents to wipe the cuff.
  • Do not sterilize by autoclave or gas sterilization (EOG, formaldehyde gas, high-concentration ozone, etc.).
  • Use the appropriate cuff size to ensure correct measurements.
  • Do not use the cuff if it is damaged or has holes.

How to Apply the Arm Cuff

  1. Select a cuff appropriate for the patient.
Arm circumference Size of the arm cuff
17 - 22 cm Small size adult arm cuff
22 - 32 cm Medium size adult arm cuff
32 - 42 cm Large size adult arm cuff
  • Use a suitable cuff size. Otherwise, incorrect measurement may result.
  1. Insert the air plug securely into the air connector of your monitor.
    How to Apply the Arm Cuff - Step 1
    • Please check your present product as to which plug you must use. Using the wrong plug may cause air leakage and incorrect readings.
  2. Check the air tube.
    • Make sure that the air tube protrudes from the [ ] mark on the cuff as the illustration shown below.
  3. Have the patient rest the arm with the palm facing up.
    • The arm cuff must be attached on the right upper arm.
    • If the arm cuff is wrapped over a thick cloth or the patient's sleeve is rolled up and pressure is applied on the arm, an accurate measurement result will not be obtained.
  4. Place the cuff on the upper arm. Align the [ ] mark on the arm cuff with the artery on the inner side of the upper arm.
    How to Apply the Arm Cuff - Step 2
  5. The bottom edge of the arm cuff must be 1 to 2 cm above the inside elbow.
  6. Wrap the cuff securely with both hands, so it can not move around patient's arm.
    How to Apply the Arm Cuff - Step 3
    • Make sure that the air tube is positioned on the inside of patient's arm.
    • The cuff does not have to be wrapped aligning the edges. Still correct measurement will be obtained.
    • If the [ ] mark is positioned out of range of the [ ] mark as the illustration below, that means the patient's arm circumference and the size of the cuff don't match. Choose an appropriate cuff and reapply it
      How to Apply the Arm Cuff - Step 4
    • If the cuff is not wrapped securely around the patient's arm, the arm may become numb or a measurement cannot be taken accurately.
  7. Keep the arm with the cuff attached at the level of the heart.
    • For correct measurements, keep the cuff level flush with the patient's heart.

Maintenance Procedures

Wiping
Wipe the cuff using a soft cloth moistened with the diluted alcohol or diluted neutral (mild) detergent.

Specifications

Product description Small size adult arm cuff Medium size adult arm cuff Large size adult arm cuff
Model HEM-CS19-PD
HEM-CS19
HEM-CR19-PD
HEM-CR19
HEM-CL19-PD
HEM-CL19
Arm circumference 17 - 22 cm 22 - 32 cm 32 - 42 cm
Cuff dimensions
(approximately value)
111 x 357 mm 146 x 517 mm 174 x 649 mm
Air tube length 1.5 m
Cuff pressure range Pressure: 0 to 299 mmHg
Accuracy Pressure: ±3 mmHg
Classification Class I
Operating conditions +10 to +40°C, 15 to 90% RH (non-condensing), 700 to 1060 hPa
Storage/Transport conditions -20 to +60°C, 10 to 95% RH (non-condensing), 700 to 1060 hPa
Package contents Cuff, 2 air plugs, instruction manual
Durable period 1 years or 20,000 times of use, whichever (Service life) comes first.

Symbols description

Symbols description

  • Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious incident that has occurred in relation to this device.
Manufacturer OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002
JAPAN
EU-representative OMRON HEALTHCARE EUROPE B.V.
Wegalaan 73, 2132 JD Hoofddorp, THE NETHERLANDS
www.omron-healthcare.com
Importer in EU
Asia Pacific HQ OMRON HEALTHCARE SINGAPORE PTE LTD.
438B Alexandra Rd, #08-01/02 Alexandra Technopark, Singapore 119968
www.omronhealthcare-ap.com
Production Facility OMRON HEALTHCARE Co., Ltd.
Mastsusaka Factory 1855-370, Kubo-cho, Matsusaka-shi, Mie, 515-8503
JAPAN
Importer in the United Kingdom and UK responsible person OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, UK
www.omron-healthcare.com/distributors
Subsidiaries OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
www.omron-healthcare.com/distributors
OMRON SANTÉ FRANCE SAS
www.omron-healthcare.com/distributors

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Omron HEM-907, HEM-CS19-PD, HEM-907-E Manual

Advertisement

Need help?

Need help?

Do you have a question about the HEM-907 and is the answer not in the manual?

Questions and answers

Table of Contents