Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference
after reading it thoroughly.
ACP 5
PACP5A000
MFL69981506
Rev.02_101023
[Representative] 143160, Russian Federation, Moscow region,
Ruza city district, territory of Minsk highway, kilometer 86, house 9
[Manufacturer] LG Electronics Inc. 84, Wanam-ro, Seongsan-gu,
Copyright © 2019 - 2023 LG Electronics Inc. All Rights Reserved.
Changwon-si, Gyeongsangnam-do, KOREA
www.lg.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the ACP 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for LG ACP 5

  • Page 1 [Representative] 143160, Russian Federation, Moscow region, Ruza city district, territory of Minsk highway, kilometer 86, house 9 [Manufacturer] LG Electronics Inc. 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA www.lg.com MFL69981506 Rev.02_101023 Copyright © 2019 - 2023 LG Electronics Inc. All Rights Reserved.
  • Page 2 SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS This product must be installed by an installation professional from an LG authorised service center. Any issues stemming from an installation by an unauthorised person is the responsibility of the user and will not be covered by warranty.
  • Page 3 SAFETY INSTRUCTIONS • Read the manual thoroughly to correctly install the product. - If not, an incorrect installation may cause fire or electric shock. • When wiring the product, do not use a non-standard cable, nor extend the cable excessively. - It may cause a fire or electric shock.
  • Page 4 SAFETY INSTRUCTIONS • Do not use the product for the preservation of animals and plants, precision instruments, art pieces, or for other special purposes. - It may cause property damage. • Dispose the packing material safely. - The packing material may result in personal injuries. CAUTION Installation •...
  • Page 5 SAFETY INSTRUCTIONS Class A device NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 6 • Up to 16 AHU can be interlocked ACP 5 Components Inside the packaged box of the ACP 5, there are the components as in the following drawing. Open the packaged box of the ACP 5, and check if all of the corresponding components are included.
  • Page 7 For software update and data backup and Lonworks ⑧ USB port Commission with U60FT module ⑨ Power switch Switch to turn on or off the power of the ACP 5 ⑩ Ethernet port Ethernet port to connect to internet and AC Manager 5 ⑪ SD card slot...
  • Page 8 ACP 5 FUNCTIONS AND SPECIFICATION ACP 5 Hardware specification ACP 5 hardware specification is as follows. Category Description ① Operating temperature 0 °C ~ 40 °C ② Rated voltage 12 V ③ Rated current Max 2.3 A • Ethernet 10 / 100 BASE-T •...
  • Page 9 Installing ACP 5 This chapter describes how to install the ACP 5 to use. In order to use the ACP 5, the installation should be performed by the following order. STEP 1. Check the cautions during the ACP 5 installation Before installing the ACP 5, check the cautions.
  • Page 10 • The number of the indoor units that can be connected to one ACP 5. One ACP 5 can be connected up to 256 CAUTION indoor units. With ACS I/O interlocking, you can connect 128 indoor units and 16 I/O RS-485 Connection of the ERV equipment modules.
  • Page 11 When the ACP 5 is interconnected with the AC Manager 5, the ERV can be installed together and controlled. The above figure shows the example that sets the address of 11 to the ERV and...
  • Page 12 RS-485, and LAN cable. considering the environment of the site. • Install DIN RAIL. • Hook the top part of the ACP 5 on DIN RAIL. • Push the main body of the ACP 5 until you hear the sound of installation.
  • Page 13 INSTALLING ACP 5 Fixing the ACP 5 to the wall ACP 5 can be installed by fixing to the wall. To install the ACP 5 in an adequate place, proceed according to the following explanation. It explains here on how to install...
  • Page 14 After connecting the ACP 5 to various devices via the cable, the network environment of the In such case, Ethernet cable shall be ACP 5 should be set by driving the ACP 5. The connected as a cross cable. following information should be set for using Use Ethernet cable (cross cable) to connect to the ACP 5.
  • Page 15 Turn on the ACP 5 to set the network environment of the ACP 5. When the power switch is turned on, the ACP 5 booting screen is displayed on the LCD as shown at the following figure, and when booting is completed, the initial ACP 5 screen is displayed.
  • Page 16 The following explains how to log in and out of ACP 5. ACP 5, can be controlled either by the equipment or the web. If you enter the IP address of the ACP 5 in the address bar of the command window of web browser (Run>cmd>ipconfig) without the installation of another program, the central control program ACP 5 Web server is executed automatically.
  • Page 17 User manual You can view the user manual as follows. In ACP 5 log-in screen, input ID and password and touch [Log in] button. Press 'Help' at the top right side of ACP 5 screen. - The user manual is displayed.
  • Page 18 Web GUI does Please check LAN cable and the power supply of Hub. not run. ACP 5 in the lock feature is enabled, the remote control Indoor remote control does function is not set.Peak control state must function setting not work.