Table 1-6. LCD Status Messages
Code
Text
N/A
SYSTEM NAME
E1000
FAILSAFE, Call
Support
E1114
Temp Ambient
E1116
Temp Memory
E12 nn
xx PwrGd
E1210
CMOS Batt
E1211
ROMB Batt
E1229
CPU # VCORE
E1310
RPM Fan ##
E1313
Fan Redundancy
20
About Your System
Causes
A 62-character string that can be
defined by the user in the System
Setup program.
The SYSTEM NAME displays
under the following conditions:
• The system is powered on.
• The power is off and active
POST errors are displayed.
Ambient system temperature is
out of acceptable range.
Memory has exceeded acceptable
temperature and has been
disabled to prevent damage to the
components.
Specified voltage regulator has
failed.
CMOS battery is missing, or the
voltage is out of acceptable range.
RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.
Processor # VCORE voltage
regulator has failed.
RPM of specified cooling fan is
out of acceptable operating range.
The system is no longer fan-
redundant. Another fan failure
will put the system at risk of over-
heating.
Corrective Actions
This message is for information
only.
You can change the system ID
and name in the System Setup
program. See "Using the System
Setup Program" on page 37.
See "Getting Help" on page 147.
See "Troubleshooting System
Cooling Problems" on page 119.
See "Troubleshooting System
Cooling Problems" on page 119.
See "Getting Help" on page 147.
See "Troubleshooting the System
Battery" on page 118.
Reseat the RAID battery
connector. See "RAID Battery" on
page 74, and "Troubleshooting
System Cooling Problems" on
page 119.
See "Getting Help" on page 147.
See "Troubleshooting System
Cooling Problems" on page 119.
Check control panel LCD for
additional scrolling messages. See
"Troubleshooting System Cooling
Problems" on page 119.

Hide quick links: