Advertisement

GRUNDFOS Sololift2 C-3 Manual

Symbols used in this document


If these safety instructions are not observed, it may result in personal injury.

The surface of the product may be so hot that it may cause burns or personal injury.

If these safety instructions are not observed, it may result in malfunction or damage to the equipment.
Note
Notes or instructions that make the job easier and ensure safe operation.

General description

The C-3 is a small, compact automatic lifting station suitable for pumping grey wastewater off places where it cannot be led directly to the sewer by means of a natural downward slope.

If you are away for a long period (e.g. holidays), we recommend that you turn off the water supply to the units served by the lifting station.

Applications

The product is suitable for pumping grey wastewater from a washing machine, dishwasher, kitchen sink, bath tub, shower or water softeners.
Note
The product must be fastened to the floor to prevent uplift and turning.

Pumped liquids

Grey wastewater up to 90°C.
Brine from water softeners with a maximum temperature of 20°C and maximum 15% of salt. Ordinary liquids for cleaning of the appliances connected. pH value: 4-10.

The product must not pump harsh chemicals or solvents. See the quick guide.

Installation


Do not pull or lift the product by the power supply cable.
Note
We strongly recommend that you install an LC A2 alarm device (accessory) if a washing machine, dishwasher, bathtub and/or a shower are connected to the lifting station.
The LC A2 will emit an acoustic alarm and switch off the washing machine or dishwasher if the water level in the tank becomes too high.
The product must be accessible for maintenance and repair.
The product must be placed in a frost-free room to prevent the pumped liquid from freezing.
Make sure that all external pipework is adequately insulated.
Note
The outlet pipe must be made of rigid material, such as copper, or of rigid PVC with solvent-welded joints.
To prevent the transmission of vibrations to buildings, make sure that the pipework is thoroughly fixed and that fittings cannot move and are not in contact with building parts.

Electrical connection

Make sure that the product is suitable for the supply voltage and frequency available at the installation site.
The electrical connection must be carried out in accordance with local regulations.

The product must be earthed. The protective earth of the socket outlet must be connected to the protective earth of the pump. The plug must therefore have the same PE connection system as that of the socket outlet. If not, use a suitable adapter.
The installation must include an earth leakage circuit breaker for protection against earth fault currents. This ensures protection when using a Schuko plug or another plug with earth pin.

The product must be connected to a mains switch with a minimum contact gap of 3 mm in all poles.
The thermal switch cuts out the motor in case of overtemperature and cuts it in again automatically after cooling.

Service


The product must only be serviced by trained service staff.
If the power supply cable is damaged, it must be replaced by the manufacturer, the manufacturer's service partner or a similarly qualified person.
To ensure safe and reliable operation, always use original spare parts from Grundfos.
For service kits, see www.productselection.grundfos.com.
Note
The product must be thoroughly cleaned before it is returned for service. Otherwise the warranty will be void.

Service documentation

Service documentation is available at www.productselection.grundfos.com.
Note
If you have any questions, please contact the nearest Grundfos company or service workshop.

Maintenance

The lifting station does not require any special maintenance, but we recommend that you check operation and pipe connections at least once a year.
Note
If the lifting station is connected to a washing machine or kitchen sink, we recommend that you check the float switch unit every six months for fibres and grease/fat.
Change the carbon filter once a year. See section Service instructions.

Service instructions

Thanks to the product design, service is easy in case of malfunction or blocked pump.
burn hazard The product may contain hot water.
The surface of the product may be so hot that it may cause burns or personal injury!

Before carrying out any service work, remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on.
All rotating parts must have stopped moving.
The product must only be serviced by trained service staff.

  1. Impeller stuck
    1. Disconnect the power supply.
      If Impeller stuck - Step 1
    2. Unscrew the cover.
      If Impeller stuck - Step 2 - Unscrew the cover
    3. Turn the motor shaft to the right and left with a screwdriver inserted into the slot in the shaft end to free the impeller from dirt.
      If Impeller stuck - Step 3 - Turn the motor shaft
    4. Fit the cover, and switch on the power supply to check if the impeller can rotate freely.
      If Impeller stuck - Step 4 - Fit the cover
  2. Operation by means of a power drill
    1. If the product cannot be operated by electrical power, disconnect the power supply and empty the tank by means of a power drill.
      Operation by means of a power drill
  3. Foreign body in tank
    1. If the water level in the tank is above the motor flange, disconnect the power supply and drain the tank by means of the drain hose.
      If Foreign body in tank - Step 1
    2. Unscrew the cover.
      If Foreign body in tank - Step 2
    3. Remove the four screws of the motor flange.
      If Foreign body in tank - Step 3
    4. Lift the motor flange to reduce the compression of the O-ring. Insert a screwdriver into the notch underneath the power supply cable and press it down.
      If Foreign body in tank - Step 4
    5. Lift out the complete motor-pump unit by the handles.
      If Foreign body in tank - Step 5
      Note
      Lift the unit vertically before tilting it.
    6. Check and clean the impeller, the protecting tube of the float switch and the tank.
      If Foreign body in tank - Step 6
      Note
      Check that the float switch works properly before fitting the cover.
  4. Float switch pipe blocked
    Note
    The float switch unit can be removed separately.
    If the water level in the tank is above the motor flange, disconnect the power supply and drain the tank by means of the drain hose. See 3.1.
    1. If Float switch pipe blocked - Step 1
      Unscrew the cover.
      Turn the bayonet coupling 10 ° clockwise.
      Pull out the float switch unit.
      Press in the two tabs on the protecting tube.
      Pull down the protecting tube.
    2. Check and clean the float switch pipe.
      If Float switch pipe blocked - Step 2
      Note
      Check that the float switch works properly before fitting the cover.
      Note
      Lubricate the O-ring seat of the float switch in the motor flange for easier fitting.
  5. Carbon filter
    1. Replace the carbon filter once a year to ensure sufficient filter function.
      Note
      Instead of using a carbon filter, Sololift can also be vented through a venting pipe. In this case a venting valve is needed. Product number: 98059587.

Technical data

Supply voltage
1 x 220-240 V - 10%/+ 6%, 50 Hz.
Power consumption
640 W.
Power factor
Cos φ 0.66/0.90.
Speed
2800 min-1.
Rated current
3.1 A.
Insulation class
F.
Noise level
< 70 dB(A) to 12050-2.
Flow rate
Max. 204 l/min.
System pressure
Max. pump head: 8.0 m.
Max system head: 6.0 m.
Note
The system pressure must not exceed 6 m head to guarantee a sufficient drain of the connected sanitary appliances.
Supply cable
1.2 m, 0.75 mm2 (H05VV-F-3G).
Net weight
6.6 kg.
Start and stop levels
Start level 1: 65 mm above floor level.
Start level 2: 115 mm above floor level.
Stop level: 35 mm above floor level.
Liquid temperature
75°C continuously (90°C for 30 minutes).
Brine from a water softener: maximum 20°C.
Brine
Maximum 15% of salt.
Ambient temperature
+5°C to +35°C.
Duty
S3 - 50% - 1 minute (30 seconds on; 30 seconds off).

Fault finding


Remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on.
All rotating parts must have stopped moving.
The product must only be serviced by trained service staff.
See also section Service instructions.

Fault Cause Remedy
  1. Motor does not start when the level in the tank reaches the start level.
  1. Supply failure.
Reestablish the power supply.
  1. Fuse blown. If new fuse blows at once, either cable or motor is faulty.
Replace the fuse.
Measure cable and motor. If cable or motor is defective, replace the defective parts.
  1. Impeller stuck. Thermal switch tripped.
Free the impeller, and wait until the motor is cooled down and the thermal switch has reset.
  1. Float switch stuck.
Remove the float switch and clean the pipe.
  1. Motor hums but does not operate.
  1. Impeller stuck.
Free the impeller and check that it can rotate freely.
  1. Motor or capacitor defective.
Replace the motor or capacitor.
  1. Motor runs continuously or at irregular intervals.
  1. Water leaking from inlet into tank.
Check for leaking appliances.
  1. Water leaking back into tank from the outlet pipe.
Check the non-return flap.
  1. Float switch defective or stuck.
Clean the float switch unit or replace it, if necessary.
  1. Motor runs but does not evacuate water.
  1. Pump or tank blocked.
Remove blockage.
  1. Air lock in pump or vent hole in pump housing blocked.
Check operation of vent valve in the tank.
Check that the carbon filter is not wet.
Check that the vent hole in the pump housing is not blocked.
  1. Outlet port or pipe blocked.
Remove blockage.
Check the non-return flap.
  1. The lifting station evacuates slowly.
  1. The outlet pipe is too long or has an excessive number of bends.
Increase the outlet pipe size (maximum 40 mm).
Change pipework to reduce number of bends.
Change bends to soft bends.
  1. The pump housing is leaky.
Replace the pump housing (service part).
  1. Hydraulics blocked.
Check that the motor shaft can rotate freely. Remove the motor flange to clean the impeller.
  1. Rattling noise from the lifting station, but water is evacuated.
  1. Foreign body hitting the impeller.
Remove the foreign body.
  1. Odour from the tank.
  1. Carbon filter contaminated.
Replace the carbon filter.
  1. Water from shower or another appliance connected to the lower inlets drains off slowly. Backflow from the lifting station.
  1. Hydraulics blocked.
Check that the motor shaft can rotate freely. Remove the motor flange to clean the impeller.
  1. The start level has changed.
Check and clean the float switch pipe.
  1. Inlet pipe diameter is too small.
Use a pipe with a larger diameter.

Argentina
Bombas GRUNDFOS de Argentina S.A.
Ruta Panamericana km. 37.500 Centro
Industrial Garin 1619 Garín Pcia. de B.A.
Phone: +54-3327 414 444
Telefax: +54-3327 45 3190

Australia
GRUNDFOS Pumps Pty. Ltd.
P.O. Box 2040
Regency Park
South Australia 5942
Phone: +61-8-8461-4611
Telefax: +61-8-8340 0155

Austria
GRUNDFOS Pumpen Vertrieb
Ges.m.b. H.
Grundfosstraße 2
A-5082 Grödig/Salzburg
Tel.: +43-6246-883-0
Telefax: +43-6246-883-30

Belgium
N.V. GRUNDFOS Bellux S.A.
Boomsesteenweg 81-83
B-2630 Aartselaar
Tél.: +32-3-870 7300
Télécopie: +32-3-870 7301

Belarus
Представительство ГРУНДФОС в Минске
220125, Минск ул. Шафарнянская, 11, оф. 56, БЦ «Порт»
Тел.: +7 (375 17) 286 39 72/73
Факс: +7 (375 17) 286 39 71
E-mail: minsk@grundfos.com

Bosnia and Herzegovina
GRUNDFOS Sarajevo
Zmaja od Bosne 7-7A,
BH-71000 Sarajevo
Phone: +387 33 592 480
Telefax: +387 33 590 465
www.ba.grundfos.com
e-mail: grundfos@bih.net.ba

Brazil
BOMBAS GRUNDFOS DO BRASIL
Av. Humberto de Alencar Castelo
Branco, 630
CEP 09850 - 300
São Bernardo do Campo - SP
Phone: +55-11 4393 5533
Telefax: +55-11 4343 5015

Bulgaria
Grundfos Bulgaria EOOD
Slatina District
Iztochna Tangenta street no. 100
BG - 1592 Sofia
Tel. +359 2 49 22 200
Fax. +359 2 49 22 201
email: bulgaria@grundfos.bg

Canada
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario
L6H 6C9
Phone: +1-905 829 9533
Telefax: +1-905 829 9512

China
GRUNDFOS Pumps (Shanghai) Co. Ltd.
10F The Hub, No. 33 Suhong Road
Minhang District
Shanghai 201106
PRC
Phone: +86 21 612 252 22
Telefax: +86 21 612 253 33

Croatia
GRUNDFOS CROATIA d.o.o.
Buzinski prilaz 38, Buzin
HR-10010 Zagreb
Phone: +385 1 6595 400
Telefax: +385 1 6595 499
www.hr.grundfos.com

Czech Republic
GRUNDFOS s.r.o.
Čajkovského 21
779 00 Olomouc
Phone: +420-585-716 111
Telefax: +420-585-716 299

Denmark
GRUNDFOS DK A/S
Martin Bachs Vej 3
DK-8850 Bjerringbro
Tlf.: +45-87 50 50 50
Telefax: +45-87 50 51 51
E-mail: info_GDK@grundfos.com
www.grundfos.com/DK

Estonia
GRUNDFOS Pumps Eesti OÜ
Peterburi tee 92G
11415 Tallinn
Tel: + 372 606 1690
Fax: + 372 606 1691

Finland
OY GRUNDFOS Pumput AB
Trukkikuja 1
FI-01360 Vantaa
Phone: +358-(0) 207 889 500
Telefax: +358-(0) 207 889 550

France
Pompes GRUNDFOS Distribution S.A.
Parc d'Activités de Chesnes
57, rue de Malacombe
F-38290 St. Quentin Fallavier (Lyon)
Tél.: +33-4 74 82 15 15
Télécopie: +33-4 74 94 10 51

Germany
GRUNDFOS GMBH
Schlüterstr. 33
40699 Erkrath
Tel.: +49-(0) 211 929 69-0
Telefax: +49-(0) 211 929 69-3799
e-mail: infoservice@grundfos.de
Service in Deutschland:
e-mail: kundendienst@grundfos.de

Greece
GRUNDFOS Hellas A.E.B.E.
20th km. Athinon-Markopoulou Av.
P.O. Box 71
GR-19002 Peania
Phone: +0030-210-66 83 400
Telefax: +0030-210-66 46 273

Hong Kong
GRUNDFOS Pumps (Hong Kong) Ltd.
Unit 1, Ground floor
Siu Wai Industrial Centre
29-33 Wing Hong Street &
68 King Lam Street, Cheung Sha Wan
Kowloon
Phone: +852-27861706/27861741
Telefax: +852-27858664

Hungary
GRUNDFOS Hungária Kft.
Park u. 8
H-2045 Törökbálint,
Phone: +36-23 511 110
Telefax: +36-23 511 111

India
GRUNDFOS Pumps India Private Limited
118 Old Mahabalipuram Road
Thoraipakkam
Chennai 600 096
Phone: +91-44 2496 6800

Indonesia
PT. GRUNDFOS POMPA
Graha Intirub Lt. 2 & 3
Jln. Cililitan Besar No.454. Makasar,
Jakarta Timur
ID-Jakarta 13650
Phone: +62 21-469-51900
Telefax: +62 21-460 6910/460 6901

Ireland
GRUNDFOS (Ireland) Ltd.
Unit A, Merrywell Business Park
Ballymount Road Lower
Dublin 12
Phone: +353-1-4089 800
Telefax: +353-1-4089 830

Italy
GRUNDFOS Pompe Italia S.r.l.
Via Gran Sasso 4
I-20060 Truccazzano (Milano)
Tel.: +39-02-95838112
Telefax: +39-02-95309290/95838461

Japan
GRUNDFOS Pumps K.K.
1-2-3, Shin-Miyakoda, Kita-ku,
Hamamatsu
431-2103 Japan
Phone: +81 53 428 4760
Telefax: +81 53 428 5005

Korea
GRUNDFOS Pumps Korea Ltd.
6th Floor, Aju Building 679-5
Yeoksam-dong, Kangnam-ku, 135-916
Seoul, Korea
Phone: +82-2-5317 600
Telefax: +82-2-5633 725

Latvia
SIA GRUNDFOS Pumps Latvia
Deglava biznesa centrs
Augusta Deglava ielā 60, LV-1035, Rīga,
Tālr.: + 371 714 9640, 7 149 641
Fakss: + 371 914 9646

Lithuania
GRUNDFOS Pumps UAB
Smolensko g. 6
LT-03201 Vilnius
Tel: + 370 52 395 430
Fax: + 370 52 395 431

Malaysia
GRUNDFOS Pumps Sdn. Bhd.
7 Jalan Peguam U1/25
Glenmarie Industrial Park
40150 Shah Alam
Selangor
Phone: +60-3-5569 2922
Telefax: +60-3-5569 2866

Mexico
Bombas GRUNDFOS de México S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
Apodaca, N.L. 66600
Phone: +52-81-8144 4000
Telefax: +52-81-8144 4010

Netherlands
GRUNDFOS Netherlands
Veluwezoom 35
1326 AE Almere
Postbus 22015
1302 CA ALMERE
Tel.: +31-88-478 6336
Telefax: +31-88-478 6332
E-mail: info_gnl@grundfos.com

New Zealand
GRUNDFOS Pumps NZ Ltd.
17 Beatrice Tinsley Crescent
North Harbour Industrial Estate
Albany, Auckland
Phone: +64-9-415 3240
Telefax: +64-9-415 3250

Norway
GRUNDFOS Pumper A/S
Strømsveien 344
Postboks 235, Leirdal
N-1011 Oslo
Tlf.: +47-22 90 47 00
Telefax: +47-22 32 21 50

Poland
GRUNDFOS Pompy Sp. z o.o.
ul. Klonowa 23
Baranowo k. Poznania
PL-62-081 Przeźmierowo
Tel: (+48-61) 650 13 00
Fax: (+48-61) 650 13 50

Portugal
Bombas GRUNDFOS Portugal, S.A.
Rua Calvet de Magalhães, 241
Apartado 1079
P-2770-153 Paço de Arcos
Tel.: +351-21-440 76 00
Telefax: +351-21-440 76 90

Romania
GRUNDFOS Pompe România SRL
Bd. Biruintei, nr 103
Pantelimon county Ilfov
Phone: +40 21 200 4100
Telefax: +40 21 200 4101
E-mail: romania@grundfos.ro

Russia
ООО Грундфос Россия
109544, г. Москва, ул. Школьная, 39-41, стр. 1
Тел. (+7) 495 564-88-00 (495) 737-30-00
Факс (+7) 495 564 88 11
E-mail grundfos.moscow@grundfos.com

Serbia
Grundfos Srbija d.o.o.
Omladinskih brigada 90b
11070 Novi Beograd
Phone: +381 11 2258 740
Telefax: +381 11 2281 769
www.rs.grundfos.com

Singapore
GRUNDFOS (Singapore) Pte. Ltd.
25 Jalan Tukang
Singapore 619264
Phone: +65-6681 9688
Telefax: +65-6681 9689

Slovakia
GRUNDFOS s.r.o.
Prievozská 4D
821 09 BRATISLAVA
Phona: +421 2 5020 1426
sk.grundfos.com

Slovenia
GRUNDFOS LJUBLJANA, d.o.o.
Leskoškova 9e, 1122 Ljubljana
Phone: +386 (0) 1 568 06 10
Telefax: +386 (0)1 568 06 19
E-mail: tehnika-si@grundfos.com

South Africa
GRUNDFOS (PTY) LTD
Corner Mountjoy and George Allen Roads
Wilbart Ext. 2
Bedfordview 2008
Phone: (+27) 11 579 4800
Fax: (+27) 11 455 6066
E-mail: lsmart@grundfos.com

Spain
Bombas GRUNDFOS España S.A.
Camino de la Fuentecilla, s/n
E-28110 Algete (Madrid)
Tel.: +34-91-848 8800
Telefax: +34-91-628 0465

Sweden
GRUNDFOS AB
Box 333 (Lunnagårdsgatan 6)
431 24 Mölndal
Tel.: +46 31 332 23 000
Telefax: +46 31 331 94 60

Switzerland
GRUNDFOS Pumpen AG
Bruggacherstrasse 10
CH-8117 Fällanden/ZH
Tel.: +41-44-806 8111
Telefax: +41-44-806 8115

Taiwan
GRUNDFOS Pumps (Taiwan) Ltd.
7 Floor, 219 Min-Chuan Road
Taichung, Taiwan, R.O.C.
Phone: +886-4-2305 0868
Telefax: +886-4-2305 0878

Thailand
GRUNDFOS (Thailand) Ltd.
92 Chaloem Phrakiat Rama 9 Road,
Dokmai, Pravej, Bangkok 10250
Phone: +66-2-725 8999
Telefax: +66-2-725 8998

Turkey
GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
Gebze Organize Sanayi Bölgesi
Ihsan dede Caddesi,
2. yol 200. Sokak No. 204
41490 Gebze/ Kocaeli
Phone: +90 - 262-679 7979
Telefax: +90 - 262-679 7905
E-mail: satis@grundfos.com

Ukraine
Бізнес Центр Європа
Столичне шосе, 103
м. Київ, 03131, Україна
Телефон: (+38 044) 237 04 00
Факс.: (+38 044) 237 04 01
E-mail: ukraine@grundfos.com

United Arab Emirates
GRUNDFOS Gulf Distribution
P.O. Box 16768
Jebel Ali Free Zone
Dubai
Phone: +971 4 8815 166
Telefax: +971 4 8815 136

United Kingdom
GRUNDFOS Pumps Ltd.
Grovebury Road
Leighton Buzzard/Beds. LU7 4TL
Phone: +44-1525-850000
Telefax: +44-1525-850011

U.S.A.
GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Telefax: +1-913-227-3500

Uzbekistan
Grundfos Tashkent, Uzbekistan The Representative Office of Grundfos Kazakhstan in Uzbekistan 38a, Oybek street, Tashkent
Телефон: (+998) 71 150 3290/71 150 3291
Факс: (+998) 71 150 3292

www.grundfos.com

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download GRUNDFOS Sololift2 C-3 Manual

Advertisement

Need help?

Need help?

Do you have a question about the Sololift2 C-3 and is the answer not in the manual?

Questions and answers

Table of Contents