Repairs other than those described here should be performed only by trained, qualified personnel. Contact SENCO for information at 1-800-543-4596.
A = Kit #YK0370
SYMPTOM | SOLUTION |
Air leak near top of tool/Sluggish operation | Verify air supply/tighten screws or install Parts Kit YK0370. |
Air leak near bottom of tool/Poor return. | Clean tool/tighten screws or install Parts Kit YK0370. |
Other problems. | Contact SENCO. |
SENCO offers a full line of accessories for your SENCO tools, including:
For more information or a complete illustrated catalogue of SENCO accessories, ask your representative for #MK336.
Minimum to maximum operating pressure | 80-110 psi | 5,5-7,5 bar |
Air Consumption (60 cycles per minute) | 3.79 scfm | 107.3 liter |
Air Inlet | 3/8 in. NPT | 3/8 in NPT |
Maximum Speed (cycles per second) | – | – |
Weight | 6.3 lbs. | 2,8 kg |
Staple Capacity | 120 | 120 |
Tool size: Height | 9 13/16 in. | 249 mm |
Tool size: Length | 12 11/16 in. | 322 mm |
Tool size: Width: Main Body | 3 3/16 in. | 81 mm |
Tool size: Width: Rear Bracket | – | – |
H | J | L | |
Y05 | 7/16" 11 mm | .020 in.(25ga) .51mm | 5/16" 8 mm |
Y07 | 7/16" 11 mm | .020 in.(25ga) .51mm | 7/16" 11 mm |
Y09 | 7/16" 11 mm | .020 in.(25ga) .51mm | 9/16" 14 mm |