Download Print this page

MedNet TC200 User Manual

Hand tremor data collector

Advertisement

Quick Links

User Manual
Hand Tremor Data Collector
Model TC200
Version: TC200-EN-V3.6
- 1 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the TC200 and is the answer not in the manual?

Questions and answers

Summary of Contents for MedNet TC200

  • Page 1 User Manual Hand Tremor Data Collector Model TC200 Version: TC200-EN-V3.6 - 1 -...
  • Page 2 DEFINITIONS WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in invalid data collecting ,damage to the equipment or invalid operation. NOTICE: Information necessary to be known before using the equipment.
  • Page 3: Intended Use

    1 INTENDED USE The hand tremor data collector is used to collect hand tremor data of user with Parkinson's Disease, Parkinson’s Syndrome, Essential Tremor, or other physical disabilities. It can also be used as an assistive equipment to eat. - 3 -...
  • Page 4 2 SAFETY INFORMATION WARNING 1 Do not place or store the equipment near fire or heat articles. 2 Do not use a damaged charging cable or socket. For patients with pacemakers or other electrical stimulation devices, please do not place the product near your heart or other electrical stimulation devices due to the magnetic components of the product.
  • Page 5: Know Your Unit

    3 KNOW YOUR UNIT The equipment can collect tremor data of user by built-in sensors and transfer the data via WIFI. It can also detect and offset shaking of hand to help user eat smoothly. Components Figure 1 Components - 5 -...
  • Page 6 Handle Figure 2 Handle Side View Item Description Connecting point to attachments Front part of handle Distance sensor Soft sleeve Twist button Rear part of handle Table 1 Handle Side View Description Figure 3 Handle Rear View Item Description Power button Short press: Turn on or off the equipment Long press for 5 seconds: Enter WiFi configuration mode Indicating light to identify different status...
  • Page 7 Attachment Figure 4 Spoon Attachment - 7 -...
  • Page 8: Symbols Used

    4 SYMBOLS USED General warning sign General caution sign Notice sign Refer to user manual. WEEE-Properly dispose of electronic waste Type BF applied part Non-ionizing radiation CE mark Universal recycling sign IP24 IP24 degree of protection Direct current Indicates the authorized representative in the European Community Indicates the item is a medical device Table 3 Symbols Used by this Equipment - 8 -...
  • Page 9: Specifications

    5 SPECIFICATIONS Approx. 233 (L) * 52.5 (W) * 31.5 (H) (mm) Dimensions Total Weight ≈ 155 g Spoon Weight ≈ 6.7 g Fork Weight ≈ 5.4 g Frequency: 3 Hz to 8Hz Measurement Range Amplitude: 6 mm to 100 mm Frequency: 0.1 Hz Resolution Amplitude: 1 mm...
  • Page 10 6 INDICATING LIGHT DESCRIPTION Color Status Device charging Green Fully charged Alternating yellow and green Fully charged,WiFi not connected Charging Alternating yellow and red Charging,WiFi not connected Flashing in blue WiFi connected or data transferring Flashing in yellow Under WiFi configuration Equipment in use Breathing in green Standby...
  • Page 11: Download Mobile Application

    7 DOWNLOAD MOBILE APPLICATION “GYENNO SPOON” Please search for in the appropriate mobile application store, download and install it. www.gyenno.com/spoon2 “GYENNO SPOON”. You can also visit for downloading the mobile application Open the app on your smartphone and follow the WiFi configuration instructions. NOTICE: You can record and view your tremor data on the APP.
  • Page 12: Before Using

    8 BEFORE USING Attachments Installation The attachments will adhere to the handle by magnetic force when the attachments are placed near the handle as shown below. Figure 5 Installing Attachment How to Hold the Equipment Make sure the attachment is firmly connected to the handle before using. It is recommended to hold the equipment as shown below.
  • Page 13 Power On and Off Short press the power button to turn on or off the equipment. When the equipment is standby, the indicating light breaths in green. NOTICE The equipment will automatically turn off if it had not been working for 5 minutes. - 13 -...
  • Page 14: Taking A Measurement

    9 TAKING A MEASUREMENT When the equipment is on and once it detects tremor, data collecting will start. The indicating light breaths in blue. Figure 7 Taking a Measurement The data collecting process takes a few minutes (measurement period), when it is completed, the indicating light breaths in green.
  • Page 15 None or incomplete data transfer due to WiFi connection problems. The measurement is terminated. - 15 -...
  • Page 16 10 ASSIST TO EAT Shaking Offset Once the equipment detects tremor, the internal motors actively offset the shaking to keep stable. Figure 9 Vertical Shaking Offset Figure 10 Horizontal Shaking Offset Twist Function The equipment offers a twist function to help the user eat noodles, spaghetti, pasta, etc. Install the fork before using the twist function, press and hold the button to start twisting, loose the button after twisting the noodles, the fork will then reset to horizontal.
  • Page 17: After Using

    11 AFTER USING Attachments Uninstallation Please power off and uninstall the attachments after using. The handle should be placed horizontally. It is suggested that both the handle and attachments should be cleaned each time after using. Charging If the indicating light breaths in red, the equipment can still work for approximately 10 minutes. In order to protect the mechanic parts, please charge the equipment as soon as possible.
  • Page 18: Cleaning And Disinfection

    12 CLEANING AND DISINFECTION Attachments NOTICE The attachments should be cleaned before the first use. Please uninstall the attachments from the handle before cleaning. The attachments are suggested to wash with uten- sil detergent and water, they can also be cleaned in the dishwasher. Wipe the attachments with dry cloth. Do not submerge the attachments into detergent contains corrosive ingredient.
  • Page 19: Maintenance

    13 MAINTENANCE 1. The attachment should be uninstalled from the handle before cleaning. Use a small portion of utensil detergent and water to wash. 2. The attachment should not be submerged into detergent contains corrosive ingredient. 3. Any part of the handle is not waterproof, do not splash water on the handle or submerge it into water. Wipe and clean the handle with antibacterial tissue or cotton cloth soaked with alcohol.
  • Page 20: Troubleshooting

    14 TROUBLESHOOTING Problems Causes and solutions “GYENNO SPOON” The equipment is not registered in “GYENNO SPOON” Please register the equipment follow the instructions in The equipment is not connected to the WiFi. No data shown “GYENNO SPOON” Please configure the WiFi follow the instructions in Insufficient time for measurement Please refer to the section "Taking a measurement"...
  • Page 21 15 PRECAUTIONS It is suggested to use this equipment independently at the first time to avoid worse tremor caused by the anxiety and nervous since the users may have difficulties on daily eating and being taken care of. It is suggested to proactively adjust holding gestures and ways of sending food to mouth at the beginning of adopting the equipment.
  • Page 22 16 CONTRAINDICATIONS For patients with pacemakers or other electrical stimulation devices, please do not place the product near your heart or other electrical stimulation devices due to the magnetic components of the product. Users allergic to medical rubber are not recommended to use this equipment. - 22 -...
  • Page 23: Emc Information

    NOTE The EMISSIONS characteristics of TC200 make it suitable for use in industrial areas and hospitals (CISPR 11 class A). If it is used in a residential environment (for which CISPR 11 class B is normally required) TC200 might not offer ade- quate protection to radio-frequency communication services.
  • Page 24 Guidance and manufacture’s declaration – electromagnetic immunity TC200 is intended for use in the electromagnetic environment specified below. The customer or the user of TC200 should assure that they are used in such an environment. Immunity test IEC/EN 60601 test level...
  • Page 25 Guidance and manufacture’s declaration – electromagnetic immunity TC200 is intended for use in the electromagnetic environment specified below. The customer or the user of TC200 should assure that they are used in such an environment. Immunity test IEC/EN 60601 test level...
  • Page 26 Recommended separation distances between portable and mobile RF communications device and TC200 TC200 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of TC200 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communi- cations device (transmitters) and TC200 as recommended below, according to the maximum output power of the communications de- vice.
  • Page 27 Test specifications for enclosure port immunity to RF wireless communications device Maximum Test fre- Test fre- Band Distance Service Modulation power quency quency (MHz) (MHz) (MHz) 380-390 TETRA 400 Pulse modulation 18 Hz 430-470 GMRS 460, FRS 460 ± 5 kHz deviation 704-787 LTE Band 13, 17 Pulse modulation...
  • Page 28: Regulatory Information

    FCC RF Exposure Information and Statement The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: DTS (FCC ID: 2ACGF-TC200) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certi- fication for use at the body is 0.307 W/kg.
  • Page 29: Limited Warranty

    19 LIMITED WARRANTY Gyenno warrants the included hardware product against defects for 12 months (24 months in EU countries) from the date of original retail purchase. As for the attachments and accessories (charging cable), the warranty period is 6 months. Any part of the equipment, including attachments and accessories, is not allowed to be repaired by unspecified maintenance.
  • Page 30 20 DISPOSAL GYENNO has always been committed to earth care, we also encourage our users to make contribution by executing proper disposal: ● Packaging materials should be handed over recycling companies for possibility of re-use. ● Comply with relevant laws and regulations when disposing wasted parts and components. ●...
  • Page 31 21 COPYRIGHT AND RESPONSIBILITY The copyrights and confidentiality of this manual are owned by GYENNO. This manual is subjected to be a reference for operating and maintaining the equipment. - 31 -...
  • Page 32: Manufacturer Information

    MANUFACTURER INFORMATION Manufacturer GYENNO Technologies CO., LTD. 801-804 & 904,Building B2, Phase II, Creative City, Xian Dong Road, Xili Street, Address Nanshan District, Shenzhen, 518055, Guangdong, P.R. China Tel. 0086-4008033037 Email service@gyenno.com Website www.gyenno.com - 32 -...