Download Print this page
ABB Busch-Watchdog PRO Product Manual
Hide thumbs Also See for Busch-Watchdog PRO:

Advertisement

Quick Links

Product manual │ 12.08.2024
Busch-Watchdog
6851/9-xxx-500
Busch-Watchdog
6851/22-xxx-500
Busch-Watchdog
6851/22S-xxx-500
Busch-Watchdog
Branding -- Release 2018-01-01
®
PRO
®
90° BT
®
220° BT
®
220° select

Advertisement

loading
Need help?

Need help?

Do you have a question about the Busch-Watchdog PRO and is the answer not in the manual?

Questions and answers

Summary of Contents for ABB Busch-Watchdog PRO

  • Page 1 Product manual │ 12.08.2024 Busch-Watchdog ® 6851/9-xxx-500 Busch-Watchdog ® 90° BT 6851/22-xxx-500 Busch-Watchdog ® 220° BT 6851/22S-xxx-500 Busch-Watchdog ® 220° select Branding -- Release 2018-01-01...
  • Page 2: Table Of Contents

    Table of contents Table of contents Notes on the instruction manual ........................4 Safety ................................5 Information and symbols used ......................5 Intended use ............................6 Improper use ............................6 Target group / Qualifications of personnel ..................7 2.4.1 Operation ............................. 7 2.4.2 Installation, commissioning and maintenance ................
  • Page 3 Table of contents Cleaning ............................37 Notes ................................38 Index ................................39 Product manual 2CKA000073B5790 │3...
  • Page 4: Notes On The Instruction Manual

    If you pass the device on, also include this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. If you require additional information or have questions about the device, please contact ABB or visit our Internet site at: https://new.abb.com/en...
  • Page 5: Safety

    However, residual hazards remain. Read and adhere to the safety instructions to prevent hazards of this kind. ABB accepts no liability for any failure to observe the safety instructions. Information and symbols used The following Instructions point to particular hazards involved in the use of the device or provide...
  • Page 6: Intended Use

    Each use not listed in see chapter 2.2 “Intended use“ on page 6 is deemed improper use and can lead to personal injury and damage to property. ABB is not liable for damages caused by use deemed contrary to the intended use of the device. The associated risk is borne exclusively by the user/operator.
  • Page 7: Target Group / Qualifications Of Personnel

    Safety Target group / Qualifications of personnel 2.4.1 Operation No special qualifications are needed to operate the device. 2.4.2 Installation, commissioning and maintenance Installation, commissioning and maintenance of the device must only be carried out by trained and properly qualified electrical installers. The electrical installer must have read and understood the manual and follow the instructions provided.
  • Page 8: Safety Instructions

    Safety Safety instructions Danger - Electric voltage! Electric voltage! Risk of death and fire due to electric voltage of 100 … 240 V. Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death.
  • Page 9: Information On Protection Of The Environment

    Information on protection of the environment Information on protection of the environment Environment Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. – The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot.
  • Page 10: Setup And Function

    They switch connected loads via a timing element when sources of heat move within their detection range. ® The remote control and parameter setting is carried out via the app ABB-free@home Next App in the respectively most current version.
  • Page 11: Device Overview

    Setup and function Article No. Colour 6851/x-131 Brown, RAL 8017 6851/x-133 Aluminium silver, RAL 9006 6851/x-134 Studio white, RAL 9016 6851/x-135 Anthracite, RAL 7016 6851/x-136 Stainless steel Fig.2: Colour variations Device overview Fig. 1: Overview of devices 6851/9-xxx-500, 6851/22S-xxx-500 and 6851/22-xxx-500 Pos.
  • Page 12: Technical Data

    Technical data Technical data Designation Value Nominal voltage 230 V AC ± 10% 50/60 Hz Switching capacity 2300 W/VA Switching capacity LEDi 400 VA Maximum power loss < 0.3 W Twilight sensor Typ. 0.5 - 1000 / ∞ lux Switch-off delay 10 seconds - 30 minutes Short-time pulse Pulse duration...
  • Page 13 Technical data Technical data 6851/22S-xxx-500 Designation Value Front lens 220° select Horizontal detection 220° Maximum transmission range For mounting at 2.5 m hight 16 m in radius ■ ■ For mounting at 1.5 m height 16 m in radius ■ ■...
  • Page 14: Dimensional Drawings

    Technical data Dimensional drawings Fig. 2: Dimensions Fig. 3: Dimensions with design styling frame (optional) Notice All dimensions are in mm. Product manual 2CKA000073B5790 │14...
  • Page 15: Detection Range

    Technical data Detection range 90° BT 90° max. m max. max. 1 m 12 m Fig. 4: Detection range 6851/9-xxx-500 Detection range The detection range is 90°. ■ The maximum transmission range is 12 frontal and every 8 m lateral. ■...
  • Page 16 Technical data 220° select 220° select max. 16 m Fig. 6: Detection range 6851/22S-xxx-500 Detection range The detection range is 220°. ■ The maximum transmission range is 16 m in radius. ■ The vertical opening angle amounts to > 5°, and therefore makes detection with animal ■...
  • Page 17: Connection, Installation / Mounting

    Connection, installation / mounting Connection, installation / mounting Danger - Electric voltage! Electric voltage! Risk of death and fire due to electric voltage of 100 … 240 V. Dangerous currents flow through the body when coming into direct or indirect contact with live components.
  • Page 18: Electrical Connection

    Connection, installation / mounting Electrical connection Standard connection Fig. 7: Standard connection Standard connection with break switch Fig. 8: Standard connection with break switch After the break switch is actuated, the connected load is switched on for the duration of the switch-off delay.
  • Page 19 Connection, installation / mounting Terminal assignment [⏚] Green/yellow [L] Brown [N] Blue [↓] Grey The skinning length amounts to 11 mm. Fig. 10: Skinning length Attention! Protection of the skinned lengths – Do not remove the wire end sleeves on the device cables. Danger - Electric shock due to short-circuit! Risk of death due to electrical voltage of 100 to 240 V during short-circuit in the low-voltage line.
  • Page 20: Mounting

    Connection, installation / mounting Mounting Danger - Electric voltage! Risk of death and fire due to electric voltage of 100 to 240 V. – Work on the 100 - 240 V supply system may only be performed by authorised and qualified electricians. –...
  • Page 21 Connection, installation / mounting 4. Mount the base. – The bolting options [A] of the base are compatible with possibly available bores of older ® Busch-Watchdog – Do not use countersunk head screws for mounting the base. – Use screws with a head diameter of 6.5 mm - 8.5 mm. Fig.
  • Page 22 Connection, installation / mounting 7. Attach the cover so that the markings are above each other. Fig. 17: Aligning markings 8. Turn the cover clockwise until it latches with an audible click. Mounting the design styling frame (optional) Notice The Busch-Watchdog ®...
  • Page 23 Connection, installation / mounting Mounting the corner adapter (optional) Fig. 20: Mounting the corner adapter (optional) Notice The corner adapter (not included in the scope of delivery) can be used for corner mounting of 6851/22-xxx-500 and 6851/22S-xxx-500. Product manual 2CKA000073B5790 │23...
  • Page 24: Mounting Method

    Connection, installation / mounting Mounting method There are different types of mounting methods for Busch-Watchdog ® 6851/9-xxx-500 6851/22- xxx-500 and 6851/22S-xxx-500. Ceiling mounting Fig. 21: Ceiling mounting, example of canopy Wall mounting 6851/9-xxx-500 Fig. 22: Wall mounting on central terraced house 6851/9-xxx-500 Fig.
  • Page 25 Connection, installation / mounting Wall mounting 6851/22-xxx-500 2,5 m Fig.24: Wall mounting on free-standing one- family house 6851/22-xxx-500 Fig. 25: Wall mounting on free-standing one-family house with bottom lens 6851/22-xxx-500 Wall mounting in hillside location 6851/22-xxx-500 Wall mounting in hillside location, for example, is recommended on a building situated on a hill or with a gradient.
  • Page 26 Connection, installation / mounting Wall mounting 6851/22S-xxx-500 1,5 m Fig.27: Wall mounting on free-standing one- family house 6851/22S-xxx-500 Fig. 28: Wall mounting on free-standing one-family house without bottom lens 6851/22S-xxx-500 Mounting for curtain monitoring 6851/22S-xxx-500 Fig. 29: Mounting for curtain monitoring 6851/22S-xxx-500 Animal access 6851/22S-xxx-500 Fig.
  • Page 27: Adjusting The Transmission Range

    Connection, installation / mounting Adjusting the transmission range Adjusting the transmission range as follows: 1. Adjust the transmission range by lifting or lowering the head of the device (at least 6 metres). ° -60° Fig. 31: Transmission range Installation site Ceiling mounting in narrow rooms is not recommended.
  • Page 28: Commissioning

    Commissioning Commissioning Reducing the detection range The reduction of the detection range can be made both by means of the supplied foil or via the app. The detection angle can be specifically limited by gluing on the enclosed foil. ® The detection range of the Busch-Watchdog amounts to 90°...
  • Page 29: Changing The Lateral Detection Range

    Commissioning Changing the lateral detection range Adjust the lateral detection range as follows: 1. Adjust the lateral detection range by turning the head of the device. Fig. 34: Lateral detection range Adjusting to the hillside location To adjust the detection range to the hillside location, proceed as follows: 1.
  • Page 30: Commissioning Of The Device Via The App

    Commissioning Commissioning of the device via the app Notice Detailed information on the setting options and the operation via ABB- ® ® free@home Next App is available in the app manual for Busch-Watchdog PRO movement detectors. Activation test The activation test serves for checking the detection range by means of pacing off. A switch-off delay of two seconds is activated during the activation test, the device operates independent of brightness.
  • Page 31 Commissioning Ending the activation test The device ends the "Activation test" function under the following prerequisites: Automatically 10 minutes after the start of the activation test when the selector switch is set ■ on a desired brightness value. Manually ending the activation test: ■...
  • Page 32: Operation

    Operation Operation Operating modes at local operation Standard operation Lighting during advancing twilight remains switched on for 3 minutes after the last detection. Selector switch 6851/9-xxx-500 Selector switch 6851/22-xxx-500 6851/22S-xxx-500 Fig. 37: Standard operation Standard operation (time- and brightness dependent) Fig.
  • Page 33: Operating Modes At Operation Via The App

    The blockage can only be cancelled via the app. Operating modes at operation via the app Notice Detailed information on the setting options and the operation via ABB- free@home ® Next App is available in the app manual for Busch-Watchdog ®...
  • Page 34: Led Status Display

    Operation LED status display Fig. 40: Position of LED [1] LED Display Function Starting the device after the return of voltage, when the Blue LED - flashes twice (1 Hz) device is in factory status and has not been connected with ■...
  • Page 35: Reset (Resetting The Device)

    – Master reset via app Notice ® Local operation can be blocked via the ABB-free@home Next App. In this case both the operation and the master reset are deactivated via the selector switch on the device. The blockage can only be cancelled via the app.
  • Page 36 5 s and does not perform a master reset. Master reset via app Notice Detailed information on the setting options and the operation via ABB- free@home ® Next App is available in the app manual for Busch-Watchdog ®...
  • Page 37: Maintenance

    Maintenance Maintenance Maintenance-free device The device is maintenance-free. In case of damage, e.g. during transport or storage), do not perform repairs. Once the device is opened, the warranty is void. Access to the device must be guaranteed for operation, testing, inspection, maintenance and repairs (according to DIN VDE 0100-520).
  • Page 38 Notes Notes Product manual 2CKA000073B5790 │38...
  • Page 39 Index Index Maintenance-free device ........37 Mounting ............. 20 Activation test ..........30 Mounting method .......... 24 Cleaning ............. 37 Notes ............38 Commissioning ..........28 Notes on the instruction manual ......4 Commissioning of the device via the app ....30 Connection, installation / mounting ....
  • Page 40 Busch-Jaeger Elektro GmbH A member of the ABB Group Freisenbergstraße 2 D-58513 Lüdenscheid, Germany https://new.abb.com/en Customer service: Tel.: +49 2351 956-1600 Copyright © 2024 Busch-Jaeger Elektro GmbH All rights reserved...