  • Page 1 Supremo Thermostatic Mixer shower Fitting instructions Please note: Tap head shown is for illustration purposes only. Please keep these instructions for future reference and request of replacement parts.
  • Page 2: Table Of Contents

    We have taken great care to ensure that this product reaches you in perfect condition. However should any parts be damaged or missing please contact your point of purchase. This does not affect your statutory rights. In addition if you require replacement parts your point of purchase will be happy to assist.
  • Page 3: Tools Required

    Tools Required (Tools not supplied) Parts Supplied Description Bar valve Sealing washer Flange Adaptor Copper olives Wall Screw Wall bracket Wall plugs Sliding Bracket Riser Rail Shower head Upper Rail Rail bracket Wall Screw Fixing bracket Wall plugs Handset Shower hose Hexagonal key Grub screw...
  • Page 4: Before You Start

    Before You Start Hot water should be stored and distributed at a temperature of not less than 60°C which will help minimise the build-up of limescale. For further details contact your Local Water Authority. This shower should be installed in compliance with the UK Water(Fittings) Regulations. (a) Identify all components and check pack contents.
  • Page 5: Installation

    Installation -Fitting the Thermostatic Shower Valve 1.Flush pipe work prior to installation to remove debris from the system. 2.Turn off water supply following system flushing. 3.Mark out the position for the pipework (150mm between centres). Note: the pipe centres required for this thermostatic bar valve are 150mm.
  • Page 6 7.Holding the flat edges of the wall bracket(7) with a 48mm spanner screw the adaptors (4) onto the wall bracket(7) using a 22mm spanner.Repeat this step on both sides. 8.Screw the flange(3) over the wall bracket(7) / adaptors(4), so they are flush against the finished wall surface.
  • Page 7 -Fitting the Shower Kit 1.Using a level, measure from the central point, vertical to 703mm and mark, as shown. Ø 6mm 2.Drill and prepare fixings for the fixing bracket using the components supplied (if suitable). 3.Insert the wall plug(16), Secure the fixing bracket(15) using the supplied wall screw (14, if suitable).
  • Page 8 5.The height of the telescopic riser rail can be adjusted between 815-1270 mm, by loosening the clamp on the rail bracket(13), adjusting to the desired height and re-tightening the clamp. 6.Position the riser rail(10) assembly on the bar valve outlet,tilt the riser rail(10) back and slot the rail bracket(13) into the fixing bracket(15), hold in place by gently tightening the grub screws.
  • Page 9: Temperature Setting

    Temperature Setting (To be done only when essential) This mixer has been set in the factory under balanced pressures and hot water supply at 65°C. When your operating conditions vary significantly from the above, the temperature of the mixed water may vary from the setting. In this case,you can set the temperature of the mixer to suit your requirements.The valve is set to a maximum 44°C.This can be checked if required using a thermometer.
  • Page 10: Aftercare

    Aftercare Cleaning the thermostatic cartridge 1.Before carrying out any maintenance, turn off the mains water supply. If you are unsure contact a qualified plumber. 2.Remove the cap, grub screw, temperature handle. 3.Pull the black stop from the cartridge.Remove the retaining nut using a suitable spanner , remove and clean the thermostatic cartridge rinse thoroughly under cold water to remove any build up of limescale or debris.
  • Page 11 Cleaning the flow cartridge 1.Before carrying out any maintenance, turn off the mains water supply.If you are unsure contact a qualified plumber. 2.Remove the cap, grub screw, flow handle, 3.Remove the retaining nut using a suitable spanner, clean the diver terrise thoroughly under cold water to remove any build up of limescale or debris.
  • Page 12: General Cleaning

    General Cleaning Whilst modern plating techniques are used in the manufacture of these fittings, the plating will wear if not cleaned properly. The safest way to clean your product is to wipe with a soft damp cloth. Stains can be removed using washing up liquid. Do not use aggressive cleaning products or polishes or those which contain bleach, acids or alcohol as this may damage the surface of the product.
  • Page 13: Troubleshooting

    Increase water flow rate through the system. Instantaneous water heater incorrectly set. Check inlet filters and clean or replace. not igniting because water Refer to Aftercare section (page 10-11). flow rate is too low. Contact the boiler manufacturer. Wickes 202402 (Rev.2.0)