Download Print this page
Danfoss VLT MCB 115 Installation Manual
Danfoss VLT MCB 115 Installation Manual

Danfoss VLT MCB 115 Installation Manual

Programmable i/o
Hide thumbs Also See for VLT MCB 115:

Advertisement

Quick Links

Installation Guide
VLT® Programmable I/O MCB 115
VLT® HVAC Drive FC 102, VLT® Refrigeration Drive FC 103, VLT® AQUA
Drive FC 202, VLT® AutomationDrive FC 301/302
drives.danfoss.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the VLT MCB 115 and is the answer not in the manual?

Questions and answers

Summary of Contents for Danfoss VLT MCB 115

  • Page 1 Installation Guide VLT® Programmable I/O MCB 115 VLT® HVAC Drive FC 102, VLT® Refrigeration Drive FC 103, VLT® AQUA Drive FC 202, VLT® AutomationDrive FC 301/302 drives.danfoss.com...
  • Page 3: Table Of Contents

    Mounting the Option in Enclosure Sizes A2, A3, and B3 Mounting the Option in Enclosure Sizes A5, B1, B2, B4, C, D, E, and F Electrical Installation 3.4.1 Speci cations 3.4.1.1 Programmable Inputs 3.4.1.2 Programmable Outputs 3.4.1.3 Terminals Appendix Abbreviations Conventions Danfoss A/S © 2020.08 AN295938195323en-000201/130R0655 | 3...
  • Page 4: Introduction

    The VLT® FC Series Programming Guides provide greater detail on working with parameters. • VLT® FC Series Design Guides provide detailed capabilities and functionality to design motor control systems for various applica- tions. Technical documentation for other product options is available at www.danfoss.com. 1.5 Product Overview 1.5.1 Intended Use ®...
  • Page 5: Foreseeable Misuse

    Introduction 1.5.2 Foreseeable Misuse Any use not expressly approved by Danfoss constitutes misuse. This also applies to failure to comply with the speci ed operating conditions and applications. Danfoss assumes no liability of any sort for damage attributable to improper use.
  • Page 6: Safety

    This document gives important information on how to prevent injury and damage to the equipment or the system. Ignoring them can lead to death, serious injury, or severe damage to the equipment. Make sure to fully understand the dangers and safety measures incurred in the application. 6 | Danfoss A/S © | 2020.08 AN295938195323en-000201 / 130R0655...
  • Page 7: Installation

    Fix the extended LCP frame and terminal cover on the drive. Fit the LCP or blind cover in the extended LCP frame. Connect power to the drive. Set up the input/output functions in the corresponding parameters. Danfoss A/S © 2020.08 AN295938195323en-000201 / 130R0655 | 7...
  • Page 8: Mounting The Option In Enclosure Sizes A5, B1, B2, B4, C, D, E, And F

    Fit the option card into slot B. Connect the control cables and relieve the cable. See 3.4.1 Speci cations for wiring details. Fit the cradle on the drive. Fit the LCP in the cradle. 8 | Danfoss A/S © | 2020.08 AN295938195323en-000201 / 130R0655...
  • Page 9: Electrical Installation

    Illustration 2: Installation in Enclosure Sizes A5, B1, B2, B4, C, D, E, and F 3.4 Electrical Installation 3.4.1 Speci cations The VLT® Programmable I/O MCB 115 has 3 programmable inputs/outputs, which extend the number of inputs and outputs for the drive. Danfoss A/S © 2020.08 AN295938195323en-000201 / 130R0655 | 9...
  • Page 10: Programmable Inputs

    (32 °F) 43760) Pt1000 (according to IEC 60751) – – Accuracy Better than 1% of full scale Better than 1% of full -50 °C ±1 Kelvin scale +150 °C ±2 Kelvins 10 | Danfoss A/S © | 2020.08 AN295938195323en-000201 / 130R0655...
  • Page 11: Programmable Outputs

    Load impedance – ≥10 kΩ ≤200 Ω 3.4.1.3 Terminals There are 3 inputs and 3 outputs on the option: • Inputs: X49/1+2, X49/3+4, and X49/5+6 • Outputs: X49/7+8, X49/9+10, and X49/11+12 Danfoss A/S © 2020.08 AN295938195323en-000201 / 130R0655 | 11...
  • Page 12 VLT® Programmable I/O MCB 115 Installation Guide Installation MCB 115 OPTION B Programmable I/O 130B1266 SW. ver. xx.xx X49/ 10 11 12 Illustration 4: Terminal X49 12 | Danfoss A/S © | 2020.08 AN295938195323en-000201 / 130R0655...
  • Page 13: Appendix

    Parameter name. Parameter option. Parameter group name. Alarms/warnings. • All dimensions in drawings are in metric values (imperial values in brackets). • An asterisk (*) indicates the default setting of a parameter. Danfoss A/S © 2020.08 AN295938195323en-000201 / 130R0655 | 13...
  • Page 14 Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in speci cations already agreed. All trademarks in this material are property of the respective companies.