Programat
P200
®
Operating Instructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the Programat P200 and is the answer not in the manual?

Questions and answers

Frank Gjokaj
April 16, 2025

What does error 35 and 51 mean on my ivoclar p200

1 comments:
Mr. Anderson
April 16, 2025

Error code 35 is not listed in the provided context, so its meaning cannot be determined.

Error code 51 means there is an error in the microprocessor of the analog module. You should contact your local Ivoclar Vivadent Service Centre.

This answer is automatically generated

Summary of Contents for Ivoclar Vivadent Programat P200

  • Page 1 Programat P200 ® Operating Instructions...
  • Page 3: Table Of Contents

    Table of Contents Views of the Furnace, List of Parts Introduction / Signs and Symbols Preface Introduction 1.3. Notes regarding the Operating Instructions Safety First Indications Health and safety instructions Product Description Components Hazardous areas and safety equipment Functional description 3.4.
  • Page 5: Views Of The Furnace, List Of Parts

    List of Parts Front view Control unit keypad Furnace head with dome 50 + key / stage 2 cover 51 – key / stage 1 Sealing ring 52 Field definition Stone lining segments arrow key right Blade contacts arrow key left Thermocouple 55 0–9 Numeric keys Firing plate...
  • Page 6: Introduction / Signs And Symbols

    The Programat P200 is a Dear Customer high-tech product for dental lab Thank you for having purchased Furnace concerned: technology. It is equipped with the Programat P200. It is a Programat P200 state-of-the-art electronic highly technical quality product. Target group: components.
  • Page 7: Safety First

    2. Safety First This chapter is especially important for personnel 2.1 Indications Further instructions to assure who work with the Programat P200 or who have proper use of the furnace: to carry out maintenance or repair work. – The instructions, regulations, The Programat P200 must only be used to fire...
  • Page 8 Foreign objects must not come 2.1.5 into contact with the contact springs. Do not touch the Risks and dangers contact springs. There is a risk of electrical shock. 2.1.6 Contraindication Do not place hot items on the housing surface. There is a burn hazard.
  • Page 9 The thermocouple (5) must not be bent. Please avoid touching 2.1.9 the thermocouple (5) with your hands (oily residue on the Contraindication thermocouple).
  • Page 10: Health And Safety Instructions

    2.2 Health and Safety – Clean furnace only with a dry – Ensure that only fuses of the Warning or slightly moist cloth. Do not indicated type and rated Instructions use any solvents! Disconnect current are used. Any disruption of the protective power before cleaning.
  • Page 11: Product Description

    3. Product Description 3.1 Components 3.2 Hazardous areas and safety equipment The Programat P200 furnace system comprises the following Description of the risk areas of the furnace: components: – Furnace base with electronic controls Hazardous area Type of risk – Furnace head –...
  • Page 12: Installation And Initial Start-Up

    Do not touch missing or damaged, contact your local the heating element. Ivoclar Vivadent Customer Service. We – Clean the sealing ring (2) of the furnace recommend keeping the original packaging head. Do not touch the heating element.
  • Page 13: Initial Start-Up

    Step 2 PC or printer 4.4 Initial start-up Approximately 1 second after Connections Use a null modem cable to switching on, the furnace starts connect the furnace with a PC its automatic performance check Switching on Power connection or a printer. Connect the cable (self-diagnosis).
  • Page 14: Menu Operation And Standard Settings

    5. Menu Operation and Standard Settings Symbols used in the display Remaining time indicator 5.1 Introduction to the operation When a program is selected, the estimated time is indicated. Once a program is started, Symbol name Description Symbol The P200 is equipped with a display showing this time starts to elapse.
  • Page 15: Adjusting The Intensity Of The Background Illumination

    Close furnace head (symbol) (59) Description of the green LED (61) program has been started and the tempera- – Pressing this key results in the furnace in the START key (62) ture is 30 °C and more below the stand-by head being closed.
  • Page 16: Practical Use / Program Description

    6. Practical Use / Program Description The operating procedure for the Typical program sequence Cursor Programat P200 will be explained with the The current cursor position is shown open help of two examples: one standard and one open as usual by means of a frame and the...
  • Page 17 Indication/setting of the parameters In order to maintain the vacuum heat up, but remains at room for the first stage between the first-stage vacuum temperature. on V 1 and the second-stage vacuum off V 2 , the values for the The overnight program may first-stage vacuum off V 2 and the also be changed once the...
  • Page 18 Should you forget the code, only V2 = T (e.g. T = 1050 C, V2 = 1050 °C (the cursor is not activated). an Ivoclar Vivadent Service Center or T = 1922 °F, V2 = 1922 °F) is able to unlock the furnace.
  • Page 19: Controlling The Cte

    1. Values for S, H, and L can be 6.6 Additional practical information changed without interrupting the program sequence: – Always keep the furnace closed between – Select the desired parameter with the firings. arrow keys and enter the new value. –...
  • Page 20: Maintenance, Cleaning And Diagnosis

    Check if the thermocouple is straight and in the right place. Thermocouple (5) weekly Check the stone lining inserts for cracks and damages. If the stone linings are worn down they have to be replaced by a certified Ivoclar Vivadent Stone lining inserts (3, 6, 41) monthly Service Centre.
  • Page 21: Furnace Calibration ('Silver Test')

    (switched on for at least 60 minutes) and have a stand-by temperature of 403 °C (757 °F) (e.g. in P199). b) Insert silver wire into the Ivoclar Vivadent sample holder (see also notice enclosed in Figure B Temperature just right the Temperature Checking Set 2).
  • Page 22: What If

    8. What if … This chapter will help you to 8.1 Error messages recognize malfunctions and List of possible Error messages and their meaning take appropriate measures or, if possible and acceptable, to Operating errors perform some simple repairs. Error messages have to be acknowledged with STOP (60). Impossible values are not accepted. The value is deleted when ENTER is pressed and the ‘old’...
  • Page 23 Temperature in the furnace base is lower than 1 °C (33.8 °F). Increase the temperature in the furnace base. Further error messages *Er:71 Thermocouple defective at initialization. Contact your local Ivoclar Vivadent Service Centre (2) *Err 72 Temperature leap. Contact your local Ivoclar Vivadent Service Centre (2) *Err 73 Inadequate performance of the heater.
  • Page 24: Technical Malfunctions

    If repairs during the warranty period according to the are not carried out by a certified respective values Ivoclar Vivadent Service Centre, the specified in ‘Technical warranty will expire immediately. Data’ Please also read the safety information in Chapter 2.
  • Page 25: Product Specifications

    500 mbar to 1060 mbar 110-120 V: T 15A (heating circuit) (24) Use only original packaging of the T 500 mA (controls) (26) Programat P200 together with the T 5A (pump) (25) respective foam material for shipping purposes. Dimensions of fuses 200–240 V = Diameter 5 x 20 mm...
  • Page 26: Firing Tables / Program Tables In °C And °F

    10. Firing Tables / Program Tables in °C and °F...