Summary of Contents for Belden Telecast Fiber Systems PowerPlus 3000
Page 1
A BELDEN Brand PowerPlus 3000 and HDX SMPTE Hybrid Power System for the CopperHead™ Camera-Mountable Fiber Optic Link User Manual For All Copperhead 3000 Series Systems and the JVC FS-790 System Telecast Fiber Systems, Inc. 102 Grove Street Worcester, MA 01605...
Table of Contents Table of Contents ..............................1 List of Main Figures ............................. 2 About this User Guide ............................3 Safety and Fiber Optic Systems ........................3 Warranty ................................. 4 1. PowerPlus 3000 System ..........................5 PowerPlus Overview ............................5 PowerPlus 3000 - Camera Power Adaptor ......................
List of Main Figures FIGURE 1 - COPPERHEAD SYSTEM USING POWERPLUS AND HDX ......................5 FIGURE 2 - POWERPLUS 3000 WITH LOW PROFILE HEAT SINK MOUNTED TO COPPERHEAD CAMERA UNIT ..........6 FIGURE 3 - POWERPLUS 3000 WITH HIGH PROFILE HEAT SINK MOUNTED TO COPPERHEAD CAMERA UNIT ..........6 FIGURE 4 - POWERPLUS 3000 LED INDICATORS ............................
About this User Guide There are innumerable CopperHead system options and permutations, so not every page in this guide will apply to your specific system. Throughout this guide a number of informational pointers are used to mark important or useful information. Pointer Meaning Caution: The information provided is important safety information and should be...
Important Information Warranty LIMITED WARRANTY STATEMENT Telecast Fiber Systems, Inc. (“Telecast”) expressly warrants to Buyer that the Products supplied shall be free from defects in materials and workmanship for a period of 12 months following the date the Products are delivered to Buyer (the “Warranty Period”).
1. PowerPlus 3000 System 1.1 PowerPlus Overview The PowerPlus 3000 system is used with Telecast Fiber Systems’ CopperHead links, delivering electrical current to a video camera equipped with a CopperHead Camera Unit by adding power to a SMPTE Hybrid cable. The system consists of a camera-mountable PowerPlus adaptor at the camera, and the HDX Power Supply, located some distance away (up to 2 KM), and connected by SMPTE Hybrid cable.
1.2 PowerPlus 3000 - Camera Power Adaptor The CopperHead PowerPlus 3000 power adaptor with standard “Low Profile“ heat sink (Figure 3) provides a continuous 100 watts of 12VDC power (150 watts momentary) and fiber cable signal connectivity from Base Station to the Camera. It also provides an external power feed of 12VDC and optionally 24VDC for external accessories.
Page 9
Power Plus 3000 (cont) u 24 Volt DC “A” 24VDC is available on connector at v Power In Power is being received from the HDX power supply RED – initial safety handshaking in progress, full power not engaged. GREEN – safety handshaking completed, full power being received from HDX power supply.
1.3 HDX Power Supply The HDX Power Supply unit is required when using the PowerPlus Camera Adaptor. The HDX can be used as a free-standing unit or rack mounted, using the HDX-FR-2 for mounting one or two HDX units. The HDX unit sends power via a SMPTE hybrid fiber cable to the PowerPlus, where it is converted to 12VDC and optionally to 24VDC).
1.3.1 HDX Status Indicators AC IN - MAINS AC Input power is present DC HV ENABLE DC “Sense” voltage from PowerPlus is present AC HV ENABLE AC “Sense” voltage from PowerPlus is present (Not used with PowerPlus) HV Present DC voltage is available on Hybrid connector CABLE OPEN There is no electrical connection to the PowerPlus unit.
1.3.2 HDX Fuse Holder The correct fuses must be used for the appropriate AC Mains power supply: 115VAC: Fuse 3A, “Slo-Blo” 220VAC: Fuse 2A, “Slo-Blo” HDX Fuse Holder must be flipped if switching between 110VAC and 220VAC, as shown in Figure Figure 10 –...
1.3.3 Installing HDX into HDX-FR2 To install the HDX into the rack- mountable HDX-FR2 enclosure, first remove the eight screws shown in Figure 12. Figure 12 – HDX Screws Slide the HDX electronic module out of the sheath as shown in Figure 13. Figure 13 –...
2. Mounting the PowerPlus When mounting the CopperHead Camera Unit & PowerPlus, always position the camera so that the battery mounting plate at the rear of the camera is easy to access. Insure that the camera is well supported and stable. If a battery is mounted remove it and put it to one side. The camera model shown here is for illustrative purposes only –...
3. Connecting the SMPTE Hybrid Fiber between HDX Power Supply and Camera Unit Figure 18 - SMPTE Hybrid Fiber between the HDX Power Supply and Camera Unit Mount the PowerPlus C to the CopperHead Camera Unit A as shown in Section 2, being sure to plug the PowerPlus’...
4.1.1.3 24VDC Connectors – compatible plugs 4.1.2 HDX Power Supply Connector 4.1.2.1 AC Power Input Connector Panel Mounted AC Power Receptacle: 110/220 VAC Fuses: The removable fuse holder can hold two 1/4” x 1-1/4” (3AG) or shorter 5 x 20mm (metric) fuses. 120 VAC: Two 3 amp slo-blo fuses 220 VAC: Two 2 amp slo-blo fuses NOTE:...
4.2.2.2 HDX Unpowered Fiber Connector ST Receptacles OpticalCON Receptacle MX Receptacle 4.2.3 Important Note Regarding Use of Powered OpticalCON connector with PowerPlus & HDX System At HDX power levels (>95VDC), the powered OpticalCON connector is suitable for indoor (studio) camera links only, under specific conditions according to IEC 60664-1 “Pollution Degree 1,” where there is zero humidity, zero expected condensation and zero conductive pollution.