Yale Z-Wave Plus YRMZW2-US Installation Manual
Yale Z-Wave Plus YRMZW2-US Installation Manual

Yale Z-Wave Plus YRMZW2-US Installation Manual

Hide thumbs Also See for Z-Wave Plus YRMZW2-US:

Advertisement

Adding a Yale Z-Wave Plus™ Smart Module to your Assure Lock & Z-
Wave™ System
Please use this procedure only when the network primary controller is
missing or otherwise inoperable
1. Install the Yale Smart Module into the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open the Z-Wave system's smart home or alarm app on your smartphone or tablet
3. Follow the in-app instructions for adding a new device
4. On your lock keypad, enter your master entry code followed by the
5. Press the 7 key followed by the
6. Press the 1 key followed by the
Removing a Yale Z-Wave Plus Smart Module from your Assure Lock & Z-Wave System
1. On your lock keypad, enter your master entry code followed by the
2. Press the 7 key followed by the
3. Press the 3 key followed by the
4. Open the Z-Wave system's smart home or alarm app and follow the instructions for
removing a device
5. Remove the Yale Smart Module from the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
6. If you're adding a new Yale Smart Module, follow the instructions included with it
Trusted every day
Yale
Z-Wave Plus™ Smart
®
Module Installation Guide
icon
icon
icon
icon
P/N AYR202-ZW-INSTAL-FUL Rev F
icon
icon
Part of ASSA ABLOY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Z-Wave Plus YRMZW2-US and is the answer not in the manual?

Questions and answers

JUDITE
February 5, 2025

A bateria precisa ser trocada, acredito que a nossa da fechadura está fraca

1 comments:
Mr. Anderson
February 10, 2025

The Yale Z-Wave Plus YRMZW2-US lock may need a battery replacement if:
- The lock does not respond or shows no reaction.
- The lights dim.
- The lock chimes indicating code acceptance, but the door does not open.
- The lock operates but does not automatically re-lock.
- The low battery indicator is lit.

To resolve these issues, replace the batteries and ensure they are installed correctly. If the lock is inaccessible due to dead batteries, a 9V battery can be applied to the terminals below the keypad for backup power.

This answer is automatically generated

Summary of Contents for Yale Z-Wave Plus YRMZW2-US

  • Page 1 • Insert or remove Yale Smart Module • Reinstall batteries • Reinstall battery cover 6. If you're adding a new Yale Smart Module, follow the instructions included with it Trusted every day Part of ASSA ABLOY P/N AYR202-ZW-INSTAL-FUL Rev F...
  • Page 2 24/7 Tech Support : 1-855-492-0505 • www.US.YaleHome.com Yale is a registered trademark of Yale Home. Other products' brand names may be trademarks or registered trademarks ® of their respective owners and are mentioned for reference purposes only. © Copyright 2020. All rights reserved.
  • Page 3 • Double check door measurements • Install your Assure Lock • Program your Assure Lock • Add your Assure Lock to your smart home system or Yale Access app if purchased with Yale Smart Module or Yale Access Upgrade Kit...
  • Page 4 What's In The Box Yale Smart Module (with select models) Let's Get Started Keys Optional Installation Guide Fire Kit Parts and Door Template (Required for Fire Rated Openings) Touchscreen Keypad Loosen screw to remove cover Battery Cover Mounting Plate Inside Lock...
  • Page 5 Remove Existing Deadbolt Do not discard old lock hardware until Assure Lock has been successfully installed. Frame P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 6 Check Door Measurements And Make Adjustments If Needed Door Checker Use door checker from installation guide envelope to verify your door measurements and make any needed adjustments. Check Your Door Guide Let's Get Started New Door Marking Template With the door checker, use the template from installation guide envelope to prep a new door that has not been predrilled for hardware.
  • Page 7 Install Deadbolt and Strike Plate *2-3/8" Backset, default *Deadbolt position is based on For Deadbolt backset. Choose position Actual Size appropriate for your door. Reference Door Checker measurements E and F. AYRDB-DRIVE Adjustable Drive-In Deadbolt available for purchase *2-3/4" Backset, optional For Strike Plate Actual Size Choose...
  • Page 8 Install Touchscreen Keypad Inside of Door Outside of Door Door face hole must be at least 2-1/8". If hole is too small, a door lock installation kit or jig should be used to increase hole size. Bolt must be in retracted (unlocked) position.
  • Page 9 Install Inside Mounting Plate Actual Size optional 3 of 3 To be used with Fire Cup for Fire Rated openings P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 10 Attach Cable This Side Up mark Make sure cable is securely attached Use cable hooks for proper routing, when possible. Position wires carefully when not using hook. Do not pinch wire. P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 11 Install Inside Lock Actual Size Make sure thumbturn is vertical. If thumbturn does not move freely, refer to "Hardware Troubleshooting". P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 12 Test Mechanical Operation If thumbturn operation fails, check the installation beginning with Step 7. P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 13 Included with select models optional Inside of Door Batteries must not be installed prior to inserting and/or removing Yale Smart module. For more information about Yale Smart modules and smart home features visit US.YaleHome.com/Smart P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 14 Bolt must be in retracted (unlocked) position before installing batteries. Inside of Door Press the Yale logo to wake the lock. You will be guided through setup by audio instructions on the lock. Additional entry codes and further programming can be done through the Settings Menu.
  • Page 15 Using Your Lock Touchscreen Keypad Press to wake keypad or lock door Location of RFID Signal Receiver Press to return to (YRD620/YRD622 ACC ONLY) previous Settings Menu Press to enter Enter Master Entry Code or unlock and press to access Settings Menu Low Battery All Code Lockout...
  • Page 16 Creating Master Entry Code The Master Entry Code is used to change lock settings. A security best practice is to set your Master Entry Code with 6 or more digits and create a separate code that is used daily to lock and unlock the door. "Register Master Code.
  • Page 17 Creating Entry Codes Master Entry Code must be created first. *Max Entry Codes = 250 with Smart Module; 25 without. "Menu Mode, press the gear key Enter Master to continue." Entry Code Press Press Press Enter 4-8 digit Entry Code Press Press Press...
  • Page 18 Deleting Entry Codes "Menu Mode, enter number, press the gear key Enter Master to continue." Entry Code Press Press Press Press Press Deleting one Entry Code: To delete all Entry Codes: To delete one Entry Code, (Does not delete you must enter the Entry Master Entry Code) Code you wish to delete.
  • Page 19 Unlocking Door with Entry Codes Enter Entry Code Press Unlocking Door with RFID (YRD620/YRD622 ACC ONLY) See "Customizing YRD620/YRD622 Lock Using Settings Menu", page 20 to configure RFID communication. Touch and hold fob or card to P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 20 Setting Definitions Settings Default Setting Definition The Master Entry Code is used for programming and feature settings. It must be created prior to Creation Master Entry Code required* programming the lock. The Master Entry Code will also operate (unlock/lock) the lock. This feature is enabled by the Master Entry Code.
  • Page 21 Here is an example of how to set Auto Lock to 30 seconds: Master Entry Code *The Master Entry Code must be created prior to any other programming of the lock. **Network Module Setting function appears only with Yale Smart module installed. P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 22 Customizing YRD620/YRD622 ACC ONLY Lock Using Settings Menu *Master Entry Code Required 1. Press Yale logo to wake up lock 2. Enter Master Entry Code* followed by icon. Lock Response: "Welcome to the Settings Menu. Press each number to hear available settings and then press the settings icon to enter."...
  • Page 23 Troubleshooting Symptom Suggested Action Keypad becomes active when the Yale logo is pressed. • Verify contact with the logo. If keypad numbers are visible, check they respond when pressed. • Lock does not respond – Check batteries are installed and oriented correctly (polarity) in battery case.
  • Page 24 1. Remove plate from door frame with a manual screwdriver. (Using an electric driver may strip screw For help with misalignments, watch our door alignment heads or enlarge screw holes.) video: US.YaleHome.com/en/support/yale-assure-lock- faqs/electronic-lock-installation/ P/N YRD226-MNL-0001 Rev J Part of ASSA ABLOY...
  • Page 25 Resetting Lock to Factory Defaults When lock is reset to factory defaults all Entry Codes (including the Master Entry Code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove battery cover and batteries. 2.
  • Page 26 Ÿ Consult the dealer or an experienced radio/TV technician for help. Ÿ Warning: Changes or modifications to this device, not expressly approved by Yale Home could void the user's authority to operate the equipment. Industry Canada: IC ID : 11626A-YRD622BLEV1 This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
  • Page 27 Yale Locks Z-Wave Plus™ System Integrators Guide Yale Assure Deadbolt Lock YRD216-ZW2, YRD226-ZW2, YRD256-ZW2, YRC216-ZW2, YRC226-ZW2, YRC256-ZW2, YRD136-ZW2, YRD137-ZW2, YRD156-ZW2, YRD157-ZW2 NF-YRD612-ZW2, YRD652-ZW2, NF-YRD622-ZW2, YRD622-ZW2, YRD642-ZW2, NF-YRC612-ZW2, YRC652-ZW2, NF-YRC622-ZW2, YRC622-ZW2, YRC642-ZW2...
  • Page 28: Table Of Contents

    Contents Yale Z-Wave Plus Product Info ........................3 Supported Command Classes ........................4 Association Table ............................4 Notifications Table ............................5 Configurable Parameters ..........................7 * Command Class Requires Security...
  • Page 29: Yale Z-Wave Plus Product Info

    0x12C4 for YRC642-ZW2 (2nd Generation Fire Rated Keyless Interconnected Touch Screen Deadbolt)  0x3AD3 for YRD137-ZW2 (2nd Generation Yale Residential PRO SL Push Button Deadbolt Lock)  0x3AD5 for YRD157-ZW2 (2nd Generation Yale Residential PRO SL Touch Screen Deadbolt Lock) Product Type ID: ...
  • Page 30: Supported Command Classes

    Supported Command Classes Command Class Z-Wave Plus Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery* Command Class Door Lock* Command Class Door Lock Logging* Command Class Schedule Entry Lock* Command Class User Code* Command Class Time Parameters* Command Class Time*...
  • Page 31: Notifications Table

    Notifications Table Alarm Alarm Reports Alarm Level Description type 0x00 Master code was changed at keypad Master Code changed. 0xFB Master code was changed over RF 0x70 0x(01-max User added User added. Alarm level = user slot number users) 0x(01-max User deleted 0x21 User was deleted.
  • Page 32 Enabled/Disabled users) ** - The Yale Assure Deadbolt locks also supports a 3 low battery alarm, too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF) through the Battery Command Class. This is the last...
  • Page 33: Configurable Parameters

    Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent mode on/off 1 1 byte Silent. Default is 2 or Low Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 10 to 180 seconds default is 30 seconds...