Fireplace Requirements; Fireplace Converted Tag - Travis Industries Lopi Radiant Plus MV Medium Owner's Manual

Insert
Table of Contents

Advertisement

8
Installation (for qualified installers only)

Fireplace Requirements

Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-
built (metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert may use an optional circulation blower, clean the fireplace, smoke shelf, and
chimney prior to installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
f
a
e

Fireplace Converted Tag

The fireplace must be permanently marked to indicate that it has been altered and is no longer suitable
for burning solid fuel (wood) unless the removed parts are replaced and the fireplace fully inspected and
approved. Attach the "This fireplace has been converted..." tag to the fireplace (use two screws or other
suitable method). You may wish to place it in a location where it will be covered by the surround panels
or face.
© Travis Industries
b
c
d
8/2/2018 - 1446
Fireplace Sizing
a
Minimum Height
b
Minimum Width
c
Minimum Depth
d
Hearth Extension
The gas line should be installed prior to
e
installing the heater.
For tight fits (under 28") see the section
f
h
"Removing the Vent Connector"
g
g
See "Leveling Legs" for details on leveling
the heater.
h
Fireplace Converted Tag (see details
below)
19-3/4" (502mm)
27" (686mm)
15" (381mm)
0" (0mm)
Radiant Medium MV

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lopi Radiant Plus MV Medium and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Lopi radiant plus mv small

Table of Contents