All personal information you provided will be only used for warranty service and kept strictly confidential. Refer to this list when contacting GATEXPERT for technical service or assistance with your automatic gate opener. Order Number Product Model...
Instructions for SW300DC Dear users, Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you send this product to a third party. 1. Safety Instruction Please read this manual carefully before installation, in which involves with important ...
Instructions for SW300DC Packing List (Optional) Picture Name Quantity Infrared sensor Wireless keypad Alarm lamp Electric lock Storage battery Due to the difference of installation environment, our company does not provide the installation accessories to fix and connect gate openers and wall. Please prepare the these installation accessories according to actual site situation.
Instructions for SW300DC 4. Installation Drawing Figure 1 SW300DC swing gate opener is applicable to single leaf gate weight less than 300kg, and 2.5m. The drive mode adopts planetary transmission to the length shorter than combine with the screw rod transmission. This gate opener must be installed inside the enclosure or yard for protection.
Instructions for SW300DC 6. Cable List Cable Application Cable Material Max. Length Cable of 220V controlbox’s power 3×2.5mm² (>30m) Unlimited supply 3×1.5mm² (<30m) Cable of gate opener’s power supply 2×1.5mm² Cable of infrared sensor 2×0.5mm² Cable of alarm lamp 2×0.5mm²...
One PVC pipe for motor and power cables, the other one for control cables. 8.1.2 Mounting Brackets Fixing In order to install the SW300DC main machines firmly, it is recommended to use the expansion screws to fix the mounting brackets. 8.2 Accessory Installation A) Before installing the main machines, please install the wall bracket on the wall first, then fix the connecting bracket, finally install the front mounting bracket on the gate.
Page 11
Instructions for SW300DC B) The connecting bracket and the wall bracket can be connected according to different conditions, please refer to figure 5. Figure 5 C) Before the installation, please unlock the two main machines. Unlock method: Open the manual release cover, insert the manual release key, rotate the key until it’s released, as shown in Figure 6, then turn the telescopic arm, you’ll find it’s stretched...
Instructions for SW300DC Figure 8 Figure 9 8.3 Dimension of Control Box Figure 10 www.gatexpertstore.com...
Page 13
Instructions for SW300DC Note To ensure safety and protect the machines, please install a gate stopper at the open limit position when the gate opens outward to prevent the gate from running over its travel. Meanwhile, to enable the 2 swings to close to its accurate limit position, please install a limit stopper at the closed limit position (as shown in figure 3).
Instructions for SW300DC 21. COM Common 9.3 Digital Screen Setting When the control board is working, the users can check working state of gate opener by digital screen on the control board. : no input; : under opening state; : under closing state;...
Instructions for SW300DC 9.4.2 Hall Limit mode learning trip (double door) 1. Open both sides of the door body to the middle position and lock the clutch, and then long press the "-" button on the control panel until the digital tube shows "SU"...
Instructions for SW300DC 3. Switch the niB to Step B. Press + or - to move the control door 1 to the closing position and then press PROG to confirm. 4. After the digital tube displays "OK", the initial interface "--" is entered, indicating the completion of trip learning.
Instructions for SW300DC Press and hold "+" button, the alarm light will keep flashing, and digital screen displays remote control mode -- “PO” -- two swing gates single channel mode; “Pd" -- single gate four channel mode; Press the button of the remote control to be learned, the digital screen will show the number of current learned remote control, then the remote control learning is completed.
Page 20
Instructions for SW300DC Single gate mode 3 seconds (default) Open gate time interval 15 seconds (default) Automati c closing time Dual gates single channel Remote mode control mode Four channel Single gate single channel Delete remote www.gatexpertstore.com...
Instructions for SW300DC 9.7.2 Base Menu Instruction Menu Option Default/Attention Press "PROG" to Press “+”(up) or “-”(down) to select; enter into base menu. Press “SET” to confirm. Standard mode; O/C/S (Open/Close/Stop). O/S/C standard mode with automatic closing function. When the gate opens, it will automatically close after automatic closing time.
Page 22
Instructions for SW300DC Dual gates mode(default). Dual gates Single Gate/Dual mode. Gates Switch Single gate mode. 00-10: Open gate time interval is 0-15 seconds(default 3 seconds). If Open Gate Time 3 seconds. the interval shorter than 2 seconds, Interval then the electric lock cannot be used.
Instructions for SW300DC 9.7.3 Advanced Menu Instruction Long press "PROG" 2 seconds to enter into advanced menu. Digital Screen shows “TL”, press “+”(up) or “-”(down) to select; Short press “SET” to confirm or to enter into sub-menu. Short press “PROG” to exit.
Page 24
Instructions for SW300DC Electric lock normally off Alarm lamp normally on Alarm lamp Alarm lamp normally flash consumption mode on consumpti on mode consumption mode off Stop block Limit switch Hall mode sensor SW400DC Gate opener secection SW300DC SW200DC Default...
Instructions for SW300DC 9.7.4 Advanced Menu Instruction Menu Option Default/Attention Long press "PROG" 2 Press “+”(up) or “-”(down) to select; seconds to enter into Press “SET” to confirm. base menu. Time of of gate1 After automatic learning, if the stroke is not ideal, it can be adjusted manually.
Page 26
Instructions for SW300DC Low consumption mode on.The control board will automatically enter low-consumption mode after one Low consumption mode minute when there is no operation at Low Consumption the initial screen. (Default) Mode Low consumption mode off. Stop block.(Default) Stop block.
Instructions for SW300DC 10. Others 10.1 Maintenance Check whether the gate operates normally every month. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required as well. Before installation and operation of the gate opener, please read all instructions carefully.
Instructions for SW300DC appropriately 1. Check the infrared setting status Infrared disconnect 2. Whether there are occlusions in the infrared Door 1 closes before door 1. Relearn your itinerary 2.Adjust the opening time interval 1. Check whether you have The motor works for too...
Page 29
Instructions for SW300DC Power supply line short circuit Leakage switch tripped. Check wiring. or motor line short circuit. Remote control working Connect external receiver antenna, Signal is blocked. distance is too short. 1.5 meters above ground. 1.Motor output force is not 1.Check whether the transformer...